id: 2025-08-15T14:15:41-0400
|
||||
title: 2025-08-15 14:15:41
|
||||
tags: []
|
||||
daily: "[[2025-08-15]]"
|
||||
---
|
||||
# 2025-08-15 14:15:41
|
||||
|
||||
Exact date of quote unknown.
|
||||
Assumed date is that of commit 85d30c0,
|
||||
the first commit the quote appeared
|
||||
in its previous location [[feeders-takeoff]],
|
||||
formerly "feeders.md".
|
||||
|
||||
> [!cite] [[joel-jansen]], in reference to Omni Hotels Raleigh (pp.)
|
||||
> It is acceptable to use typicals for identical feeders
|
||||
> (i.e. meter centers fed from bus plugs)
|
||||
> so long as the typical is in `Area` = "01 - Feeders/Risers ...".
|
||||
@@ -0,0 +1,20 @@
|
||||
---
|
||||
id: 2025-11-11T00:00:00-0500
|
||||
title: 2025-11-11 ??:??:??
|
||||
tags: []
|
||||
daily: "[[2025-11-11]]"
|
||||
---
|
||||
# 2025-11-11 ??:??:??
|
||||
|
||||
> [!quote] [[joel-jansen]] 2025-11-11, pp.
|
||||
>
|
||||
> For N5-15R/N5-20R receptacles serving fixed equipment such as:
|
||||
>
|
||||
> * refrigerators
|
||||
> * gas ranges
|
||||
> * microwaves
|
||||
> * clothes washers
|
||||
> * hood fans
|
||||
>
|
||||
> match the receptacle configuration shown on the plans
|
||||
> (i.e. simplex to simplex, duplex to duplex).
|
||||
@@ -11,6 +11,10 @@ daily: "[[2025-12-03]]"
|
||||
|
||||
## Excluding Vs. Ignoring Project Requirements
|
||||
|
||||
%%
|
||||
A criticism of an observed lack of [[transparency]] in [[construction-estimating]].
|
||||
%%
|
||||
|
||||
There is a distinct difference between _excluding_ and _ignoring_ requirements.
|
||||
|
||||
If, before award, you communicate to the customer
|
||||
|
||||
@@ -12,7 +12,9 @@ daily: "[[2025-12-10]]"
|
||||
|
||||
## ConEst Lighting Controls Meeting Notes
|
||||
|
||||
Related: [[lighting-controls-takeoff]]
|
||||
Meeting of all members of electrical [[conest|ConEst]]
|
||||
to discuss [[lighting-controls-takeoff]]
|
||||
lead by [[corwin-fluit]].
|
||||
|
||||
### Minutes
|
||||
|
||||
@@ -57,7 +59,8 @@ The lighting control problem is misunderstood.
|
||||
It's true that some technical training would be beneficial to ConEst estimators,
|
||||
but root of the problem has nothing to do with lighting control.
|
||||
|
||||
When I heard [[#^ex]], where lighting control went wrong
|
||||
When I heard [[#^ex|Corwin's example]],
|
||||
where lighting control went wrong
|
||||
and costed a job half a million in profit,
|
||||
what I took away was that we sold high-risk scope
|
||||
without knowing what was required _and without qualification_.
