--- id: aliases: [] tags: - authorship/original - destiny/permanent - occupational/takeoff/fire-alarm - status/draft - type/guide title: Fire Alarm Takeoff --- # Fire Alarm Takeoff > [!important] > Complete [[emergency-systems-research]] before beginning takeoff. > [!info] > See [[fire-alarm]] for information about fire alarm systems. ## Assembly Selection Free Air < PVC in Slab < EMT _High Rise (Steel & slab):_ Free air in Units, use conduit elsewhere. _Mid Rise, High Density (Wood frame):_ Free air, conduit only where required. ## Backbone Put all backbone takeoff in the `Area` of the Fire Command Center. Include [[sleeving-takeoff]] as necessary. ### Fire Command Center `COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`HEAD END EQUIP`/`... HEAD END` ### Generator Room `Area` = Same as FACR `COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`GENERATOR ROOM ...` ### Fire Pump Room `Area` = Same as FACR `COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`FIRE PUMP ROOM ...` ### Elevator Control Rooms > Also "Elevator Machine Room" For each Elevator Control Room (ECR): `COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`ELEV CONTROL ROOM ...` * **Count** = 1 `COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`FACR TO ELEV CONTROL RM ...` * **Length** = Length measured from the most distant points of the FACR and ECR. * Input adder length to reach the level of the ECR (Minimum 15ft). ### Elevator Shafts `Area` = Same as FACR For each elevator shaft: `COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`ELEV SHAFT ...` * **Count** = 1 `COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`FACR TO ELEV SHAFT ...` * **Length** = Length measured from the most distant points of the FACR and elevator shaft. * Input adder length to reach the level of the shaft (Minimum 15ft). > [!important] Counting Elevator Shafts > Adjacent elevators may be in the same or parallel shafts. > Count the shafts accordingly: > > ``` > | | | > | || +--------+ +--------+ || | || +--------+ || +--------+ || | > | || | Elev 1 | | Elev 2 | || | || | Elev 1 | || | Elev 2 | || | > | || +--------+ +--------+ || | || +--------+ || +--------+ || | > | ||=======================|| | ||============||============|| | > | 1 shaft | 2 shafts | > ``` ### FACR to Stairwells > [!info] > This is for the Flow/Tamper modules in the stairwells For each stairwell: `COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`FACR TO STAIRWELLS 1" CONDUIT ...` * **Length** = Length measured from the most distant points of the FACR and stairwell. * Input adder length to reach the level of the stairwell (Minimum 15ft). ## Terminal Cabinets `COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`TERMINAL CABINET`/`ACE D ACCESSORY CABINET ENCLOSURE ...` * _Garden Style, High Density:_ (2) 1"C * _High Rise:_ (2) 2"C Horizontal: > * `Area` = Same as FACR > * **Length** = Length measured from FACR to all electrical rooms Vertical: > * `Area` = "Typical - Building All Levels" > * **Length** = 10ft ## Annunciator Panels > [!info] Also Known As > * Fire Alarm Annunciator (FAA) > * Fire Alarm Annunciator Panel (FAAP) > `COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`ANNUNCIATORS`/`REMOTE SERIAL ANNUNCIATOR ...` > * **Length** = Length measured from the FACR to FAA or Lobby ## Central Monitoring Loop > [!important] > Garden Style only. > Fire Alarm Control Panels from each building will send a signal to a central location. > > In case of an emergency, > the fire department will go to the central fire alarm station > and find out what the issue is. ## Devices ### Smoke Detectors _Design Build:_ Count every stairwell at every level. ### Pull Stations _Design Build:_ Count every stairwell at every level and every exterior exit. ### Flow/Tamper Switches No free-air. If wood frame, take off as EMT. _Design Build:_ Count every stairwell at every level. ### Magnetic Door Holders `COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`INDICATING DEVICES WITH WIRE - ...`/`MAGNETIC DOOR HOLDER - ...` _Design Build:_ Count 2 for every set of double doors. (Typical of elevator lobbies and corridors) ### Speaker Strobes _Design Build:_ * Count every 75 ft, * measure with circles on Bluebeam * or divide relevant SF area by 4415 * $\pi(\frac{75}{2})^2 \approx 4415$ * every elevator lobby, * and every BOH room on the first floor and garage levels. _Design Build (alt):_ * 15ft from end of corridor, * then every 50ft ## Firefighter Phone System * firefighter phone jacks * fire warden station * fire phone cabinet Communicates directly with FACR. Not related to responder radio. `COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`COMMUNICATION DEVICES ...`/`...` ## Fire Smoke Dampers (FSD's) For each damper, take off both `System` = "FA - Fire Alarm" `COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`INITIATING DEVICES ...`/`ADDRESSABLE OUTPUT RELAY MODULE ...` and `System` = "EL - Electrical" `COMMON ASSEMBLIES`/`MISC ASSEMBLIES`/`FSD ...`