Files
zmVault/units-takeoff.md
T

3.0 KiB

id, aliases, tags, title
id aliases tags title
authorship/original
destiny/permanent
occupational/takeoff/units
status/draft
type/guide
Unit Takeoff

Unit Takeoff

Important

Complete pre-takeoff-research, including wiring-method-selection and wiring-device-research, before beginning takeoff.

[!info] See multi-family-dwellings.

Takeoff

[!tip] Preparing for Unit Takeoff Units generally have very little variation. It is usually best to copy-paste takeoffs rather than re-build them for each unit.

  1. Kitchen and Bath
  2. General assemblies
  3. Low Voltage
  4. Lighting Fixtures
  5. Lighting Control

Tip

It may be more efficient and neat to not copy switches, instead keeping the switch assembly list open and creating them new for each unit, since the types required can vary greatly between units.

Load Centers

Rating Assembly
<= 100A DIST PANELS & UNIT LOAD CENTERS/UNIT LOAD CENTERS - .../... UNIT LOAD CENTER
> 100A DIST PANELS & UNIT LOAD CENTERS/UNIT LOAD CENTERS - .../... BREAKER PNL

Include terminations per switchgear.

Shade Control

VTAC Units

Used in lieu of individual split systems.

Dedicated Circuit Receptacles

For N5-15R/N5-20R receptacles serving fixed equipment such as:

  • refrigerators
  • gas ranges
  • microwaves
  • clothes washers
  • hood fans

use single receptacle assemblies, even where shown as duplex.

COMMON ASSEMBLIES/UNITS - MC CABLE ASSEMBLIES/KITCHEN & BATH ASSEMBLIES - METAL STUD/SGL REC ...

Air Sealing

  • LEED Silver
  • Mid-Atlantic jobs
  • "Draft Proof Box"

ITEM DATABASE/BOXES & CABINETS/BOXES - VAPOR/...

COMMON ASSEMBLIES/UNITS - MC CABLE ASSEMBLIES/GENERAL ASSEMBLIES - METAL STUD/UNIT MISC ITEMS - MC - ADJUST ACCORDINGLY

Islands

Use 1 "SLAB / DECK" receptacle for every 2 circuits in the island.

COMMON ASSEMBLIES/UNITS - MC CABLE ASSEMBLIES/... RECEPTACLE TAMPER RESISTANT .../... (METAL STUD) - 20' 3/4" PVC, ENT, 3#12 THHN

Use standard MC assemblies for remaining devices.

Bidet Toilets, Whirlpool Baths, etc.

COMMON ASSEMBLIES/MECHANICAL CONNECTIONS (UP TO 100A)/PVC - LT NM FLEX (CARFLEX)/20A 1PH MECH CONN (100') 3/4" PVC 3#12 - CARFLEX

"High-Lows"

COMMON ASSEMBLIES/TELECOM SYSTEMS/UNIT DATA - TELECOM/HIGH-LOW - TV SCOOP 1 1/2" ENT - NO CABLE

Eaton 35M2W

Telecom Homeruns

Included in MSDE.

Fire Alarm Devices

Residential

Smoke Detectors & CO Detectors

For smoke detectors and CO detectors where 120V (most common):

COMMON ASSEMBLIES/UNITS - MC CABLE ASSEMBLIES/GENERAL ASSEMBLIES - METAL STUD/UNIT SMOKE DETECTOR W/ CO DETECTOR ...

For ADA units:

COMMON ASSEMBLIES/UNITS - MC CABLE ASSEMBLIES/GENERAL ASSEMBLIES - METAL STUD/UNIT SMOKE DETECTOR / VISUAL SIGNAL ...

Additional Signaling Devices

==use free air devices==