# Distribution Designations
|
||||
|
||||
## Naming
|
||||
|
||||
> [!example]
|
||||
> ```
|
||||
> Generator - 350kW, Diesel
|
||||
> Generator - 2000kW, Diesel
|
||||
> ATS - 200A
|
||||
> ATS - 250A
|
||||
> ATS - 400A
|
||||
> ATS - 600A
|
||||
> ATS - 800A
|
||||
> ATS - 1000A
|
||||
> Panelboard - 50A, 1-Section
|
||||
> Panelboard - 100A, 1-Section
|
||||
> Panelboard - 125A, 1-Section
|
||||
> Panelboard - 150A, 1-Section
|
||||
> Panelboard - 225A, 1-Section
|
||||
> Panelboard - 225A, 2-Section
|
||||
> Panelboard - 400A, 1-Section
|
||||
> Panelboard - 400A, 2-Section
|
||||
> Panelboard - 400A, 3-Section
|
||||
> Panelboard - 600A, 2-Section
|
||||
> Panelboard - 800A, 1-Section
|
||||
> Panelboard - 1200A, 1-Section
|
||||
> Panelboard - 1200A, 2-Section
|
||||
> Panelboard - 3000A, 1-Section
|
||||
> CT Cabinet
|
||||
> Power Monitor
|
||||
> SPD/TVSS
|
||||
> ```
|
||||
|
||||
## Content
|
||||
|
||||
### Terminations
|
||||
|
||||
When building
|
||||
* [[#Panelboards]]
|
||||
* [[#Switchboards]]
|
||||
add **branch terminations** according to an example from the schedules.
|
||||
**Do not include feeder terminations.**
|
||||
|
||||
## By Equipment Type
|
||||
|
||||
> [!tip] When in Doubt
|
||||
> If the equipment is not listed below,
|
||||
> use a distribution panel of equal amps.
|
||||
|
||||
### CT Cabinets
|
||||
|
||||
???
|
||||
|
||||
### SPD's/TVSS's
|
||||
|
||||
> Name = "SPD"
|
||||
|
||||
Labor only.
|
||||
|
||||
Specific item is not important, but I use
|
||||
`SPLITTERS / SOCKETS / CABINETS`/`METER SOCKETS & CABINETS`/`METERING CURRENT TRANSFORMER`
|
||||
(Labor = 1.5hrs)
|
||||
for consistency.
|
||||
|
||||
### Submeters/Power Monitors
|
||||
|
||||
> Name = "Power Monitor"
|
||||
|
||||
See [[switchgear#SPD's/TVSS's]]
|
||||
|
||||
### Switchboards
|
||||
|
||||
> Name = "Switchboard - 2000A, 4-Section"
|
||||
|
||||
### Panelboards
|
||||
|
||||
> Name = "Panelboard - 600A, 2-Section"
|
||||
|
||||
`DISTRIBUTION`/`DIST PANELS & UNIT LOAD CENTERS`/...
|
||||
|
||||
### Disconnects and Enclosed Circuit Breakers
|
||||
|
||||
`COMMON ASSEMBLIES`/`DISTRIBUTION`/`MANUAL DISCONNECTS`/...
|
||||
|
||||
### Generators
|
||||
|
||||
> Name = "Generator - 250kW, Diesel"
|
||||
|
||||
Add `DISTRIBUTION FITTINGS`/`GENERATOR SET UP`.
|
||||
|
||||
### Generator Connection Cabinets
|
||||
|
||||
> Name = "GCC - 200A"
|
||||
|
||||
Use a Distribution Panel of equal amps.
|
||||
Or a transfer switch.
|
||||
|
||||
### Transfer Switches
|
||||
|
||||
> Name = "Transfer Switch - 400A"
|
||||
|
||||
#### Transfer Switches 1200A+
|
||||
|
||||
Use 1200A and add an additional `TRANSFER SWITCH` item
|
||||
to make up the remaining amps.
|
||||
|
||||
### Meter Centers
|
||||
|
||||
> Name = "Meter Center - 800A, 16-Can"
|
||||
|
||||
`SWITCHGEAR & METER CENTERS`/`METER CENTERS`/`... METERING SECTION`
|
||||
|
||||
Adjust Factor 1 for meter stacks, delete zeroed items.
|
||||