@@ -12,11 +12,16 @@ Direction from [[joel-jansen|Joel]]
|
||||
|
||||
[[telecom-takeoff#Corridor Conduit (IDF to Unit MSDE)]]
|
||||
|
||||
It is acceptable to use a weighted average length
|
||||
It is acceptable to use a weighted average of subfeed length
|
||||
in a "Typical - All Units"
|
||||
in lieu of individual takeoffs per floor.
|
||||
|
||||
## Unit Condensing Units
|
||||
|
||||
[[electrical-takeoff#Unit Condensing Units]]
|
||||
For [[electrical-takeoff#Unit Condensing Units|unit CU takeoff]], in most cases
|
||||
the horizontal length should **not** be the subfeed length,
|
||||
but the distance from the unit panel to the indoor unit.
|
||||
|
||||
This assumes the riser can be routed up an interior wall,
|
||||
rather than a single chase for all units (worst case)
|
||||
assumed by the subfeed length heuristic.
|
||||
|
||||