diff --git a/.obsidian/plugins/recent-files-obsidian/data.json b/.obsidian/plugins/recent-files-obsidian/data.json index edadd0e..6abe92f 100644 --- a/.obsidian/plugins/recent-files-obsidian/data.json +++ b/.obsidian/plugins/recent-files-obsidian/data.json @@ -1,5 +1,25 @@ { "recentFiles": [ + { + "basename": "feeders", + "path": "feeders.md" + }, + { + "basename": "full-takeoff", + "path": "full-takeoff.md" + }, + { + "basename": "material-pricing", + "path": "material-pricing.md" + }, + { + "basename": "switchgear", + "path": "switchgear.md" + }, + { + "basename": "README", + "path": "README.md" + }, { "basename": "open-problems-in-estimating", "path": "open-problems-in-estimating.md" @@ -8,14 +28,6 @@ "basename": "portable-tools", "path": "portable-tools.md" }, - { - "basename": "README", - "path": "README.md" - }, - { - "basename": "feeders", - "path": "feeders.md" - }, { "basename": "low-voltage", "path": "low-voltage.md" @@ -28,10 +40,6 @@ "basename": "electrical", "path": "electrical.md" }, - { - "basename": "full-takeoff", - "path": "full-takeoff.md" - }, { "basename": "feeder-sizing", "path": "feeder-sizing.md" @@ -60,10 +68,6 @@ "basename": "assembly-objects", "path": "assembly-objects.md" }, - { - "basename": "switchgear", - "path": "switchgear.md" - }, { "basename": "bpm-award-analysis", "path": "bpm-award-analysis.md" @@ -195,10 +199,6 @@ { "basename": "blank-system", "path": "blank-system.md" - }, - { - "basename": "subfeeds", - "path": "subfeeds.md" } ], "omittedPaths": [], diff --git a/feeders.md b/feeders.md index 99b8676..07baf93 100644 --- a/feeders.md +++ b/feeders.md @@ -68,12 +68,14 @@ Locate: > All takeoffs in Systems with names including "site" > should be in "Site" Area, Phase, and Bid Item breakdowns. +For adjacent panels, use a minimum 10ft length. + #### Adders Use the difference in elevation between equipment or 10ft, whichever is greater. -Add an additional 5ft for site runs +Add an additional 5ft (total 15ft) for site runs (primaries, secondaries, etc.). #### Primaries @@ -82,14 +84,18 @@ Empty conduit. #### Secondaries -> [!info] Vaults and Secondary Connections -> In utility vaults, secondary conductors sometimes run on racks, -> far past their entrance conduits, to their transformers. -> It is necessary to add this distance to the wire makeup, -> rather than simply measure the conduit assembly to the transformer. +##### Wiring on Vault Racks + +Where secondary conductors run on racks in utility vaults +manually set the length of conduit, +measure the wire length, +add 20ft in addition to previously mentioned adders. #### Feeders +`Area` = "01 - Feeders/Risers Building" +for all feeders, no matter the location. + #### Bus Duct `COMMON ASSEMBLIES`/`DISTRIBUTION`/`BUS DUCT` diff --git a/full-takeoff.md b/full-takeoff.md index f2f3acd..9b533a3 100644 --- a/full-takeoff.md +++ b/full-takeoff.md @@ -35,3 +35,5 @@ Complete [[project-setup]]. 11. [[misc-budgets]] ### 3. Extension (Review and Checking) + +1. [[material-pricing]] diff --git a/material-pricing.md b/material-pricing.md new file mode 100644 index 0000000..d86e8fa --- /dev/null +++ b/material-pricing.md @@ -0,0 +1,43 @@ +--- +id: +aliases: [] +tags: + - occupational +--- +# Material Pricing + +## Info + +Use PDI and another vendor per the table below. +PDI pricing takes precedence where available. + +| State | Vendor | +| ----- | ----------------------------- | +| AZ | QED INC - 12535 | +| CA | QED INC - 12535 | +| CO | QED INC - 12535 | +| DC | CAPITAL ELECTRIC - 14302 | +| DE | CAPITAL ELECTRIC - 14302 | +| FL | WORLD ELECTRIC SUPPLY - 45223 | +| GA | WORLD ELECTRIC SUPPLY - 34243 | +| MD | CAPITAL ELECTRIC - 14302 | +| NC | WORLD ELECTRIC SUPPLY - 34243 | +| NJ | COOPER ELECTRIC - 34860 | +| NY | COOPER ELECTRIC - 34860 | +| PA | CAPITAL ELECTRIC - 14302 | +| SC | WORLD ELECTRIC SUPPLY - 34243 | +| TN | WORLD ELECTRIC SUPPLY - 34243 | +| TX | QED INC - 12535 | +| VA | CAPITAL ELECTRIC - 14302 | +| WA | QED INC - 12535 | + +> [!important] +> When updating, uncheck Update Supplier Code. + +## Sequence + +### 1. Estimate preparation + +### 2. Takeoff + +### 3. Extension (Review and Checking) diff --git a/switchgear.md b/switchgear.md index a1e3748..67d099a 100644 --- a/switchgear.md +++ b/switchgear.md @@ -14,7 +14,7 @@ tags: 2. In the drawings, locate: * Riser Diagrams * House Panels -3. Copy over default Temporary Assemblies from ? +3. Copy over default Temporary Assemblies from sandbox job ### 2. Takeoff @@ -38,7 +38,6 @@ tags: * Meter * Fire Pump * Fire Pump Controller - * SPD/TVSS When building panelboards/switchboards, add terminations according to an example from the schedules. @@ -52,6 +51,14 @@ Items to Avoid: * Grounding * Elevator Room +#### SPD's/TVSS's + +Labor only: ~1.5hrs + +#### Panelboards + +`DISTRIBUTION`/`DIST PANELS & UNIT LOAD CENTERS`/... + #### Enclosed Circuit Breakers Treat as disconnect switch.