2.6 KiB
id, aliases, tags
| id | aliases | tags | |
|---|---|---|---|
|
Unit Takeoff
Info
"Units" includes #hotel and #residential spaces.
[!info] Americans with Disabilities Act (ADA) Terms
- hearing impaired (HI or H.I.)
- mobility features (MF or M.F.)
- accessible (Acc.)
- usually refers to mobility features.
Hotel
[!info] Also Known As
- Guestrooms
- Keys
[!trivia] The term "key" as a synonym of "hotel room" is a synecdoche, referring to the unit's door key. In the pre-digital days of hotel management, one could count the rooms of a hotel by the keys behind the front desk.
Residential
[!info] Also Known As
- Condos - resident-owned
- Apartments - resident-rented
Sequence
1. Estimate preparation
-
Locate Unit panels and relevant keynotes
- bus amps
-
Read about the project specifications and construction type
- wood or metal studs
- wiring methods
- NM or MC
- wiring device plates
- Decora or Standard
- wiring device specs
- are 15A devices allowed?
- equipment (20A Kitchen and bath)
- Fill out OneNote
Load Centers
| Rating | Assembly |
|---|---|
| <= 100A | DIST PANELS & UNIT LOAD CENTERS/UNIT LOAD CENTERS - .../... UNIT LOAD CENTER |
| > 100A | DIST PANELS & UNIT LOAD CENTERS/UNIT LOAD CENTERS - .../... BREAKER PNL |
Shade Control
"High-Lows"
COMMON ASSEMBLIES/TELECOM SYSTEMS/UNIT DATA - TELECOM/HIGH-LOW - TV SCOOP 1 1/2" ENT - NO CABLE
Air Sealing
- LEED Silver
- Draft Proof Box
- Mid-Atlantic jobs
ITEM DATABASE/BOSES & CABINETS/BOXES - VAPOR
COMMON ASSEMBLIES/UNITS - MC CABLE ASSEMBLIES/GENERAL ASSEMBLIES - METAL STUD/UNIT MISC ITEMS - MC - ADJUST ACCORDINGLY
Islands
COMMON ASSEMBLIES/UNITS - MC CABLE ASSEMBLIES/1x 15A 125V TR DUP DECORA (METAL STUD) - 20' 3/4" PVC, ENT, 3#12 THHN
2. Takeoff
[!tip] Preparing for Unit Takeoff Units generally have very little variation. It is usually best to copy-paste takeoffs rather than re-build them for each unit.
- Kitchen and Bath
- General assemblies
- Low Voltage
- Lighting Fixtures
- Lighting Control
Tip
It may be more efficient and neat to not copy switches, instead keeping the switch assembly list open and creating them new for each unit, since the types required can vary greatly between units.
3. Extension (Review and Checking)
- Scroll through with Area selected and make sure there is takeoff for each unit type