Unit Takeoff
[!info] See multi-family-dwellings.
Prerequisites
Important
Complete pre-takeoff-research, including wiring-method-selection and wiring-device-research, before beginning takeoff.
Takeoff
[!tip] Preparing for Unit Takeoff Units generally have very little variation. It is usually best to copy-paste takeoffs rather than re-build them for each unit.
- Load Center
- General assemblies
- Water Heater
- HVAC
- Laundry
- Kitchen
- Bathroom
- Low Voltage
- Lighting Fixtures
- Lighting Control
Tip
It may be more efficient and neat to not copy switches, instead keeping the switch assembly list open and creating them new for each unit, since the types required can vary greatly between units.
Tip
Consider using a "Typical - All Units" for scope identical between all unit types.
- WAP Outlets
- MSDE's
Load Centers
System= "EL - Electrical"
| Rating | Assembly |
|---|---|
| <= 100A | DIST PANELS & UNIT LOAD CENTERS/UNIT LOAD CENTERS - .../... UNIT LOAD CENTER |
| > 100A | DIST PANELS & UNIT LOAD CENTERS/UNIT LOAD CENTERS - .../... BREAKER PNL |
Include terminations per switchgear-takeoff.
Fixtures
Shade Control
VTAC Units
Used in lieu of individual split systems.
Dedicated Circuit Receptacles
For N5-15R/N5-20R receptacles serving fixed equipment such as:
- refrigerators
- gas ranges
- microwaves
- clothes washers
- hood fans
match the receptacle configuration shown on the plans (i.e. simplex to simplex, duplex to duplex).1
Air Sealing
- LEED Silver
- Mid-Atlantic jobs
- "Draft Proof Box"
ITEM DATABASE/BOXES & CABINETS/BOXES - VAPOR/...
COMMON ASSEMBLIES/UNITS - MC CABLE ASSEMBLIES/GENERAL ASSEMBLIES - METAL STUD/UNIT MISC ITEMS - MC - ADJUST ACCORDINGLY
Dishwasher/Disposal Receptacles
Even when drawings show 2 separate duplex receptacles,
use DW & DISPOSAL DUAL CIR - ...,
which includes only one receptacle.2
Disposal Switches
??? confirm If not air switch (check ID's) add single pole switch shown.
Islands
Use (1) SLAB / DECK receptacle for every 2 circuits in the island.
COMMON ASSEMBLIES/UNITS - MC CABLE ASSEMBLIES/... RECEPTACLE TAMPER RESISTANT .../... (METAL STUD) - 20' 3/4" PVC, ENT, 3#12 THHN
Use standard MC assemblies for remaining devices.
Bidet Toilets, Whirlpool Baths, etc.
COMMON ASSEMBLIES/MECHANICAL CONNECTIONS (UP TO 100A)/PVC - LT NM FLEX (CARFLEX)/20A 1PH MECH CONN (100') 3/4" PVC 3#12 - CARFLEX
"High-Lows"
Empty in-wall pass through from credenza location to behind television location.
COMMON ASSEMBLIES/TELECOM SYSTEMS/UNIT DATA - TELECOM/HIGH-LOW - TV SCOOP 1 1/2" ENT - NO CABLE
Eaton 35M2W
Doorbells
???
HANDICAP DB W/SINGLE HORN/STROBE - 12/2c MC CABLE
Telecom Homeruns
Residential
Included in MSDE.
Key
COMMON ASSEMBLIES/TELECOM SYSTEMS/BOH AMENITY ASSEMBLIES/...
Adjust cable length as needed.
Fire Alarm Devices
Residential
System= "EL - Electrical"
Smoke Detectors & CO Detectors
For smoke detectors and CO detectors where 120V (most common):
COMMON ASSEMBLIES/UNITS - MC CABLE ASSEMBLIES/GENERAL ASSEMBLIES - METAL STUD/UNIT SMOKE DETECTOR W/ CO DETECTOR ...
For ADA units:
COMMON ASSEMBLIES/UNITS - MC CABLE ASSEMBLIES/GENERAL ASSEMBLIES - METAL STUD/UNIT SMOKE DETECTOR / VISUAL SIGNAL ...
Additional Signaling Devices
System= "FA - Fire Alarm"
COMMON ASSEMBLIES/FIRE ALARM & DAS SYSTEMS/INDICATING DEVICES WITH WIRE - FREE AIR/INDOOR HORN STROBE - FREE AIR
Hospitality
System= "FA - Fire Alarm"
COMMON ASSEMBLIES/FIRE ALARM & DAS SYSTEMS/... DEVICES WITH WIRE - FREE AIR
-
2026-01-12_10-42-30#Unit Dishwasher/Disposal ↩︎