Hilltop Gardens Pre-Takeoff Email
%% Implementation of conest-pre-takeoff-email-template for hilltop-gardens. %%
Hello Team,
Below is a comprehensive list of means & methods for Hilltop Gardens. Please confirm you have received this email and respond with any questions or comments.
- Delivery Method: Plans & Specs %% Plans & Specs, Design Build, Design Assist, P&S with Approved VE %%
- Document Stage: Permit %% DD, CD, Permit, GMP, Bid, Awarded %%
- Drawings Date: 2025-12-12 %% Date %%
- Project Manual Date: N/A %% Date %%
- Proposal Date: 2026-04-16 %% Date %%
- Takeoff Request Stage: Full Takeoff %% Stage 1, Full takeoff, etc. %%
Project Specification Callouts
%% Put page of Drawing or PM after answer %%
-
Conduit Execution Plans:
- EMT Fittings: Not specified.
- Rigid elbows where stubbing up from grade. ---E.0.X.1 "ELECTRICAL NOTES" Notes 53, 54
- PVC slab-on-grade, below grade only. ---E.0.X.1 "ELECTRICAL NOTES" Note 32 %% GRC, coupling specs, etc. %%
-
Wire: AL 1 AWG and above. ---E.4.X.X "WIRE SCHEDULE KEY NOTE" %% Copper or Aluminum, Acceptable Manufacturers %%
-
Cable Uses: Devices only, homeruns in conduit. ---E.0.X.1 - "ELECTRICAL NOTES" Note 27 %% Branch Homeruns %%
-
Steel Box Depth: Not specified. %% 1-1/2", 2-1/8" %%
-
Floor Boxes: ---E.0.X.1 "ELECTRICAL NOTES" Notes 53, 54
- Box Material: Hubbell B-2529 (stamped steel). %% Box: PVC, Sheet metal, Cast iron %%
- Cover Material: Hubbell S-3725 (brass). %% Covers: Brass, Aluminum %%
-
Wiring Devices: All 20A Toggle/Duplex. ---E.0.X.1 "ELECTRICAL NOTES" Note 45
-
Switchboards/Panelboards: %% Acceptable Manufacturers, AL or CU Bussing, Breaker Types (Snap-on, bolt on), ACI Ratings %%
- Bus Material: Copper. ---E.0.X.1 "ELECTRICAL NOTES" Notes 66(G), 67(G)
- Breaker Type:
- General Panelboards: Bolt-On. ---E.0.X.1 "ELECTRICAL NOTES" Note 66(E)
- Unit Load Centers: Plug-In. ---E.0.X.1 "ELECTRICAL NOTES" Note 67(E)
- Interrupting Current Ratings: "ALL BREAKERS SHALL BE SERIES RATED AT 22K TO THE MAIN BREAKER. MAIN BREAKER AIC RATING IS 65K. UNIT APARTMENT PANELBOARD MAIN BREAKER AIC RATING 10K." ---E.4.X.1 "RISER NOTES" Note (B)
-
Transformers:
- Winding Material: Not specified.
- K-Rating: Not specified. %% Windings AL or CU, K-rating %%
-
Generator: N/A. %% Acceptable manufacturers, Enclosure Specs, Sound Rating, Remote Tank, Tank Size, Load Banks %%
Project Drawing/Detail Callouts
-
Describe conflicts between drawings / proposal: %% "Plans show CU feeders, proposal calls for aluminum", Specification grade devices, etc. %%
-
Cost drivers in details not shown elsewhere on plans:
PDI System Execution Plan
-
Primaries: (2) 4"C install only. Wiring excluded. ---Proposal 2026-04-16 %% Installation only, (9) 6" PVC %%
-
Secondaries: PVC with RMC stub-ups. AL wiring. %% PVC UG, GRC Stub-ups, AL %%
-
Feeders: PVC in-slab, below grade; EMT OH. AL over 100A. 2% VD. %% PVC UG, EMT OH, AL over 100A, 2% VD %%
-
Unit Subfeeds: PVC in-slab. AL wiring. 2% VD. %% MC OH AL, VD per Chart on E5.01 %%
-
Units: 20A toggle/duplex, USB rec's, disposals, thermostat wiring. %% 15A Decora, Insinkerators, T-stat, Floor Boxes, Shade Control, Doorbells, Dimmer Switches, etc. %%
-
Telecom: (4) 4"C each building. (2) 4"C riser each building. 1"C to each unit. Assuming 28" MSDE's. %% 42" MSDE, No Cable Homeruns, (1) 1" Back to IDF, CAT6 with Stub-ups %%
-
EV Chargers: (12) conduit, wire, equipment. %% (42) Conduit only, (56) Conduit & Wire, (20) Conduit, Wire & Equipment %%
-
Fire Alarm: PVC in-slab, below grade. 120V smokes in units. %% Free-air where allowed by code. EMT Risers. %%
-
DAS: Sleeving and pathways only. %% Conduit only, Per PDI DAS Design %%
-
Low Voltage: All pathways, conduit, wiring, equipment excluded. %% Free-air where allowed by code. Stub-ups to accessible ceilings. %%
Lighting Control
-
Scope: Per plans. %% Code Minimum per Energy Code Assigned, P&S, PDI Design %%
-
Area: %% Assign Method to Areas: Line Voltage, Low-Voltage Stand Alone or Centralized System %%
- BOH: Line voltage.
- Corridor: Digital standalone.
- Amenity: Line voltage.
- Site/Landscape: Line voltage.
- Garage: Line voltage.
Tasks/Quotes Needed for WBS
- ==Switchgear Quote==
- Electrical Constructability Review
- Electrical VDC
- Coordination Study %% Design Build: Not needed. %%
- DAS Public Safety Raceway Design