id:
|
||||
aliases: []
|
||||
tags:
|
||||
- destiny/permanent
|
||||
- occupational/systems
|
||||
- status/draft
|
||||
- type/guide
|
||||
title: Misc Budgets
|
||||
---
|
||||
# Misc Budgets
|
||||
|
||||
## Slab Deck
|
||||
|
||||
```
|
||||
Drawing = "N/A"
|
||||
Area = "Typical - ..."
|
||||
System = "EL - Electrical"
|
||||
```
|
||||
|
||||
Create `Area` Typicals for every concrete slab floor:
|
||||
|
||||
* 'All Building'
|
||||
* 1 each level except roof
|
||||
* **HD:** 1 per Section
|
||||
|
||||
```
|
||||
Phase = "Building - BOH, Storage & Common"
|
||||
```
|
||||
|
||||
* 'All Garage'
|
||||
* 1 each level
|
||||
|
||||
```
|
||||
Phase = "Garage"
|
||||
```
|
||||
|
||||
In each Typical:
|
||||
|
||||
* Takeoff: `ITEM DATABASE`/`MISC PDI PRODUCT`/`MISC MATERIAL - SLAB/DECK & FEEDER`/`MISC MATERIAL - SLAB/DECK (NAILS, PAINT, TAPE, ETC = $250)`
|
||||
* 1 Takeoff each Typical
|
||||
* _Count_ = 1
|
||||
|
||||
## Temporary Power & Lighting
|
||||
|
||||
### Temp Power
|
||||
|
||||
```
|
||||
Area = "2 - Site"
|
||||
Phase = "Temp Power"
|
||||
System = "TPS - Temp Power Service (Site)"
|
||||
BidItem = "1 - Site"
|
||||
```
|
||||
|
||||
* Takeoff: `ITEM DATABASE`/`TEMPORARY POWER`/`TEMPORARY POWER - ... SERVICE`
|
||||
|
||||
### Temp Lighting (Building)
|
||||
|
||||
```
|
||||
Area = "01 - Temp Power Distribution Building"
|
||||
Phase = "Temp Power"
|
||||
System = "TPD - Temp Power Distribution (Gag. & Bldg.)"
|
||||
BidItem = "3 - Building"
|
||||
```
|
||||
|
||||
Garden Styles:
|
||||
* Takeoff: `ITEM DATABASE`/`TEMPORARY POWER`/`TEMPORARY POWER - T POLE (EACH)`
|
||||
* _Count_ = 1 per 150ft per building
|
||||
|
||||
All others:
|
||||
* Takeoff: `ITEM DATABASE`/`TEMPORARY POWER`/`* - TEMPORARY LIGHTING / PWR PNL (PER BLDG AREA SFT)`
|
||||
* _Count_ = Building GSF = Total GSF - Garage GSF
|
||||
|
||||
### Temp Lighting (Garage)
|
||||
|
||||
```
|
||||
Area = "01 - Temp Power Distribution Garage"
|
||||
Phase = "Temp Power"
|
||||
System = "TPD - Temp Power Distribution (Gag. & Bldg.)"
|
||||
BidItem = "2 - Garage"
|
||||
```
|
||||
|
||||
* Takeoff: `ITEM DATABASE`/`TEMPORARY POWER`/`* - TEMPORARY LIGHTING / PWR PNL (PER BLDG AREA SFT)`
|
||||
* _Count_ = Garage GSF
|
||||
|
||||
## Irrigation Pumps
|
||||
|
||||
```
|
||||
Area = "2 - Site"
|
||||
Phase = "Temp Power"
|
||||
System = "MISC - Site Miscellaneous"
|
||||
BidItem = "1 - Site"
|
||||
```
|
||||
|
||||
Takeoff: `COMMON ASSEMBLIES`/`MECHANICAL CONNECTIONS (UP TO 100A)`/`PVC - LT NM FLEX (CARFLEX)`/`30A 3PH MECH CONN (200') 3/4" PVC 4#10 - CARFLEX`
|
||||
* _Count_ = 3
|
||||
* Prepend to name: "Irrigation Pumps - "
|
||||
Reference in New Issue