vault backup: 2025-11-06 17:21:38
This commit is contained in:
+40
-29
@@ -33,26 +33,26 @@ Use empty designations to separate phases.
|
||||
>
|
||||
> ```
|
||||
> *** Hotel Units ***
|
||||
> HU - Surface (MC) LV 20ft
|
||||
> HU - Surface - 1.5hrs (MC) LV 20ft
|
||||
> HU - Surface: Pendant - 2.0hrs (MC) LV 20ft
|
||||
> HU - Surface: J-Box For Future Fixture (MC) LV 20ft
|
||||
> HU - Recessed (MC) LV 20ft
|
||||
> HU - Surface = 1.0hrs - #12 MC+LV 20ft
|
||||
> HU - Surface = 1.5hrs - #12 MC+LV 20ft
|
||||
> HU - Surface: Pendant = 2.0hrs - #12 MC+LV 20ft
|
||||
> HU - Surface: J-Box For Future Fixture = 1.0hrs - #12 MC+LV 20ft
|
||||
> HU - Recessed = 1.0hrs - #12 MC+LV 20ft
|
||||
> *** Condo Units ***
|
||||
> CU - Surface: Tape - 1.0hrs (MC) LV 25ft
|
||||
> CU - Surface: Wall (MC) LV 25ft
|
||||
> CU - Surface: Tape = 1.0hrs - #12 MC+LV 25ft
|
||||
> CU - Surface: Wall = 1.0hrs - #12 MC+LV 25ft
|
||||
> ```
|
||||
|
||||
## Fixture Labor
|
||||
|
||||
| Fixture Type | Labor |
|
||||
| ------------ | ------------ |
|
||||
| Paddle Fan | 1.5 hrs/ea |
|
||||
| Pendant | 1-4 hrs/ea |
|
||||
| Strip/Cove | 0.083 hrs/ft |
|
||||
| Site Poles | 1.5 hrs/ea |
|
||||
| Festoon | 2 hrs/ea |
|
||||
| All Others | 1 hrs/ea |
|
||||
| Fixture Type | Labor |
|
||||
|:------------ | -----------:|
|
||||
| Paddle Fan | 1.5 hr/ea. |
|
||||
| Pendant | 1-4 hr/ea. |
|
||||
| Strip/Cove | 0.5 hr/6ft |
|
||||
| Site Poles | 1.5 hr/ea. |
|
||||
| Festoon | 2.0 hr/ea. |
|
||||
| All Others | 1.0 hr/ea. |
|
||||
|
||||
## Fixture Branch Length
|
||||
|
||||
@@ -67,16 +67,22 @@ Use empty designations to separate phases.
|
||||
| Exterior Amenity | 50ft |
|
||||
| Units | 20ft |
|
||||
| Undercabinet Fixtures | 10ft |
|
||||
| Stairwells | ? |
|
||||
| Kitchen | ? |
|
||||
|
||||
Reduce as appropriate.
|
||||
|
||||
## Fixture Branch Wire size
|
||||
|
||||
| Case | Wire Size |
|
||||
| -------------- | --------- |
|
||||
| Site/Courtyard | #10[^1] |
|
||||
| Site/Courtyard | #10 |
|
||||
| Garage | #10 |
|
||||
| NM Cable | #14[^2] |
|
||||
| NM Cable | #14[^1] |
|
||||
| All Others | #12 |
|
||||
|
||||
[^1]: Minimum #12 in kitchens and bathrooms.
