@@ -24,7 +24,8 @@ aliases:
Determine which Systems and Codes are required:
* _IBC/IECC 2021 or later:_ all fixtures 0-10V dimmable.
* `System` = "LV - Lighting Control System"
> [!info] Breakdowns
> * `System` = "LV - Lighting Control System"
## Wall Switches
@@ -72,27 +73,29 @@ Room controllers distributed throughout controlled areas.
`COMMON ASSEMBLIES`/`SWITCHES`/`LOW VOLTAGE SWITCHES & OCC SENSORS - ROUGH IN`/...
1. .../`DLM LTG RM CONTROLLER - ...`
**Count:** each lighting control zone.
* **Count:** each lighting control zone.
2. .../`REC PLUG CONTROLLER - ...`
**Count:** each receptacle control zone.
* **Count:** each receptacle control zone.
3. `HEATING`/`Network Bridge - Blank 4SQ`
**Count:** each controller.
* **Count:** each controller.
Coordinate with PDS to determine if necessary.
4. `COMMON ASSEMBLIES`/`PDI BRANCH CKT HOME RUNS`/... (_without_ dimming cable)
**Count:** each _circuit_.
* **Count:** each _circuit_.
### "Centralized" Systems
Zones switched and dimmed from central lighting control panel (LCP).
1. `COMMON ASSEMBLIES`/`DISTRIBUTION`/`LIGHTING CONTROL PANEL INSTALLATION`/...
1. `COMMON ASSEMBLIES`/`PDI BRANCH CKT HOME RUNS`/... (_with_ dimming cable)
* **Count:** each _lighting control zone_.
2. `COMMON ASSEMBLIES`/`PDI BRANCH CKT HOME RUNS`/... (_with_ dimming cable)
**Count:** each _lighting control zone_.
#### "Feed-Thru" Panels
1. `COMMON ASSEMBLIES`/`DISTRIBUTION`/`LIGHTING CONTROL PANEL INSTALLATION`/`_ - LIGHTING CONTROL PANEL INSTALLATION & TROUGH - ...`
### Somewhere In Between
@@ -103,8 +106,8 @@ assumes zones will be controlled either
I think just as common is 3--5 circuit controllers above the ceiling.
1. `HEATING`/`Lighting Control Room Controller - n Circuit`
**Count:** each controller.
* **Count:** each controller.
2. `COMMON ASSEMBLIES`/`PDI BRANCH CKT HOME RUNS`/... (_without_ dimming cable)
**Length:** route to room.
**Count:** each circuit.
* **Length:** route to room.
* **Count:** each circuit.