Files
zmVault/units-takeoff.md
T

4.4 KiB

id, aliases, title, tags, dg-publish
id aliases title tags dg-publish
Unit Takeoff
authorship/original
destiny/permanent
occupational/takeoff
status/draft
type/guide
true

Unit Takeoff

[!info] See multi-family-dwellings.

pdi-building-types

Prerequisites

Important

Complete pre-takeoff-research, including wiring-method-selection and wiring-device-research, before beginning takeoff.

  1. pdi-conest-project-setup#Create Unit Matrix
  2. accubid-setup#Create Unit Typicals

Takeoff

[!tip] Preparing for Unit Takeoff Units generally have very little variation. It is usually best to copy-paste takeoffs rather than re-build them for each unit.

  1. Kitchen and Bath
  2. General assemblies
  3. Low Voltage
  4. Lighting Fixtures
  5. Lighting Control

Tip

It may be more efficient and neat to not copy switches, instead keeping the switch assembly list open and creating them new for each unit, since the types required can vary greatly between units.

Tip

Consider using a "Typical - All Units" for scope identical between all unit types.

  • WAP Outlets
  • MSDE's

Load Centers

  • System = "EL - Electrical"
Rating Assembly
<= 100A DIST PANELS & UNIT LOAD CENTERS/UNIT LOAD CENTERS - .../... UNIT LOAD CENTER
> 100A DIST PANELS & UNIT LOAD CENTERS/UNIT LOAD CENTERS - .../... BREAKER PNL

Include terminations per switchgear-takeoff.

Fixtures

fixtures-takeoff

Shade Control

VTAC Units

Used in lieu of individual split systems.

Dedicated Circuit Receptacles

[!quote] joel-jansen 2025-11-11, pp.

For N5-15R/N5-20R receptacles serving fixed equipment such as:

  • refrigerators
  • gas ranges
  • microwaves
  • clothes washers
  • hood fans

match the receptacle configuration shown on the plans (i.e. simplex to simplex, duplex to duplex).

Air Sealing

  • LEED Silver
  • Mid-Atlantic jobs
  • "Draft Proof Box"

ITEM DATABASE/BOXES & CABINETS/BOXES - VAPOR/...

COMMON ASSEMBLIES/UNITS - MC CABLE ASSEMBLIES/GENERAL ASSEMBLIES - METAL STUD/UNIT MISC ITEMS - MC - ADJUST ACCORDINGLY

Dishwasher/Disposal Receptacles

[!quote] joel-jansen 2026-01-12 in Reference to woodbrook (pp.)1 Even when drawings show 2 separate duplex receptacles, use DW & DISPOSAL DUAL CIR - ..., which includes only one receptacle.

Islands

Use (1) SLAB / DECK receptacle for every 2 circuits in the island.

COMMON ASSEMBLIES/UNITS - MC CABLE ASSEMBLIES/... RECEPTACLE TAMPER RESISTANT .../... (METAL STUD) - 20' 3/4" PVC, ENT, 3#12 THHN

Use standard MC assemblies for remaining devices.

Bidet Toilets, Whirlpool Baths, etc.

COMMON ASSEMBLIES/MECHANICAL CONNECTIONS (UP TO 100A)/PVC - LT NM FLEX (CARFLEX)/20A 1PH MECH CONN (100') 3/4" PVC 3#12 - CARFLEX

"High-Lows"

Empty in-wall pass through from credenza location to behind television location.

COMMON ASSEMBLIES/TELECOM SYSTEMS/UNIT DATA - TELECOM/HIGH-LOW - TV SCOOP 1 1/2" ENT - NO CABLE

Eaton 35M2W|250x250

Eaton 35M2W

Doorbells

???

HANDICAP DB W/SINGLE HORN/STROBE - 12/2c MC CABLE

Telecom Homeruns

Residential

Included in MSDE.

Key

COMMON ASSEMBLIES/TELECOM SYSTEMS/BOH AMENITY ASSEMBLIES/...

Adjust cable length as needed.

Fire Alarm Devices

Residential

  • System = "EL - Electrical"
Smoke Detectors & CO Detectors

For smoke detectors and CO detectors where 120V (most common):

COMMON ASSEMBLIES/UNITS - MC CABLE ASSEMBLIES/GENERAL ASSEMBLIES - METAL STUD/UNIT SMOKE DETECTOR W/ CO DETECTOR ...

For ADA units:

COMMON ASSEMBLIES/UNITS - MC CABLE ASSEMBLIES/GENERAL ASSEMBLIES - METAL STUD/UNIT SMOKE DETECTOR / VISUAL SIGNAL ...

Additional Signaling Devices
  • System = "FA - Fire Alarm"

COMMON ASSEMBLIES/FIRE ALARM & DAS SYSTEMS/INDICATING DEVICES WITH WIRE - FREE AIR/INDOOR HORN STROBE - FREE AIR

Key

  • System = "FA - Fire Alarm"

COMMON ASSEMBLIES/FIRE ALARM & DAS SYSTEMS/... DEVICES WITH WIRE - FREE AIR

fire-alarm-takeoff


  1. 2026-01-12#Unit Dishwasher/Disposal ↩︎