--- id: aliases: [] tags: - destiny/permanent - occupational/takeoff/fire-alarm - status/draft - type/guide - authorship/original title: Fire Alarm --- # Fire Alarm > [!info] > See [[fire-alarm]] for information about fire alarm systems. ## Backbone Put all backbone takeoff in the `Area` of the Fire Command Center. Include [[sleeving-takeoff]] as necessary. ### Fire Command Center `COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`HEAD END EQUIP`/`... HEAD END` ### Generator Room `COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`GENERATOR ROOM ...` ### Fire Pump Room `COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`FIRE PUMP ROOM ...` ### FACR to Elevator Shafts `COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`ELEV SHAFT ...` `COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`FACR TO ELEV SHAFT ...` Measure Length from the most distant points of the FACR and each shaft. Input adder length to reach the bottom of the pit (Minimum 15ft). > [!important] Counting Elevator Shafts > Adjacent elevators may be in the same or parallel shafts. > Count the shafts accordingly: > > ``` > | | | > | || +--------+ +--------+ || | || +--------+ || +--------+ || | > | || | Elev 1 | | Elev 2 | || | || | Elev 1 | || | Elev 2 | || | > | || +--------+ +--------+ || | || +--------+ || +--------+ || | > | ||=======================|| | ||============||============|| | > | 1 shaft | 2 shafts | > ``` ### FACR to Elevator Control Rooms `COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`ELEV CONTROL ROOM ...` `COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`FACR TO ELEV CONTROL RM ...` * Measure the Horizontal and Vertical Distance from the FACR to the ECR. * Use Typicals for the vertical riser. (10ft per floor) ### FACR to Stairwells > [!info] > This is for the Flow/Tamper modules in the stairwells `COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`FACR TO STAIRWELLS ...` * Measure from the furthest end of FACR to the furthest end of the stairwell to find length ### Terminal Cabinets `COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`TERMINAL CABINET`/`ACE D ACCESSORY CABINET ENCLOSURE (2) 2" ...` * _Garden Style, High Density:_ (2) 1"C * _High Rise:_ (2) 2"C Horizontal: * Measure from the Fire Command room to all electrical rooms Vertical: * Use 10ft Riser in Typical ### Annunciator Panels > [!info] Also Known As > * Fire Alarm Annunciator (FAA) > * Fire Alarm Annunciator Panel (FAAP) `COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`ANNUNCIATORS`/`REMOTE SERIAL ANNUNCIATOR ...` * Measure from the Fire Command Room to FAA or Lobby ## Devices ### Smoke Detectors _Design Build:_ Count every stairwell at every level. ### Pull Stations _Design Build:_ Count every stairwell at every level and every exterior exit. ### Flow/Tamper Switches No free-air. If wood frame, take off as EMT. _Design Build:_ Count every stairwell at every level. ### Magnetic Door Holders `COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`INDICATING DEVICES WITH WIRE - ...`/`MAGNETIC DOOR HOLDER - ...` _Design Build:_ Count every set of double doors. (Typical of elevator lobbies and corridors) ### Speaker Strobes _Design Build:_ * Count every 75 ft, * measure with circles on Bluebeam * or divide relevant SF area by 4415 * $\pi(\frac{75}{2})^2 \approx 4415$ * every elevator lobby, * and every BOH room on the first floor and garage levels. ## Firefighter Phone System * firefighter phone jacks * fire warden station * fire phone cabinet Communicates directly with FACR. Not related to responder radio. `COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`COMMUNICATION DEVICES ...`/`...` ## Fire Smoke Dampers (FSD's) For each damper, take off both `System` = "FA - Fire Alarm" `COMMON ASSEMBLIES`/`MISC ASSEMBLIES`/`FSD ...` and "EL - Electrical" `COMMON ASSEMBLIES`/`MECHANICAL CONNECTIONS (UP TO 100A)`/.../...