vault backup: 2025-11-11 17:19:52
This commit is contained in:
@@ -33,3 +33,26 @@ facts of our role:
|
|||||||
In these ways we're actually more like court
|
In these ways we're actually more like court
|
||||||
wizards than artists, which is an understandably
|
wizards than artists, which is an understandably
|
||||||
desirable position.
|
desirable position.
|
||||||
|
|
||||||
|
## 2025-11-11 14:41
|
||||||
|
|
||||||
|
I just saw a post on a construction estimators forum
|
||||||
|
from a user lamenting that their coworkers and customers
|
||||||
|
largely do not understand the difference between markup and margin.
|
||||||
|
|
||||||
|
It made me remember the micro-debates about that I would have with Dale
|
||||||
|
every time we were closing out an estimate.
|
||||||
|
This is the example I would always give
|
||||||
|
while trying to explain it to him.
|
||||||
|
|
||||||
|
![[markup-vs-margin]]
|
||||||
|
|
||||||
|
***
|
||||||
|
|
||||||
|
The user also stated that they would prefer to list overhead and profit
|
||||||
|
separately from scope line item costs,
|
||||||
|
but that their customers push back when they try.
|
||||||
|
|
||||||
|
I'm not sure where they got this preference.
|
||||||
|
Sure that would be more "transparent",
|
||||||
|
but it's at odds with the purpose of a breakdown.
|
||||||
|
|||||||
@@ -38,9 +38,11 @@ Match Fire Alarm takeoff Length and Count
|
|||||||
|
|
||||||
### Stairwell Riser Every 2 Floors
|
### Stairwell Riser Every 2 Floors
|
||||||
|
|
||||||
`Area` = "Typical - Building Even Levels"
|
> [!info] Takeoff
|
||||||
|
> * `Area` = "Typical - Building Even Levels"
|
||||||
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`DAS ASSEMBLIES`/`STAIRWELL RISER EVERY 2 FLRS = ...`
|
>
|
||||||
|
> 1. `COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`DAS ASSEMBLIES`/`STAIRWELL RISER EVERY 2 FLRS = ...`
|
||||||
|
> * **Count** = Each stairwell
|
||||||
|
|
||||||
### FACR to Electric Room
|
### FACR to Electric Room
|
||||||
|
|
||||||
@@ -56,9 +58,9 @@ Takeoff in every Electric Room
|
|||||||
|
|
||||||
### Top 2H Rated Room To Roof
|
### Top 2H Rated Room To Roof
|
||||||
|
|
||||||
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`DAS ASSEMBLIES`/`TOP 2HR RATED RM TO ROOF = ...`
|
> [!info] Takeoff
|
||||||
|
> 1. `COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`DAS ASSEMBLIES`/`TOP 2HR RATED RM TO ROOF = ...`
|
||||||
* **Length** = 15ft or height of ceiling on last building level
|
> * **Length** = 15ft or height of ceiling on last building level
|
||||||
|
|
||||||
## Horizontal
|
## Horizontal
|
||||||
|
|
||||||
@@ -66,6 +68,6 @@ Takeoff in every Electric Room
|
|||||||
> Usually only for cellular DAS.
|
> Usually only for cellular DAS.
|
||||||
> Confirm takeoff requirement with [[pdi-estimating#Bid Estimating|Bid]].
|
> Confirm takeoff requirement with [[pdi-estimating#Bid Estimating|Bid]].
|
||||||
|
|
||||||
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`DAS ASSEMBLIES`/`CORRIDORS ...`
|
> [!info] Takeoff
|
||||||
|
> 1. `COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`DAS ASSEMBLIES`/`CORRIDORS ...`
|
||||||
* **Length** = Length measured for every corridor/garage
|
> * **Length** = Length measured for every corridor/garage
|
||||||
|
|||||||
@@ -58,7 +58,7 @@ For each Elevator Control Room (ECR):
|
|||||||
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`FACR TO ELEV CONTROL RM ...`
|
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`FACR TO ELEV CONTROL RM ...`
|
||||||
|
|
||||||
* **Length** = Length measured from the most distant points of the FACR and ECR.