|
||||
|
||||
@@ -7,7 +7,7 @@ daily: "[[2025-12-12]]"
|
||||
---
|
||||
# 2025-12-12 09:38:52
|
||||
|
||||
A humorous exchange between a peer in estimating and myself:
|
||||
A humorous exchange between a peer in [[conest|ConEst]] and myself:
|
||||
|
||||
> **Peer:** "Your research will one day cure estimator's brain,
|
||||
> a disease sweeping across \[our\] floor"
|
||||
|
||||
@@ -9,7 +9,7 @@ daily: "[[2025-12-17]]"
|
||||
|
||||
%% [[statistical-modeling-for-construction-estimating]] %%
|
||||
|
||||
One aspect of estimating that I find most interesting,
|
||||
One aspect of [[construction-estimating]] that I find most interesting,
|
||||
but that is criminally understudied,
|
||||
is the effect of building dimensions
|
||||
(footprint shape, floor area, stories, height)
|
||||
|
||||
@@ -1,9 +0,0 @@
|
||||
---
|
||||
id: 2025-12-18T08:32:18-0500
|
||||
title: 2025-12-18 08:32:18
|
||||
tags:
|
||||
daily: "[[2025-12-18]]"
|
||||
---
|
||||
# 2025-12-18 08:32:18
|
||||
|
||||
[[uncertainty-in-construction-estimating]]
|
||||
@@ -9,7 +9,7 @@ daily: "[[2025-12-18]]"
|
||||
## Estimating Golf
|
||||
|
||||
What interests me most in [[construction-estimating]]
|
||||
is an idea you might call "estimating golf":
|
||||
is an idea you might call [[estimating-golf|"estimating golf"]]:
|
||||
the goal is to produce a satisfactory[^1] estimate,
|
||||
but the estimator can not view the project documents
|
||||
and must instead ask questions about the job
|
||||
|
||||
@@ -7,8 +7,11 @@ daily: "[[2026-01-04]]"
|
||||
---
|
||||
# 2026-01-04 ??:??:??
|
||||
|
||||
Horror is usually made more horrifying by the inclusion of one or more persons who do not find the situation horrifying.
|
||||
Horror is usually made more horrifying
|
||||
by the inclusion of one or more persons
|
||||
who do not find the situation horrifying.
|
||||
|
||||
One cannibal is bad, a society of cannibals is worse than the sum.
|
||||
One cannibal is bad,
|
||||
a society of cannibals is worse than the sum.
|
||||
|
||||
Book of the New Sun Severian
|
||||
[[the-book-of-the-new-sun|The Book of the New Sun]] Severian
|
||||
|
||||
@@ -9,6 +9,11 @@ daily: "[[2026-01-05]]"
|
||||
|
||||
## Bluebeam Scripting
|
||||
|
||||
%%
|
||||
Documentation on scripting
|
||||
for [[pdf]] editor Bluebeam Revu.
|
||||
%%
|
||||
|
||||
### Built-In
|
||||
|
||||
C:\Program Files\Bluebeam Software\Bluebeam Revu\21\Help\Bluebeam Script Reference.pdf
|
||||
|
||||
@@ -2,11 +2,11 @@
|
||||
id: 2026-01-07T06:41:00-0500
|
||||
title: 2026-01-07 06:41:??
|
||||
tags:
|
||||
- exclude-from-word-count
|
||||
daily: "[[2026-01-07]]"
|
||||
---
|
||||
# 2026-01-07 06:41:??
|
||||
|
||||
> [!quote] _The Shadow of the Torturer_, Chapter 17: "The Challenge"
|
||||
> No intellect is needed to see those figures who wait beyond the void of death---
|
||||
> every child is aware of them, blazing with glories dark or bright,
|
||||
> wrapped in authority older than the universe.
|
||||
@@ -21,4 +21,6 @@ daily: "[[2026-01-07]]"
|
||||
> (though we obey the orders of some prosaic person every day) our own masters,
|
||||
> when the truth is that our masters are sleeping.
|
||||
> One wakes within us and we are ridden like beasts,
|
||||
> though the rider is but some hitherto unguessed part of ourselves.
|
||||
> though the rider is but some hitherto unguessed part of ourselves.[^1]
|
||||
|
||||
[^1]: [[wolfe_1980_shadow#XVII - The Challenge]]
|
||||
|
||||
@@ -1,10 +1,16 @@
|
||||
---
|
||||
id: 2026-01-07T10:03:00-0500
|
||||
title: 2026-01-07 10:03:??
