Hello Team,
Below is a comprehensive list of means & methods for {Project Name}. Please confirm you have received this email and respond with any questions or comments.
- Delivery Method: %% Plans & Specs, Design Build, Design Assist, P&S with Approved VE %%
- Document Stage: %% DD, CD, Permit, GMP, Bid, Awarded %%
- Drawings Date: %% Date %%
- Project Manual Date: %% Date %%
- Proposal Date: %% Date %%
- Takeoff Request Stage: %% Stage 1, Full takeoff, etc. %%
Project Specification Callouts
%% Put page of Drawing or PM after answer %%
- Conduit Execution Plans: %% GRC, coupling specs, etc. %%
- Wire: %% Copper or Aluminum, Acceptable Manufacturers %%
- Cable Uses: %% Branch Homeruns %%
- Steel Box Depth: %% 1-1/2", 2-1/8" %%
- Floor Boxes:
- Box Material: %% Box: PVC, Sheet metal, Cast iron %%
- Cover Material: %% Covers: Brass, Aluminum %%
- Wiring Devices:
- Units: %% 15A Decora %%
- BOH/Common Areas: %% 20A Toggle %%
- Switchboards/Panelboards: %% Acceptable Manufacturers, AL or CU Bussing, Breaker Types (Snap-on, bolt on), ACI Ratings %%
- Transformers: %% Windings AL or CU, K-rating %%
- Generator: %% Acceptable manufacturers, Enclosure Specs, Sound Rating, Remote Tank, Tank Size, Load Banks %%
Project Drawing/Detail Callouts
-
Describe conflicts between drawings / proposal: %% "Plans show CU feeders, proposal calls for aluminum", Specification grade devices, etc. %%
-
Cost drivers in details not shown elsewhere on plans:
PDI System Execution Plan
- Primaries: %% Installation only, (9) 6" PVC %%
- Secondaries: %% PVC UG, GRC Stub-ups, AL %%
- Feeders: %% PVC UG, EMT OH, AL over 100A, 2% VD %%
- Unit Subfeeds: %% MC OH AL, VD per Chart on E5.01 %%
- Units: %% 15A Decora, Insinkerators, T-stat, Floor Boxes, Shade Control, Doorbells, Dimmer Switches, etc. %%
- Telecom: %% 42" MSDE, No Cable Homeruns, (1) 1" Back to IDF, CAT6 with Stub-ups %%
- EV Chargers: %% 42) Conduit only, (56) Conduit & Wire, (20) Conduit, Wire & Equipment %%
- Fire Alarm: %% Free-air where allowed by code. EMT Risers. %%
- DAS: %% Conduit only, Per PDI DAS Design %%
- Low Voltage: %% Free-air where allowed by code. Stub-ups to accessible ceilings. %%
Lighting Control
-
Scope: %% Code Minimum per Energy Code Assigned, P&S, PDI Design %%
-
Area: %% Assign Method to Areas: Line Voltage, Low-Voltage Stand Alone or Centralized System %%
- BOH:
- Corridor:
- Amenity:
- Site/Landscape:
- Garage Entry Point
- Office:
Tasks/Quotes Needed for WBS
- Electrical Constructability Review
- Electrical VDC
- Coordination Study %% Design Build: Not needed. %%
- DAS Public Safety Raceway Design
Thank you,