|
||||
|
||||
## Garage
|
||||
|
||||
### Fixtures
|
||||
@@ -99,7 +105,7 @@ If PVC is required, use following assemblies:
|
||||
|
||||
Use 1 Homerun for every 3 circuits in Garage
|
||||
|
||||
Use assembly `Common Assemblies`/`Device Homeruns in Slab/Deck`
|
||||
Use assembly `COMMON ASSEMBLIES`/`Device Homeruns in Slab/Deck`
|
||||
|
||||
## Surface Mount
|
||||
|
||||
@@ -140,15 +146,20 @@ and change `Fct 1` to match the calculated labor
|
||||
Separate these fixtures by labor, not length
|
||||
|
||||
```
|
||||
A - Surface: Tape - 0.5hr (01-06ft) - MC #12 40ft
|
||||
A - Surface: Tape - 1.0hr (07-12ft) - MC #12 40ft
|
||||
A - Surface: Tape - 1.5hr (13-18ft) - MC #12 40ft
|
||||
A - Surface: Tape - 2.0hr (19-24ft) - MC #12 40ft
|
||||
A - Surface: Tape - 2.5hr (25-30ft) - MC #12 40ft
|
||||
A - Surface: Tape - 3.0hr (31-36ft) - MC #12 40ft
|
||||
A - Surface: Tape - 3.5hr (37-42ft) - MC #12 40ft
|
||||
A - Surface: Tape - 4.0hr (43-48ft) - MC #12 40ft
|
||||
A - Surface: Tape - 4.5hr (49-54ft) - MC #12 40ft
|
||||
*** Back of House ***
|
||||
B - Surface: Tape = 0.5hr (01-06ft) - MC #12 40ft
|
||||
B - Surface: Tape = 1.0hr (07-12ft) - MC #12 40ft
|
||||
_
|
||||
*** Interior Amenity ***
|
||||
IA - Surface: Tape = 0.5hr (01-06ft) - MC+LV #12 40ft
|
||||
IA - Surface: Tape = 1.0hr (07-12ft) - MC+LV #12 40ft
|
||||
IA - Surface: Tape = 1.5hr (13-18ft) - MC+LV #12 40ft
|
||||
IA - Surface: Tape = 2.0hr (19-24ft) - MC+LV #12 40ft
|
||||
IA - Surface: Tape = 2.5hr (25-30ft) - MC+LV #12 40ft
|
||||
IA - Surface: Tape = 3.0hr (31-36ft) - MC+LV #12 40ft
|
||||
IA - Surface: Tape = 3.5hr (37-42ft) - MC+LV #12 40ft
|
||||
IA - Surface: Tape = 4.0hr (43-48ft) - MC+LV #12 40ft
|
||||
IA - Surface: Tape = 4.5hr (49-54ft) - MC+LV #12 40ft
|
||||
```
|
||||
|
||||
## Recessed
|
||||
@@ -247,13 +258,13 @@ Add subassemblies for stub-outs, pole, base, and grounding as appropriate.
|
||||
| Fixture Type | Path (`FIXTURE ACCESSORIES`/`COURTYARDS & LANDSCAPE`/...) |
|
||||
| ------------------------------------ | ------------------------------------------------------------------ |
|
||||
| Step Light | .../`STEP FIX, 3/4" CONDUIT - PVC40 - ...` |
|
||||
| Bollard | .../`BOLLARD, 3/4" CONDUIT - PVC40 - ...`[^1] |
|
||||
| Bollard | .../`BOLLARD, 3/4" CONDUIT - PVC40 - ...`[^2] |
|
||||
| Up-light | .../`PERMA POST, 3/4" CONDUIT - PVC40 - ...` |
|
||||
| In-grade up-light | .../`3/4" CONDUIT - PVC40, IMC Elbow, ...` |
|
||||
| Fixtures built into cabanas/pergolas | .../`ALUM BOX W/ FLEX FIX, 3/4" CONDUIT - PVC40 - ...` |
|
||||
| Handrail light | .../`ALUM BOX W/ FLEX FIX, 3/4" CONDUIT - PVC40, IMC ELBOW - ...` |
|
||||
|
||||
[^1]: If we don't own concrete, delete Pre-cast bollard base from assembly
|
||||
[^2]: If we don't own concrete, delete Pre-cast bollard base from assembly
|
||||
|
||||
## FAA Lighting
|
||||
|
||||
|
||||
Reference in New Issue
Block a user