|
||||
tags:
|
||||
tags: []
|
||||
daily: "[[2026-01-07]]"
|
||||
---
|
||||
# 2026-01-07 10:03:??
|
||||
|
||||
At Ace, "residential" always meant single-family/duplex construction,
|
||||
%%
|
||||
Speculation about the meaning of [[construction]] terminology
|
||||
as understood by other contractors.
|
||||
%%
|
||||
|
||||
At [[ace-electric-inc|Ace]],
|
||||
"residential" always meant single-family/duplex construction,
|
||||
but I think now we were the outliers.
|
||||
|
||||
@@ -6,13 +6,14 @@ daily: "[[2026-01-09]]"
|
||||
---
|
||||
# 2026-01-09 16:28:??
|
||||
|
||||
### Occam's razor
|
||||
### Occam's Razor
|
||||
|
||||
> [!info] Also Known As
|
||||
> * the principle of parsimony
|
||||
> * the law of parsimony
|
||||
|
||||
recommends searching for explanations constructed with the smallest possible set of elements.
|
||||
Recommends searching for explanations constructed with the smallest possible set of elements.
|
||||
|
||||
Attributed to William of Ockham, 14th-century English philosopher and theologian.
|
||||
|
||||
> _Entia non sunt multiplicanda praeter necessitatem_
|
||||
@@ -21,5 +22,5 @@ Attributed to William of Ockham, 14th-century English philosopher and theologian
|
||||
> "Of two competing theories, the simpler explanation is to be preferred."
|
||||
|
||||
> [!quote] [[klugman-et-al_2019_loss-models#4.2 The Role of Parameters]]
|
||||
> The principle of parsimony states that the simplest model
|
||||
> that adequately reflects reality should be used.
|
||||
> The principle of parsimony states
|
||||
> that the simplest model that adequately reflects reality should be used.
|
||||
|
||||
@@ -7,11 +7,16 @@ daily: "[[2026-01-11]]"
|
||||
---
|
||||
# 2026-01-11 11:00:??
|
||||
|
||||
%%
|
||||
Comment on a flawed understanding of [[construction-estimating]],
|
||||
common even among estimators.
|
||||
%%
|
||||
|
||||
![[my-favorite-quotes#"It Takes an Engineer to Build a Bridge that Barely Stands"]]
|
||||
|
||||
The value that estimators provide for a contractor
|
||||
is in modeling project cost.
|
||||
If the goal were simply to present a number the cost will not exceed,
|
||||
is in _modeling project cost_.
|
||||
If the goal were simply to present a number that the cost will not exceed,
|
||||
than anyone could be an estimator.
|
||||
If the goal were only to present a reasonably accurate figure,
|
||||
with no other constraints,
|
||||
@@ -46,11 +51,13 @@ it is not cost-effective[^1] to allow it to take four.[^2]
|
||||
they may have reasonable basis to set sliding standards for estimate precision
|
||||
to be specifically determined at consideration of the opportunity for bid
|
||||
according to current climate (i.e. their transient risk appetite).
|
||||
|
||||
I believe my use of the absolute is still fair:
|
||||
No contractor is doing that, so they lack a competent measure of risk tolerance
|
||||
besides continuing to tolerate what they have historically.
|
||||
No contractor is doing that,
|
||||
so they lack a competent measure of risk tolerance
|
||||
besides continuing to tolerate what they have tolerated historically.
|
||||
|
||||
> [!important]
|
||||
> Objectionable as it is,
|
||||
> it is to be expected that estimators will use all time allowed them
|
||||
> when the standards for _acceptability_ are inadequately defined.
|
||||
> when the standards for **acceptability** are inadequately defined.
|
||||
|
||||
@@ -10,7 +10,7 @@ daily: "[[2026-01-12]]"
|
||||
### CH3 Executed Contract Revision WBS
|
||||
|
||||
[[executed-contract-revisions]]
|
||||
for CH3 South Nine and CH3 North Four (fka Crystal House III).
|
||||
for "CH3 South Nine and CH3 North Four (fka Crystal House III)".
