# Fire Alarm
## Info
## Sequence
### 1. Estimate preparation
@@ -24,25 +25,23 @@ tags:
### 2. Takeoff
#### Riser
#### Fire Command Center
##### Fire Command Center
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`HEAD END EQUIP`/`... HEAD END`
{Building Type} Head End CA.30.23.X
#### Generator Room
##### Generator Room
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`GENERATOR ROOM ...`
CA.30.22.2
#### Fire Pump Room
##### Fire Pump Room
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`FIRE PUMP ROOM ...`
CA.30.22.4
#### FACR to Elevator Shafts
##### FACR to Elevator Shafts
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`ELEV SHAFT ...`
Elevator Shafts (CA.30.22.8)
FACR TO ELEV SHAFT 1 ½" (CA.30.22.10/11)
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`FACR TO ELEV SHAFT ...`
Measure Length from the most distant points of the FACR and each shaft.
Input adder length to reach the bottom of the pit
@@ -57,25 +56,27 @@ Input adder length to reach the bottom of the pit
| | |
```
##### FACR to Elevator Control Rooms
#### FACR to Elevator Control Rooms
Elevator Control Room (CA.30.22.6)
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`ELEV CONTROL ROOM ...`
FACR/FCC TO ELEV CONTROL ROOM (CA.30.22.13/14)
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`FACR TO ELEV CONTROL RM ...`
* Measure the Horizontal and Vertical Distance from the FACR to the ECR.
* Use Typicals for the vertical riser. (Ex// 10' per floor)
* Add [[sleeving]] as necessary.
##### FACR to Stairwells
#### FACR to Stairwells
FACR TO STAIRWELLS 1" PVC (CA.30.22.17)
This is for the Flow/Tamper modules in the stairwells
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`FACR TO STAIRWELLS ...`
* Measure from the furthest end of FACR to the furthest end of the stairwell to find length
* This is for the Flow/Tamper modules in the stairwells
##### Terminal Cabinets
#### Terminal Cabinets
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`TERMINAL CABINET`
TERMINAL CABINETS (2) 2" EMT/PVC (CA.30.26.X)
Horizontal:
@@ -83,45 +84,38 @@ Horizontal:
Vertical:
* Use 10ft Riser in Typical
* GA or HD - 1" conduit / HR - (2) 2" conduits)
* *Garden Style or High Density:* 1" conduit / HR - (2) 2" conduits)
* Add [[sleeving]] as necessary.
##### Annunciator Panels
#### Annunciator Panels
* Fire Alarm Annunciator (FAA),
* Fire Alarm Annunciator Panel (FAAP)
> [!info] Also Known As
> * Fire Alarm Annunciator (FAA)
> * Fire Alarm Annunciator Panel (FAAP)
ANNUNCIATORS (CA.30.27.2/3)
Remote Serial Annunciator, LCD Display - PVC
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`ANNUNCIATORS`/`REMOTE SERIAL ANNUNCIATOR ...`
* Measure from the Fire Command Room to FAA or Lobby
##### Sleeving
#### Devices
1. Takeoff floor plans in order
2. Takeoff enlarged drawings
##### Smoke Detectors
#### Smoke Detectors
_Design Build:_
Count every stairwell at every level.
##### Pull Stations
#### Pull Stations
_Design Build:_
Count every stairwell at every level
and every exterior exit.
##### Flow-Tamper Switches
#### Flow-Tamper Switches
No free air. if wood frame, take off as EMT.
_Design Build:_
Count every stairwell at every level.
##### Magnetic Door Holders
#### Magnetic Door Holders
Mech Connection - PVC AL Flex - 20 A
@@ -129,7 +123,7 @@ _Design Build:_
Count every set of double doors.
(Typical of elevator lobbies and corridors)
##### Speaker Strobes
#### Speaker Strobes
_Design Build:_
* Count every 75 ft,
@@ -139,10 +133,26 @@ _Design Build:_
* every elevator lobby,
* and every BOH room on the first floor and garage levels.
#### Firefighter Phone System
* firefighter phone jacks
* fire warden station
* fire phone cabinet
Communicates directly with FACR.
Not related to responder radio.
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`COMMUNICATION DEVICES ...`/`...`
#### Fire Smoke Dampers (FSD's)
Take off both FA and Electrical
* Misc Assemblies
Take off both FA
`COMMON ASSEMBLIES`/`MISC ASSEMBLIES`/`FSD ...`
and Electrical
`COMMON ASSEMBLIES`/`MECHANICAL CONNECTIONS (UP TO 100A)`/.../...
### 3. Extension (Review and Checking)