--- id: 2026-05-14T08:19:37-0400 title: 2026-05-14 08:19:37 tags: - occupational daily: "[[2026-05-14]]" --- # 2026-05-14 08:19:37 ## 303 Mariposa Residence Pre-takeoff Confirmation Email Review Consultation with [[josh-ford|Josh]] regarding [[conest-pre-takeoff-confirmation]] for [[303-mariposa-residence]]. The project being a single family home, primary estimator [[jared-defanti]] requested Josh's aid with precise wording and takeoff assumptions. ### Questions > [!quote] Proposal 2026-05-06 > _Telecom, Data & Cable TV _ > > 49\. Back boxes and stub ups "As required" Josh confirmed we are to exclude backboxes and stub-ups from takeoff. ### Other Direction #### Metal Boxes Highlight 12 AWG minimum, metal boxes; add note "please confirm". #### PVC Conduit Confirmed no PVC except secondaries. Secondaries PVC40 with PVC80 elbow and stub-up. #### Project Drawing/Detail Callouts Delete section [[conest-pre-takeoff-email-template#Project Drawing/Detail Callouts]] since empty. #### Fire Alarm Use `TERMINAL CABINET` not `HEAD END`. Did not specifically discuss with Josh, but assuming free-air assemblies for devices #### Lighting Control Confirmed 0-10V/Line voltage dimming per schedule. Use "Low voltage" (rough-in only) assemblies Note "rough-in only" in email. > Josh pointed out dimming receptacles. #### Low Voltage Add new line: "Shade Control: System is alternate, do we own rough-in?". #### Other Josh noted that [[conest#ConEst Senior Estimator|seniors]] appreciate the new [[conest-pre-takeoff-confirmation]] process because they feel more familiar with the job when in [[conest-senior-review]].