|
||||
|
||||
For Executed Contract Revisions, Bid GP% must be maintained.
|
||||
In this case a negative variance was added to the buyout budget
|
||||
|
||||
@@ -8,10 +8,11 @@ daily: "[[2026-01-14]]"
|
||||
---
|
||||
# 2026-01-14 13:27:20
|
||||
|
||||
Follow-up to [[2026-01-13_11-28-14#Lighting Control]]
|
||||
Follow-up to [[2026-01-13_11-28-14#Lighting Control]].
|
||||
|
||||
Conversation between [[joel-jansen]] and [[christian-pereiro]]
|
||||
regarding [[lighting-controls]] for [[2100-crystal-drive]]:
|
||||
|
||||
> [!quote] Conversation between [[joel-jansen]] and [[christian-pereiro]] regarding lighting control for [[2100-crystal-drive]]:
|
||||
>
|
||||
> **Joel:** "It was sold as local."
|
||||
>
|
||||
> **Christian:** "Yeah, but you can't do that."
|
||||
|
||||
@@ -0,0 +1,14 @@
|
||||
---
|
||||
id: 2026-01-20T16:30:00-0500
|
||||
title: 2026-01-20 16:30:00
|
||||
tags: []
|
||||
daily: "[[2026-01-20]]"
|
||||
---
|
||||
# 2026-01-20 16:30:00
|
||||
|
||||
Quote previously located in [[feeders-takeoff]]
|
||||
on the subject of pool bonding takeoff:
|
||||
|
||||
> [!quote] [[joel-jansen]] 2026-01-20T16:30 (pp.)
|
||||
> [[josh-ford]] prefers it in electrical, but I'm not concerned.
|
||||
> So long as it's named "Pool Bonding" it's fine.
|
||||
@@ -10,6 +10,11 @@ daily: "[[2026-02-02]]"
|
||||
|
||||
## Sleeving Takeoff Breakdown Direction
|
||||
|
||||
> [!quote] [[joel-jansen]] 2026-02-02 12:10, while reviewing Howard University East Towers (pp.)
|
||||
> Match breakdowns of the relevant system,
|
||||
> i.e. don't change breakdowns after taking off
|
||||
> the assembly to be sleeved.
|
||||
|
||||
Updated [[sleeving-takeoff#Breakdowns]]
|
||||
per clarification with [[joel-jansen]].
|
||||
Previous direction below.
|
||||
|
||||
@@ -0,0 +1,14 @@
|
||||
---
|
||||
id: 2026-05-04T13:30:36-0400
|
||||
title: 2026-05-04 13:30:36
|
||||
tags: []
|
||||
daily: "[[2026-05-04]]"
|
||||
---
|
||||
# 2026-05-04 13:30:36
|
||||
|
||||
> [!quote] [[joel-jansen]] 2026-05-04 13:30 (pp.)
|
||||
> Use 0.5 labor hours for [[fixture-designations|fixtures]] in units.
|
||||
>
|
||||
> Using 1 hour doesn't make a functional difference
|
||||
> because of the [[pdi-labor-plan|labor plan]] Labor Factor adjustment,
|
||||
> but those adjustments may look very steep (~30%) with 1 hour each.
|
||||
@@ -0,0 +1,22 @@
|
||||
---
|
||||
id: 2026-05-04T14:57:49-0400
|
||||
title: 2026-05-04 14:57:49
|
||||
tags: []
|
||||
daily: "[[2026-05-04]]"
|
||||
---
|
||||
# 2026-05-04 14:57:49
|
||||
|
||||
Direction from [[joel-jansen|Joel]]
|
||||
|
||||
## Telecom Homeruns
|
||||
|
||||
[[telecom-takeoff#Corridor Conduit (IDF to Unit MSDE)]]
|
||||
|
||||
It is acceptable to use a weighted average length
|
||||
in a "Typical - All Units"
|
||||
in lieu of individual takeoffs per floor.
|
||||
|
||||