--- id: 2026-02-11T12:12:16-05:00 aliases: [] title: 2026-02-11 12:12:16 tags: - authorship/original - destiny/permanent - status/draft - type/periodic/timestamped daily: "[[2026-02-11]]" dg-publish: true monthly: "[[2026-02]]" quarterly: "[[2026-Q1]]" weekly: "[[2026-W07]]" yearly: "[[2026]]" --- # 2026-02-11 12:12:16 Hello Team, Below is a comprehensive list of means & methods for **1990 K Street**. Please confirm you have received this email and respond with any questions or comments. * **Takeoff Request Stage:** Full Takeoff %% Stage 1, Stage 1 + Units, Full takeoff %% * **Delivery Method:** Plans & Specs %% Plans & Specs, Design Build, Design Assist, P&S with Approved VE %% * **Document Stage:** Permit %% DD, CD, Permit, GMP, Bid, Awarded %% * **Drawings Date:** 2025-12-05 * **Project Manual Date:** 2025-12-05 * **Proposal Date:** 2026-01-22 ### Project Specification Callouts %% Put page of Drawing or PM after answer %% * **Conduit:** * EMT Fittings: Set-screw _---Spec 260533.13 (p. 1423)_ %% GRC, coupling specs, etc. %% * **Wire:** * Material: Aluminum 100A and larger _---E021 "ALUMINUM FEEDER SCHEDULE" Note 1(b)_ * Acceptable Manufacturers: _---Spec 260519 (p. 1384)_ * Alpha Wire; Brand of Belden, Inc. * Belden Inc. * Cerro Wire LLC * Encore Wire Corporation * General Cable; Prysmian Group North America * Okonite Company * Service Wire Co. * Southwire Company, LLC * WESCO * **MC Cable:** * Application: Concealed feeders and branch circuits _---Spec 260519 (p. 1389)_ %% Branch homeruns only; Not permitted %% * Acceptable Manufacturers: _---Spec 260519 (p. 1385-1386)_ * AFC Cable Systems; Atkore International * Alpha Wire; Brand of Belden, Inc. * Belden Inc. * Cerro Wire LLC * Encore Wire Corporation * General Cable; Prysmian Group North America * Okonite Company * Southwire Company, LLC * WESCO * ==Conductors: Copper _---Spec 260519 (p. 1386)_== * ==Armor: Steel _---Spec 260519 (p. 1386)_== * ==Jacket: PVC _---Spec 260519 (p. 1386)_== * **Steel Box Depth:** * Telecom: 2-1/8" _---Spec 270500 (p. 1673)_ * Security: 2-1/8" _---Spec 280500 (p. 1753)_ * Other Applications: Not specified %% 1-1/2", 2-1/8" %% * **Floor Boxes:** Sheet metal with brass or aluminum covers _---Spec 262719 (p. 1541)_ * **Wiring Devices:** * Units: * Current rating: Unspecified. Assuming 15A for takeoff. * Standard/Decora: Unspecified. Assuming Toggle/Duplex for takeoff. %% 15A Decora %% * BOH/Common Areas: * Current rating: Unspecified. Assuming 20A for takeoff. * Standard/Decora: Unspecified. Assuming Toggle/Duplex for takeoff. %% 20A Toggle/Duplex %% * **Switchboards:** * Acceptable Manufacturers: _---Spec 262413 (p. 1502)_ * ABB, Electrification Business * Eaton * Siemens Industry, Inc., Energy Management Division * Square D; Schneider Electric USA * General Electric * Bus Material: Aluminum _---Spec 262413 (p. 1503)_ * Interrupting Current Rating: Not specified. * **Distribution Panelboards:** * Acceptable Manufacturers: _---Spec 262413 (p. 1514-1515)_ * Eaton * Bus Material: Aluminum _---Spec 262413 (p. 1513)_ * Breaker Types: Bolt-on _---Spec 262413 (p. 1515)_ %% Snap-on, bolt on %% * Interrupting Current Rating: Not specified. * **Load Centers:** * Acceptable Manufacturers: _---Spec 262413 (p. 1514-1515)_ * ABB, Electrification Business * Eaton * Siemens Industry, Inc., Energy Management Division * Square D; Schneider Electric USA * Bus Material: Aluminum _---Spec 262413 (p. 1513)_ * Breaker Types: Plug-in _---Spec 262413 (p. 1515)_ %% Snap-on, bolt on %% * Interrupting Current Rating: Not specified. * ==Covers shall be factory-applied white paint.