# Fire Alarm
|
||||
|
||||
## Info
|
||||
|
||||
## Sequence
|
||||
|
||||
### 1. Estimate preparation
|
||||
@@ -24,25 +25,23 @@ tags:
|
||||
|
||||
### 2. Takeoff
|
||||
|
||||
#### Riser
|
||||
#### Fire Command Center
|
||||
|
||||
##### Fire Command Center
|
||||
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`HEAD END EQUIP`/`... HEAD END`
|
||||
|
||||
{Building Type} Head End CA.30.23.X
|
||||
#### Generator Room
|
||||
|
||||
##### Generator Room
|
||||
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`GENERATOR ROOM ...`
|
||||
|
||||
CA.30.22.2
|
||||
#### Fire Pump Room
|
||||
|
||||
##### Fire Pump Room
|
||||
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`FIRE PUMP ROOM ...`
|
||||
|
||||
CA.30.22.4
|
||||
#### FACR to Elevator Shafts
|
||||
|
||||
##### FACR to Elevator Shafts
|
||||
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`ELEV SHAFT ...`
|
||||
|
||||
Elevator Shafts (CA.30.22.8)
|
||||
|
||||
FACR TO ELEV SHAFT 1 ½" (CA.30.22.10/11)
|
||||
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`FACR TO ELEV SHAFT ...`
|
||||
|
||||
Measure Length from the most distant points of the FACR and each shaft.
|
||||
Input adder length to reach the bottom of the pit
|
||||
@@ -57,25 +56,27 @@ Input adder length to reach the bottom of the pit
|
||||
| | |
|
||||
```
|
||||
|
||||
##### FACR to Elevator Control Rooms
|
||||
#### FACR to Elevator Control Rooms
|
||||
|
||||
Elevator Control Room (CA.30.22.6)
|
||||
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`ELEV CONTROL ROOM ...`
|
||||
|
||||
FACR/FCC TO ELEV CONTROL ROOM (CA.30.22.13/14)
|
||||
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`FACR TO ELEV CONTROL RM ...`
|
||||
|
||||
* Measure the Horizontal and Vertical Distance from the FACR to the ECR.
|
||||
* Use Typicals for the vertical riser. (Ex// 10' per floor)
|
||||
* Add [[sleeving]] as necessary.
|
||||
|
||||
##### FACR to Stairwells
|
||||
#### FACR to Stairwells
|
||||
|
||||
FACR TO STAIRWELLS 1" PVC (CA.30.22.17)
|
||||
This is for the Flow/Tamper modules in the stairwells
|
||||
|
||||
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`FACR TO STAIRWELLS ...`
|
||||
|
||||
* Measure from the furthest end of FACR to the furthest end of the stairwell to find length
|
||||
|
||||
* This is for the Flow/Tamper modules in the stairwells
|
||||
|
||||
##### Terminal Cabinets
|
||||
#### Terminal Cabinets
|
||||
|
||||
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`TERMINAL CABINET`
|
||||
TERMINAL CABINETS (2) 2" EMT/PVC (CA.30.26.X)
|
||||
|
||||
Horizontal:
|
||||
@@ -83,45 +84,38 @@ Horizontal:
|
||||
|
||||
Vertical:
|
||||
* Use 10ft Riser in Typical
|
||||
* GA or HD - 1" conduit / HR - (2) 2" conduits)
|
||||
* *Garden Style or High Density:* 1" conduit / HR - (2) 2" conduits)
|
||||
* Add [[sleeving]] as necessary.
|
||||
|
||||
##### Annunciator Panels
|
||||
#### Annunciator Panels
|
||||
|
||||
* Fire Alarm Annunciator (FAA),
|
||||
* Fire Alarm Annunciator Panel (FAAP)
|
||||
> [!info] Also Known As
|
||||
> * Fire Alarm Annunciator (FAA)
|
||||
> * Fire Alarm Annunciator Panel (FAAP)
|
||||
|
||||
ANNUNCIATORS (CA.30.27.2/3)
|
||||
|
||||
Remote Serial Annunciator, LCD Display - PVC
|
||||
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`ANNUNCIATORS`/`REMOTE SERIAL ANNUNCIATOR ...`
|
||||
|
||||
* Measure from the Fire Command Room to FAA or Lobby
|
||||
|
||||
##### Sleeving
|
||||
|
||||
#### Devices
|
||||
|
||||
1. Takeoff floor plans in order
|
||||
2. Takeoff enlarged drawings
|
||||
|
||||
##### Smoke Detectors
|
||||
#### Smoke Detectors
|
||||
|
||||
_Design Build:_
|
||||
Count every stairwell at every level.
|
||||
|
||||
##### Pull Stations
|
||||
#### Pull Stations
|
||||
|
||||
_Design Build:_
|
||||
Count every stairwell at every level
|
||||
and every exterior exit.
|
||||
|
||||
##### Flow-Tamper Switches
|
||||
#### Flow-Tamper Switches
|
||||
|
||||
No free air. if wood frame, take off as EMT.
|
||||
|
||||
_Design Build:_
|
||||
Count every stairwell at every level.
|
||||
|
||||
##### Magnetic Door Holders
|
||||
#### Magnetic Door Holders
|
||||
|
||||
Mech Connection - PVC AL Flex - 20 A
|
||||
|
||||
@@ -129,7 +123,7 @@ _Design Build:_
|
||||
Count every set of double doors.
|
||||
(Typical of elevator lobbies and corridors)
|
||||
|
||||
##### Speaker Strobes
|
||||
#### Speaker Strobes
|
||||
|
||||
_Design Build:_
|
||||
* Count every 75 ft,
|
||||
@@ -139,10 +133,26 @@ _Design Build:_
|
||||
* every elevator lobby,
|
||||
* and every BOH room on the first floor and garage levels.
|
||||
|
||||
#### Firefighter Phone System
|
||||
|
||||
* firefighter phone jacks
|
||||
* fire warden station
|
||||
* fire phone cabinet
|
||||
|
||||
Communicates directly with FACR.
|
||||
Not related to responder radio.
|
||||
|
||||
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`COMMUNICATION DEVICES ...`/`...`
|
||||
|
||||
#### Fire Smoke Dampers (FSD's)
|
||||
|
||||
Take off both FA and Electrical
|
||||
* Misc Assemblies
|
||||
Take off both FA
|
||||
|
||||
`COMMON ASSEMBLIES`/`MISC ASSEMBLIES`/`FSD ...`
|
||||
|
||||
and Electrical
|
||||
|
||||
`COMMON ASSEMBLIES`/`MECHANICAL CONNECTIONS (UP TO 100A)`/.../...
|
||||
|
||||
### 3. Extension (Review and Checking)
|
||||
|
||||
|
||||