diff --git a/new-additions/takeoff/lighting-controls.md b/new-additions/takeoff/lighting-controls.md index 2ac5c89..2f141e5 100644 --- a/new-additions/takeoff/lighting-controls.md +++ b/new-additions/takeoff/lighting-controls.md @@ -12,6 +12,22 @@ All control methods are likely to appear in drawings. > [!info] "Local Control" > The term "local control only" is sometimes used to indicate no condiseration > for *any* lighting control beyond standard devices, -> (with dimmers being the triac type) +> (with $Ds being the triac type) > however, this phrasing is ambiguous and non-universal. > Confirm with the bid team on what must be included. + +## Custom Switch Boxes + +For switch combinations not in `COMMON ASSEMBLIES`, +create heating designations based on the most similar. + +### Naming + +#### Format + +```regex + - (\: )?( - )? \(\)( )* ft +``` + +> [!example] +> `A - Surface: Pendant - 2.0hrs (MC) LV 20ft` diff --git a/new-additions/takeoff/lighting.md b/new-additions/takeoff/lighting.md index 1953a1e..abd2f07 100644 --- a/new-additions/takeoff/lighting.md +++ b/new-additions/takeoff/lighting.md @@ -1,8 +1,34 @@ -# Lighting Takeoff +# Lighting Takeoff (Fixtures) -## Fixtures +## Naming -### Fixture Labor +### Format + +```regex + - (\: )?( - )? \(\)( )* ft +``` + +> [!example] +> `A - Surface: Pendant - 2.0hrs (MC) LV 20ft` + +### Order + +Use empty designations to separate phases. + +> [!example] +> ``` +> *** Hotel Units *** +> HU - Surface (MC) LV 20ft +> HU - Surface - 1.5hrs (MC) LV 20ft +> HU - Surface: Pendant - 2.0hrs (MC) LV 20ft +> HU - Surface: J-Box For Future Fixture (MC) LV 20ft +> HU - Recessed (MC) LV 20ft +> *** Condo Units *** +> CU - Surface: Tape - 1.0hrs (MC) LV 25ft +> CU - Surface: Wall (MC) LV 25ft +> ``` + +## Fixture Labor > | Fixture Type | Labor | > | ------------ | -------------- | @@ -15,7 +41,7 @@ > > [^1]: Determine exact labor from fixture and size. -### Fixture Branch Length +## Fixture Branch Length > | Case | Standard Length | > | ------------- | --------------- | @@ -32,7 +58,7 @@ > > [^2]: See fixture types below for special cases. -### Fixture Branch Wire size +## Fixture Branch Wire size > | Case | Wire Size | > | -------------- | --------- | @@ -45,9 +71,9 @@ > > [^2]: Kitchen and bathroom fixtures shall be #12 (NOT #14) on wood frame (NM) projects. -### Garage +## Garage -#### Fixtures +### Fixtures Use ENT Assembly unless spec requires otherwise. @@ -61,7 +87,7 @@ If PVC, use following assemblies: | Ceiling | `PVC/ENT ASSEMBLIES`/`... - SLAB BOX / 45 DEG STUBBY` | | Wall | `PVC/ENT ASSEMBLIES`/`... - STL BOX & TILE RING / 45 DEG STUBBY/ ENT DROP` | -#### Homeruns +### Homeruns > `System` = "EL - Electrical" @@ -69,7 +95,7 @@ Use 1 Homerun for every 3 circuits in Garage Use assembly `Common Assemblies`/`Device Homeruns in Slab/Deck` -### Surface Mount +## Surface Mount * Wall Mount (Sconce) * Pendant @@ -88,7 +114,7 @@ Use assembly `Common Assemblies`/`Device Homeruns in Slab/Deck` > [!note] > Use lighting control cable assemblies in Amenity areas -#### Tape Lighting +### Tape Lighting Also called "cove" or "strip", however those terms are less specific @@ -128,7 +154,7 @@ A - Tape 9.5hr (109-114ft) - MC #12 40ft A - Tape 10.0hr (115-120ft) - MC #12 40ft ``` -### Recessed +## Recessed * recessed downlight * recessed linear @@ -147,7 +173,7 @@ round up to the nearest 5ft > [!note] > "HI HAT" refers to a recessed can fixture. -### Undercabinet Fixtures +## Undercabinet Fixtures | Wiring Method | Assembly Path | | ------------- | ------------------------------------- | @@ -159,7 +185,7 @@ round up to the nearest 5ft Use 10ft #12/2 for MC & NM -### Paddle Fans +## Paddle Fans | Wiring Method | Assembly Path | | ------------- | ----------------------------------------------------- | @@ -167,11 +193,11 @@ Use 10ft #12/2 for MC & NM | MC Cable | `MC ASSEMBLIES`/`FAN RATED OCT BOX W/ BAR HNGR - ...` | | PVC | `PVC/ENT ASSEMBLIES`/`... - SLAB BOX / 45 DEG STUBBY` | -### Stairwells & Elevators +## Stairwells & Elevators `PVC/ENT ASSEMBLIES`/`... - SLAB BOX / 45 DEG STUBBY` -### Facade +## Facade > `Phase` = "Facade" @@ -185,24 +211,24 @@ Length and Labor will be more than a normal fixture in BOH/Amenity > 1. `3/4" PVC W/ 3#10 - STL BOX & TILE RING / 45 DEG STUBBY/ ENT DROP` > * `Length per Unit` = Distance to panel -### Porte Cochere (Drive up Area) +## Porte Cochere (Drive up Area) Create its own breakout in WBS, and phase in Accubid This is not technically exposed or drop ceiling, but still use PVC -### FAA Lighting +## FAA Lighting > 1. `FIXTURE LABOR`/`FIXTURE LABOR 1HR` > 2. `FESTOON & ROOF ASSEMBLIES`/`Aircraft Warning, 3/4" Conduit GRC/PVC 2#10, 1#10G` -## Site & Courtyard +# Site & Courtyard -### Breakdowns +## Breakdowns > `System` = "FML - Site Fixtures Material & Labor" -### Fixture Assemblies +## Fixture Assemblies > | Fixture Type | Assembly Path | > | ------------------------------------ | -------------------------------------------------------------------------------- | @@ -217,7 +243,7 @@ This is not technically exposed or drop ceiling, but still use PVC > > [^2]: Per Corwin: Hand rail lights should have a rigid 90 stub up and some flex -#### Festoon Lighting +### Festoon Lighting AKA "string" or "market" lights