vault backup: 2025-09-04 17:03:46

This commit is contained in:
2025-09-04 17:03:46 -04:00
parent 9ba8223304
commit e5589c385c
6 changed files with 66 additions and 40 deletions
+4 -3
View File
@@ -114,17 +114,18 @@ Use assembly `Common Assemblies`/`Device Homeruns in Slab/Deck`
### Tape Lighting
Also called "cove" or "strip",
Also called "cove" or "strip" lighting,
however those terms are less specific
and potentially confusing.
Use item `FIXTURE LABOR 1/2HR`
and change `Fct 1` to match the calculated labor.
and change `Fct 1` to match the calculated labor
(1 hour per 12 feet).
> [!note]
> Tape lighting length is limited by the "max power length" of the model
> (usually measured in millimeters).
> Max power length is usually 5000 to 15000 mm (about 16 to 49 ft)
> Max power length is usually 5000-15000mm (~16-49ft)
> depending on luminous output and voltage.
Separate these fixtures by labor, not length