vault backup: 2026-01-07 17:01:31
This commit is contained in:
+39
-13
@@ -11,29 +11,35 @@ title: PDI Breakdowns
|
||||
---
|
||||
# PDI Breakdowns
|
||||
|
||||
## Bid Item: Site
|
||||
## Location
|
||||
|
||||
### Bid Item: Site
|
||||
|
||||
* `Bid Item` = "1 - Site"
|
||||
* `Area` = "2 - Site"
|
||||
* `Phase` = "Site"
|
||||
|
||||
## Bid Item: Garage
|
||||
### Bid Item: Garage
|
||||
|
||||
* `Bid Item` = "2 - Garage"
|
||||
* `Area` = "XX - Level XX Garage"
|
||||
* `Phase` = "Garage"
|
||||
|
||||
## Bid Item: Building
|
||||
#### Area: Stairwells Garage
|
||||
|
||||
* `Area` = "S - Stairwells Garage"
|
||||
|
||||
### Bid Item: Building
|
||||
|
||||
* `Bid Item` = "3 - Building"
|
||||
|
||||
### Owner
|
||||
#### Owner
|
||||
|
||||
#### Area: Building
|
||||
##### Area: Building
|
||||
|
||||
* `Area` = "XX - Level XX Building"
|
||||
|
||||
##### Phase: Back of House (BOH)
|
||||
###### Phase: Back of House (BOH)
|
||||
|
||||
* `Phase` = "Building - Back of House (BOH)"
|
||||
|
||||
@@ -42,11 +48,16 @@ Catch all for spaces not
|
||||
* all bathrooms
|
||||
* owner offices
|
||||
|
||||
##### Phase: Corridor
|
||||
###### Phase: Corridor
|
||||
|
||||
* `Phase` = "Building - Corridor"
|
||||
|
||||
#### Area: Interior Amenity
|
||||
###### Phase: Units
|
||||
|
||||
* `Area` = "Typical - Unit A"
|
||||
* `Phase` = "UNIT - ..."
|
||||
|
||||
##### Area: Interior Amenity
|
||||
|
||||
* `Area` = "XX - Level XX Interior Amenity Building"
|
||||
* `Phase` = "Interior Amenity"
|
||||
@@ -69,7 +80,7 @@ Also includes
|
||||
* meeting rooms
|
||||
* event spaces
|
||||
|
||||
#### Area: Kitchen
|
||||
##### Area: Kitchen
|
||||
|
||||
* `Area` = "XX - Level XX Kitchen Building"
|
||||
* `Phase` = "Kitchen"
|
||||
@@ -83,7 +94,19 @@ Does not include small "catering kitchens"
|
||||
which only include 20A provisions
|
||||
(microwaves, commercial refrigerators, etc.).
|
||||
|
||||
#### Area: Retail
|
||||
##### Area: Stairwells Building
|
||||
|
||||
* `Area` = "S - Stairwells Building"
|
||||
* `Phase` = "Building - Back of House (BOH)"
|
||||
|
||||
#### Tenant
|
||||
|
||||
Residents of leased units may accurately be called tenants,
|
||||
but the unqualified "tenant" almost always refers to _commercial_ tenants.
|
||||
|
||||
These spaces seem to be, by definition, [[construction-methods#Core and Shell|shell construction]].
|
||||
|
||||
##### Area: Retail
|
||||
|
||||
* `Area` = "XX - Level XX Retail Building"
|
||||
* `Phase` = "Retail"
|
||||
@@ -91,11 +114,14 @@ which only include 20A provisions
|
||||
Core and shell for mercantile occupancies.
|
||||
Does not include finished restaurants
|
||||
|
||||
#### Area: Office Space
|
||||
##### Area: Office Space
|
||||
|
||||
* `Area` = "XX - Level XX Retail Building"
|
||||
* `Phase` = "Office Space"
|
||||
|
||||
Core and shell for office occupancies.
|
||||
> [!quote] Joel Jansen to William Bonn 2025-12-05 (pp.)
|
||||
> PDI Accubid `Phase` "Office Space"
|
||||
> is normally used for core & shell retail office space
|
||||
|
||||
"coworking spaces"
|
||||
Interpreted as tenant coworking space, a la
|
||||
[Coworking & Office Space in St. Pete | Rising Tide](https://risingtidecowork.com/)
|
||||
|
||||
Reference in New Issue