From 640ccf0b020cb414b3d62f0a8c95e47e61cc638d Mon Sep 17 00:00:00 2001 From: Zane Meyers Date: Mon, 9 Mar 2026 16:50:11 -0400 Subject: [PATCH] vault backup: 2026-03-09 16:50:11 --- 463-davison-ave-ne.md | 10 +- timestamped/2026-03-09_15-50-49.md | 190 +++++++++++++++++++++++++++++ 2 files changed, 198 insertions(+), 2 deletions(-) create mode 100644 timestamped/2026-03-09_15-50-49.md diff --git a/463-davison-ave-ne.md b/463-davison-ave-ne.md index 6641b44..b69ce7a 100644 --- a/463-davison-ave-ne.md +++ b/463-davison-ave-ne.md @@ -23,9 +23,15 @@ Policy Number: ATH1143034 Flood Insurance: Insurer: [National General](https://eservice.nationalgeneral.com/) -Policy Number: 0003457855] +Policy Number: 0003457855 -## Contractors +## Resources + +### Websites + +[South Florida Plant Guide](https://www.south-florida-plant-guide.com/) + +### Contractors * **HVAC:** Agape Air (semiannual service) * **Plumbing:** Hafke Plumbing diff --git a/timestamped/2026-03-09_15-50-49.md b/timestamped/2026-03-09_15-50-49.md new file mode 100644 index 0000000..e5d5be1 --- /dev/null +++ b/timestamped/2026-03-09_15-50-49.md @@ -0,0 +1,190 @@ +--- +id: 2026-03-09T15:50:49-04:00 +aliases: [] +title: 2026-03-09 15:50:49 +tags: + - authorship/original + - destiny/permanent + - status/draft + - type/timestamped +daily: "[[2026-03-09]]" +date-created: 2026-03-09T15:50:49-04:00 +dg-publish: true +monthly: "[[2026-03]]" +quarterly: "[[2026-Q1]]" +weekly: "[[2026-W11]]" +yearly: "[[2026]]" +--- +# 2026-03-09 15:50:49 + +%% Implementation of [[conest-pre-takeoff-email-template]] %% + +Hello Team, + +Below is a comprehensive list of means & methods for Charlotte South End Hotel. +Please confirm you have received this email and respond with any questions or comments. + +* **Delivery Method:** Plans & Specs +* **Document Stage:** Issue for Permit +* **Drawings Date:** 2026-02-27 +* **Project Manual Date:** 2026-02-27 +* **Proposal Date:** 2025-12-12 +* **Takeoff Request Stage:** Full Takeoff + +### Project Specification Callouts + +* **Conduit:** + %% GRC, coupling specs, etc. %% + +* **Wire:** + * Material: Aluminum 100A and larger _---E021 "ALUMINUM FEEDER SCHEDULE" Note 1(b)_ + * Acceptable Manufacturers: _---Spec 260510-2 (p. 2224)_ + * Encore Wire + * General Cable + * Okonite + * Paranite + * Pirelli + * Senator + * Southwire + +* **MC Cable:** + * Application: Concealed feeders and branch circuits _---Spec XXXXXX (p. XXXX)_ + %% Branch homeruns only; Not permitted %% + * Acceptable Manufacturers: _---Spec 260510-2 (p. 2224)_ + * Alflex + * AFC + * America Metal Moulding + * Encore Wire + * Southwire + * ==Conductors: Copper _---Spec XXXXXX (p. XXXX)_== + * ==Armor: Steel _---Spec XXXXXX (p. XXXX)_== + * ==Jacket: PVC _---Spec XXXXXX (p. XXXX)_== + +* **Steel Box Depth:** + * Telecom: 2-1/8" _---Spec XXXXXX (p. XXXX)_ + * Security: 2-1/8" _---Spec XXXXXX (p. XXXX)_ + * Other Applications: Not specified + %% 1-1/2", 2-1/8" %% + +* **Floor Boxes:** Sheet metal with brass or aluminum covers _---Spec XXXXXX (p. XXXX)_ + +* **Wiring Devices:** + * Units: + * Current rating: Unspecified. Assuming 15A for takeoff. + * Standard/Decora: Unspecified. Assuming