@@ -12,7 +12,7 @@ because its single advantage over reference class forecasting
|
|||||||
is in itemized pricing,
|
is in itemized pricing,
|
||||||
but this advantage is nullified
|
but this advantage is nullified
|
||||||
by the known phenomenon that the precise
|
by the known phenomenon that the precise
|
||||||
selection of particular items and their quantities
|
selection of particular items and their quantities
|
||||||
can not be trusted to be exactly accurate
|
can not be trusted to be exactly accurate
|
||||||
due to uncertainty of project conditions,
|
due to uncertainty of project conditions,
|
||||||
and by the observation that material pricing at the time of bid
|
and by the observation that material pricing at the time of bid
|
||||||
@@ -22,7 +22,7 @@ The inevitable retort is
|
|||||||
"It's an *est*imate, not an *exact*imate,"
|
"It's an *est*imate, not an *exact*imate,"
|
||||||
or some other such reductive dismissal.
|
or some other such reductive dismissal.
|
||||||
True enough, this method is _a_ way
|
True enough, this method is _a_ way
|
||||||
of getting close to the true answer of project cost and schedule,
|
of _getting close_ to the true answer of project cost and schedule,
|
||||||
but it's not an intuitive one.
|
but it's not an intuitive one.
|
||||||
|
|
||||||
For an organizational process to be economical
|
For an organizational process to be economical
|
||||||
|
|||||||
@@ -15,21 +15,24 @@ daily: "[[2026-05-28]]"
|
|||||||
~~not shown on mech, plumbing, otherwise~~
|
~~not shown on mech, plumbing, otherwise~~
|
||||||
~~despite Keynote 4 "SEE MECHANICAL WATER PIPING DIAGRAM FOR EXACT LOCATIONS OF PUMPS."~~
|
~~despite Keynote 4 "SEE MECHANICAL WATER PIPING DIAGRAM FOR EXACT LOCATIONS OF PUMPS."~~
|
||||||
~~We could assume that these are intended for the pool equipment~~
|
~~We could assume that these are intended for the pool equipment~~
|
||||||
~~and delete the takeoff.~~
|
~~and delete the takeoff.~~[^1]
|
||||||
|
|
||||||
> M3.00, being a diagram, does not show exact locations,
|
[^1]: M3.00, being a diagram, does not show exact locations,
|
||||||
> _but does show the pumps being used for domestic water._
|
_but does show the pumps being used for domestic water._
|
||||||
> (Also the diagram suggests
|
(Also the diagram suggests
|
||||||
> that the pumps may be spread much far than implied by Electrical,
|
that the pumps may be spread much far than implied by Electrical,
|
||||||
> that our takeoff may be missing a large amount of cable.)
|
that our takeoff may be missing a large amount of cable.)
|
||||||
> (Also four water heaters are shown
|
(Also four water heaters are shown
|
||||||
> which were not shown on electrical.)
|
which were not shown on electrical.)
|
||||||
|
|
||||||
|
SP400 shows an electrical panel Keynote 16
|
||||||
|
|
||||||
|
> [!quote] SP400 Keynote 16
|
||||||
|
> NOT SHOWN ON PLANS.
|
||||||
|
> PROVIDE DISCONNECTS IF PANEL IS NOT IN EQUIPMENT ROOM.
|
||||||
|
> IF ELECTRICAL PANEL IS LOCATED IN EQUIPMENT ROOM,
|
||||||
|
> THEN THE PANEL MUST BE NEMA-4X RATED...
|
||||||
|
|
||||||
SP400 shows an electrical panel Keynote 16
|
|
||||||
"NOT SHOWN ON PLANS.
|
|
||||||
PROVIDE DISCONNECTS IF PANEL IS NOT IN EQUIPMENT ROOM.
|
|
||||||
IF ELECTRICAL PANEL IS LOCATED IN EQUIPMENT ROOM,
|
|
||||||
THEN THE PANEL MUST BE NEMA-4X RATED..."
|
|
||||||
No panel schedule is provided.
|
No panel schedule is provided.
|
||||||
|
|
||||||
SP400 Pool Equipment Room is not shown
|
SP400 Pool Equipment Room is not shown
|
||||||
@@ -38,8 +41,10 @@ It is not shown enclosed, even on the Spa set.
|
|||||||
It seems like the Spa set was done last
|
It seems like the Spa set was done last
|
||||||
with no coordination with other disciplines.
|
with no coordination with other disciplines.
|
||||||
|
|
||||||
With no other information I'd assume PVC, LFMC, and NEMA 4X disconnects to all equipment shown on SP400
|
> With no other information
|
||||||
from the Garage panels.
|
> I'd assume PVC, LFMC, and NEMA 4X disconnects
|
||||||
|
> to all equipment shown on SP400
|
||||||
|
> from the Garage panels.
|
||||||
|
|
||||||
Water Feature plans are a similar case.
|
Water Feature plans are a similar case.
|
||||||
|
|
||||||
@@ -53,5 +58,9 @@ Water Feature plans are a similar case.
|
|||||||
Neither [[jared-defanti]] nor I am satisfied with this answer.
|
Neither [[jared-defanti]] nor I am satisfied with this answer.
|
||||||
This would mean excluding a significant number of connections.
|
This would mean excluding a significant number of connections.
|
||||||
|
|
||||||
> [!quote] [[joel-jansen]] 2026-05-28 13:10 (pp.)
|
Around 13:10 we spoke to [[joel-jansen]] about the issues.
|
||||||
>
|
He tended to agree with us
|
||||||
|
that the drawings suggested the EC would be responsible for more,
|
||||||
|
but said he would confirm with [[christian-pereiro]].
|
||||||
|
|
||||||
|
Christian directed us to respect Komis's direction.
|
||||||
|
|||||||