title: IBC Construction Types
|
||||
---
|
||||
# IBC Construction Types
|
||||
|
||||
The International Building Code (IBC)
|
||||
lists 5 major construction types based on fire ratings/materials.
|
||||
|
||||
## 5-Over-1 Construction
|
||||
|
||||
"5-over-1" construction denotes a building
|
||||
with levels of combustible construction
|
||||
above levels of non-combustible construction.
|
||||
|
||||
buildings with two non-combustible levels (5-over-2)
|
||||
and Type III upper floors (3-over-1)
|
||||
are also common,
|
||||
though "5-over-1" denotes the general practice.
|
||||
|
||||
## Type I: Fire Resistive Non-Combustible
|
||||
|
||||
Building elements are noncombustible[^1]
|
||||
|
||||
[^1]: Defined as passing the test procedures
|
||||
for defining combustibility of elementary materials
|
||||
set forth in ASTM E 136
|
||||
|
||||
* Concrete, masonry, noncombustible steel
|
||||
|
||||
### Type I-A: Protected Fire-Resistive Non-Combustible
|
||||
|
||||
Common of [[pdi-building-types#High Rise]] and Group I occupancies.
|
||||
|
||||
* 3hr Exterior Walls
|
||||
* 3hr Structural Frame
|
||||
* 2hr Floor/Ceiling Assembly
|
||||
* 1.5hr Roof Protection
|
||||
|
||||
### Type I-B: Unprotected Fire-Resistive Non-Combustible
|
||||
|
||||
Common of mid-rise office & Group R buildings.
|
||||
|
||||
* 2hr Exterior Walls
|
||||
* 2hr Structural Frame
|
||||
* 2hr Ceiling/Floor Separation
|
||||
* 1hr Ceiling/Roof Assembly
|
||||
|
||||
## Type II: Non-Combustible
|
||||
|
||||
Same materials as [[#Type I Fire-Resistive Non-Combustible]],
|
||||
with reduced fire-resistance requirements.
|
||||
|
||||
Common of [[pdi-building-types#Mid Rise]] buildings.
|
||||
|
||||
### Type II-A: Protected Non-Combustible
|
||||
|
||||
Common of [[pdi-building-types#High Density]],
|
||||
including dormitory buildings.
|
||||
|
||||
* 1hr Exterior Walls
|
||||
* 1hr Structural Frame
|
||||
* 1hr Floor/Ceiling/Roof Protection
|
||||
|
||||
### Type II-B: Unprotected Non-Combustible
|
||||
|
||||
Common of [[pdi-building-types#Commercial]].
|
||||
|
||||
## Type III: Combustible
|
||||
|
||||
Also known as "ordinary" construction.
|
||||
|
||||
Exterior walls are of noncombustible materials.
|
||||
Interior building elements may be combustible.
|
||||
|
||||
### Type III-A: Protected Combustible
|
||||
|
||||
Common of [[pdi-building-types#High Density]].
|
||||
|
||||
* 2hr Exterior Walls
|
||||
* 1hr Structural Frame
|
||||
* 1hr Floor/Ceiling/Roof Protection
|
||||
|
||||
### Type III-B: Unprotected Combustible
|
||||
|
||||
Common of "warehouse" districts of older cities.
|
||||
|
||||
* 2hr Exterior Walls
|
||||
|
||||
## Type IV: Heavy Timber
|
||||
|
||||
Also known as "mill" construction.
|
||||
|
||||
Exterior walls are of noncombustible materials.
|
||||
Interior building elements are of solid or laminated wooden members
|
||||
with a minimum nominal dimension of 8 inches
|
||||
without concealed spaces.
|
||||
|
||||
* 2hr Exterior Walls
|
||||
* 1hr Structural Frame or Heavy Timber Heavy Timber Floor/Ceiling/Roof Assemblies
|
||||
|
||||
## Type V: Wood Frame
|
||||
|
||||
Construction materials are of any allowed by code,
|
||||
combustible or noncombustible.
|
||||
|
||||
Common of garden or above podiums
|
||||
|
||||
### Type V-A: Protected Wood Frame
|
||||
|
||||
Commonly used in the construction of newer apartment buildings.
|
||||
There is no exposed wood visible.
|
||||
|
||||
* 1hr Exterior Walls
|
||||
* 1hr Structural Frame 1hr Floor/Ceiling/Roof
|
||||
|
||||
### Type V-B: Unprotected Wood Frame
|
||||
|
||||
Common of single family homes.
|
||||