== _---Dwg. E401-E405 "ELECTRICAL DRAWING NOTES" (P)_ * **Transformers:** * Winding Material: Aluminum _---Spec 262213 (p. 1495)_ * K-Rating: Not specified. %% Windings AL or CU, K-rating %% * **Generator:** (1) 600kW Diesel * Enclosure Specs: Level 2 Sound Attenuating Weatherproof Enclosure _---Dwg. E014_ * Remote Tank: None shown or specified. * Tank Size: 24hrs at 100% load _---Spec 263213.13 (p. 1604)_ * Load Banks: Internal, 50% load _---Dwg. E014, Spec 263213.13 (p. 1608)_ * Acceptable Manufacturers: _---Spec 263213.13 (p. 1600)_ * Caterpillar, Inc.; Electric Power Division * Cummins Power Generation * Generac * Hipower Systems * Kohler Power Systems * Rolls-Royce Solutions America Inc ### Project Drawing/Detail Callouts Dwg. IDS-01A "OUTLET SPECIFICATIONS": Screwless Cover Dwg. IDS-01A "SWITCHING SPECIFICATIONS": Legrand Tru-Universal Rocker/Dimmers (Is this for Amenity/Common Areas?) ### PDI System Execution Plan * **Primaries:** Conduit and wiring excluded. _---Proposal 2026-01-22, Ex. B, Exclusions, Line 27_ %% Installation only, (9) 6" PVC %% * **Secondaries:** * Schedule 40 PVC UG; _---Proposal 2026-01-22, Ex. B, Inclusions Line 54-55_ * wiring excluded. _---Proposal 2026-01-22, Ex. B, Exclusions, Line 28_ %% PVC UG, GRC Stub-ups, AL %% * **Feeders:** PVC UG, EMT OH; AL 100A and larger; 2% voltage drop. %% PVC UG, EMT OH, AL over 100A, 2% VD %% %% Emergency Feeds MI Cable %% * **Unit Subfeeds:** MC OH; size per E025-E028 meter bank schedules; 3% voltage drop. %% MC OH AL, VD per Chart on E5.01 %% * **Units:** * DW/Disposal - Separate Circuit * Range - \#6/3 * Kitchen Backsplash - Decora (Non-Combo Small Appliance Breakers) * 120V Smokes * EWH - \#8/2 * VRF HVAC * 20A Toggle Switches * 15A Duplex Receptacles %% 15A Decora, Disposals, T-stat, Floor Boxes, Shade Control, Doorbells, Dimmer Switches, etc. %% * **Telecom:** * 30" MSDE; _---T0.32/1 Note 3: "PRIMEX SOHOPRO P3000ND"_ * (1) 1" innerduct to IDF. _---Proposal 2026-01-22, Ex. B, General Requirements, Line 114_ %% 42" MSDE, No Cable Homeruns, (1) 1" Back to IDF, CAT6 with Stub-ups %% * **EV Chargers:** (2) dual circuit chargers with conduit, wire, data rough-in, and equipment. %% (42) Conduit only, (56) Conduit & Wire, (20) Conduit, Wire & Equipment %% * **Fire Alarm:** Devices PVC in-slab, Risers EMT. %% Free-air where allowed by code. EMT Risers. %% * **DAS:** System per PDI DAS Design. %% Conduit only, Per PDI DAS Design %% * **Low Voltage:** Free-air where allowed by code. %% Free-air where allowed by code. Stub-ups to accessible ceilings. %% ### Lighting Control * **Basis of Takeoff:** Design per Plans and Specs _---Christian Pereiro 2026-02-11_ %% Code Minimum per Energy Code Assigned, P&S, PDI Design %% * **Area:** _---Dwg. E021 "AUTOMATED LIGHTING CONTROL - SEQUENCES OF OPERATIONS"_ * BOH: Line Voltage Control, no dimming * Corridor: Digital Standalone Control, 0-10V dimming * Amenity: Digital Standalone Control, 0-10V dimming * Offices: Digital Standalone Control, 0-10V dimming, controlled receptacles as shown * Site/Landscape: Line Voltage Control, no dimming * Garage: Digital Standalone Control, 0-10V dimming %% Assign Method to Areas: Line Voltage, Low-Voltage Stand Alone or Centralized System %% Takeoff will utilize assemblies including conduit rough-in, Cat5e cable, and device labor. ### Tasks/Quotes Needed for WBS %% Delete any completed %% %% * Electrical Constructability Review %% %% * Electrical VDC %% * Coordination Study %% * DAS Public Safety Raceway Design %% Thank you,