# Switchgear
|
||||
|
||||
> [!info]
|
||||
> See [[distribution-equipment]].
|
||||
|
||||
1. Build Items in Distribution:
|
||||
* Panelboards
|
||||
* Switchboards
|
||||
* Meter centers
|
||||
* Generators
|
||||
* Transfer switches
|
||||
* Generator connection cabinets
|
||||
* CT cabinets
|
||||
* Power monitor
|
||||
1. Build [[distribution-designations|designations]]
|
||||
|
||||
2. Takeoff Common Assemblies:
|
||||
* XFMRs
|
||||
* Disconnect switches
|
||||
|
||||
3. Takeoff Items in Item Database:
|
||||
* Wireway (Trough/Gutter)
|
||||
|
||||
4. Takeoff Temp Assemblies:
|
||||
* Fire Pump
|
||||
* Fire Pump Controller
|
||||
|
||||
When building panelboards/switchboards,
|
||||
add terminations according to an example from the schedules.
|
||||
**Do not include feeder terminations.**
|
||||
2. Takeoff riser scope, including designations and assemblies.
|
||||
|
||||
> [!important] Scope to Exclude
|
||||
> * Tap Boxes
|
||||
@@ -47,69 +26,21 @@ add terminations according to an example from the schedules.
|
||||
> * Grounding
|
||||
> * Elevator Room
|
||||
|
||||
## By Equipment Type
|
||||
## Takeoff
|
||||
|
||||
> [!tip] When in Doubt
|
||||
> If the equipment is not listed below,
|
||||
> use a distribution panel of equal amps.
|
||||
* `Area` = _As shown_
|
||||
* `Phase` = "Switch Gear"
|
||||
* `System` = "SWG - Switchgear"
|
||||
* `Bid Item` = "3 - Building"
|
||||
|
||||
### SPD's/TVSS's
|
||||
### Transformers
|
||||
|
||||
> Name = "SPD"
|
||||
1. `COMMON ASSEMBLIES`/`DISTRIBUTION`/`TRANSFORMERS`/...
|
||||
|
||||
Labor only.
|
||||
### Disconnects
|
||||
|
||||
Specific item is not important, but I use
|
||||
`SPLITTERS / SOCKETS / CABINETS`/`METER SOCKETS & CABINETS`/`METERING CURRENT TRANSFORMER`
|
||||
(Labor = 1.5hrs)
|
||||
for consistency.
|
||||
1. `COMMON ASSEMBLIES`/`DISTRIBUTION`/`MANUAL DISCONNECTS`/...
|
||||
|
||||
### Submeters/Power Monitors
|
||||
### Wireway
|
||||
|
||||
> Name = "Power Monitor"
|
||||
|
||||
See [[switchgear#SPD's/TVSS's]]
|
||||
|
||||
### Switchboards
|
||||
|
||||
> Name = "Switchboard - 2000A, 4-Section"
|
||||
|
||||
### Panelboards
|
||||
|
||||
> Name = "Panelboard - 600A, 2-Section"
|
||||
|
||||
`DISTRIBUTION`/`DIST PANELS & UNIT LOAD CENTERS`/...
|
||||
|
||||
### Disconnects and Enclosed Circuit Breakers
|
||||
|
||||
`COMMON ASSEMBLIES`/`DISTRIBUTION`/`MANUAL DISCONNECTS`/...
|
||||
|
||||
### Generators
|
||||
|
||||
> Name = "Generator - 250kW, Diesel"
|
||||
|
||||
Add `DISTRIBUTION FITTINGS`/`GENERATOR SET UP`.
|
||||
|
||||
### Generator Connection Cabinets
|
||||
|
||||
> Name = "GCC - 200A"
|
||||
|
||||
Use a Distribution Panel of equal amps.
|
||||
Or a transfer switch.
|
||||
|
||||
### Transfer Switches
|
||||
|
||||
> Name = "Transfer Switch - 400A"
|
||||
|
||||
#### Transfer Switches 1200A+
|
||||
|
||||
Use 1200A and add an additional `TRANSFER SWITCH` item
|
||||
to make up the remaining amps.
|
||||
|
||||
### Meter Centers
|
||||
|
||||
> Name = "Meter Center - 800A, 16-Can"
|
||||
|
||||
`SWITCHGEAR & METER CENTERS`/`METER CENTERS`/`... METERING SECTION`
|
||||
|
||||
Adjust Factor 1 for meter stacks, delete zeroed items.
|
||||
1. `ITEM DATABASE`/???
|
||||
|
||||