Toggle/Duplex for takeoff. + %% 15A Decora %% + * BOH/Common Areas: + * Current rating: Unspecified. Assuming 20A for takeoff. + * Standard/Decora: Unspecified. Assuming Toggle/Duplex for takeoff. + %% 20A Toggle/Duplex %% + +* **Switchboards:** + * Acceptable Manufacturers: _---Spec XXXXXX (p. XXXX)_ + * ??? + * Bus Material: ??? _---Spec XXXXXX (p. XXXX)_ + * Interrupting Current Rating: ??? + +* **Distribution Panelboards:** + * Acceptable Manufacturers: _---Spec XXXXXX (p. XXXX)_ + * ??? + * Bus Material: ??? _---Spec XXXXXX (p. XXXX)_ + * Breaker Types: ??? _---Spec XXXXXX (p. XXXX)_ + %% Snap-on, bolt on %% + * Interrupting Current Rating: ??? + +* **Load Centers:** + * Acceptable Manufacturers: _---Spec XXXXXX (p. XXXX)_ + * ??? + * Bus Material: ??? _---Spec XXXXXX (p. XXXX)_ + * Breaker Types: ??? _---Spec XXXXXX (p. XXXX)_ + %% Snap-on, bolt on %% + * Interrupting Current Rating: ??? + +* **Transformers:** + * Winding Material: ??? _---Spec XXXXXX (p. XXXX)_ + * K-Rating: ??? + %% Windings AL or CU, K-rating %% + +* **Generator:** (1) 500kW Diesel + * Enclosure Specs: ??? _---Dwg. E014_ + * Remote Tank: ??? + * Tank Size: ??? _---Spec XXXXXX (p. XXXX)_ + * Load Banks: ??? _---Spec XXXXXX (p. XXXX)_ + * Acceptable Manufacturers: _---Spec 263213-3 (p. 2323)_ + * Caterpillar Tractor Co. + * Cummins/Power Generation + * Kohler Power Systems (MTU Engine Only) + * MTU On-Site Energy + +### Project Drawing/Detail Callouts + +* Describe conflicts between drawings / proposal: + %% "Plans show CU feeders, proposal calls for aluminum", Specification grade devices, etc. %% + +* Cost drivers in details not shown elsewhere on plans: + +### PDI System Execution Plan + +* **Primaries:** + %% Installation only, (9) 6" PVC %% + +* **Secondaries:** + * + %% PVC UG, GRC Stub-ups, AL %% + +* **Feeders:** + PVC UG, EMT OH; + Size and material per E05-10 schedule + ==(Transformer primaries and secondaries all copper)== + %% PVC UG, EMT OH, AL over 100A, 2% VD %% + %% Emergency Feeds MI Cable %% + +* **Unit Subfeeds:** ??? + %% MC OH AL, VD per Chart on E5.01 %% + +* **Units:** + * ??? + %% 15A Decora, Disposals, T-stat, Floor Boxes, Shade Control, Doorbells, Dimmer Switches, etc. %% + +* **Telecom:** + * ??? + %% 42" MSDE, No Cable Homeruns, (1) 1" Back to IDF, CAT6 with Stub-ups %% + +* **EV Chargers:** ??? + %% (42) Conduit only, (56) Conduit & Wire, (20) Conduit, Wire & Equipment %% + +* **Fire Alarm:** ??? + %% Free-air where allowed by code. EMT Risers. %% + +* **DAS:** ??? + %% Conduit only, Per PDI DAS Design %% + +* **Low Voltage:** Free-air where allowed by code. + %% Free-air where allowed by code. Stub-ups to accessible ceilings. %% + +### Lighting Control + +* **Basis of Takeoff:** ??? _---???_ + %% Code Minimum per Energy Code Assigned, P&S, PDI Design %% + +* **Area:** _---Dwg. E06-01 "LIGHTING CONTROL NARRATIVE"_ + * + %% Assign Method to Areas: Line Voltage, Low-Voltage Stand Alone or Centralized System %% + +### Tasks/Quotes Needed for WBS + +%% Delete any completed %% + +* Electrical Constructability Review +* Electrical VDC +* Coordination Study +* DAS Public Safety Raceway Design + + + +Thank you,