|
* **Length** = Length measured from the most distant points of the FACR and ECR.
|
||||||
* Input adder length to reach the level of the ECR (Minimum 15ft).
|
* Input adder length to reach the level of the ECR (Minimum 15ft).
|
||||||
|
|
||||||
### Elevator Shafts
|
### Elevator Shafts
|
||||||
|
|
||||||
|
|||||||
@@ -237,7 +237,7 @@ Create its own breakout in WBS, and phase in Accubid
|
|||||||
## Site & Courtyard
|
## Site & Courtyard
|
||||||
|
|
||||||
> [!important]
|
> [!important]
|
||||||
> Coordinate with landscape
|
> Coordinate with landscape drawings
|
||||||
|
|
||||||
### Breakdowns
|
### Breakdowns
|
||||||
|
|
||||||
@@ -245,7 +245,8 @@ Create its own breakout in WBS, and phase in Accubid
|
|||||||
|
|
||||||
### Pole Lights
|
### Pole Lights
|
||||||
|
|
||||||
`FIXTURE ACCESSORIES`/`SITE POLE ASSEMBLIES`/...
|
> [!info] Takeoff
|
||||||
|
> 1. `FIXTURE ACCESSORIES`/`SITE POLE ASSEMBLIES`/...
|
||||||
|
|
||||||
Add subassemblies for stub-outs, pole, base, and grounding as appropriate.
|
Add subassemblies for stub-outs, pole, base, and grounding as appropriate.
|
||||||
|
|
||||||
@@ -256,9 +257,12 @@ Add subassemblies for stub-outs, pole, base, and grounding as appropriate.
|
|||||||
> * market lighting
|
> * market lighting
|
||||||
> * catenary lighting
|
> * catenary lighting
|
||||||
|
|
||||||
|
> [!info] Takeoff
|
||||||
> 1. `FIXTURE LABOR`/`FIXTURE LABOR 2HR`
|
> 1. `FIXTURE LABOR`/`FIXTURE LABOR 2HR`
|
||||||
|
>
|
||||||
> 2. `FESTOON & ROOF ASSEMBLIES`/`FESTOON CABLE HANGER & EYE BOLTS - LENGTH`
|
> 2. `FESTOON & ROOF ASSEMBLIES`/`FESTOON CABLE HANGER & EYE BOLTS - LENGTH`
|
||||||
> * **Length per Unit** = Light string length
|
> * **Length per Unit** = Light string length
|
||||||
|
>
|
||||||
> 3. `COURTYARDS & LANDSCAPE`/`ALUM BOX W/ FLEX FIX, 3/4" CONDUIT - PVC40 - ...`
|
> 3. `COURTYARDS & LANDSCAPE`/`ALUM BOX W/ FLEX FIX, 3/4" CONDUIT - PVC40 - ...`
|
||||||
> * **Length per Unit** = Distance to panel + 15ft
|
> * **Length per Unit** = Distance to panel + 15ft
|
||||||
|
|
||||||
@@ -273,9 +277,10 @@ Add subassemblies for stub-outs, pole, base, and grounding as appropriate.
|
|||||||
| Fixtures built into cabanas/pergolas | .../`ALUM BOX W/ FLEX FIX, 3/4" CONDUIT - PVC40 - ...` |
|
| Fixtures built into cabanas/pergolas | .../`ALUM BOX W/ FLEX FIX, 3/4" CONDUIT - PVC40 - ...` |
|
||||||
| Handrail light | .../`ALUM BOX W/ FLEX FIX, 3/4" CONDUIT - PVC40, IMC ELBOW - ...` |
|
| Handrail light | .../`ALUM BOX W/ FLEX FIX, 3/4" CONDUIT - PVC40, IMC ELBOW - ...` |
|
||||||
|
|
||||||
[^2]: If we don't own concrete, delete Pre-cast bollard base from assembly
|
[^2]: If we don't own concrete, delete pre-cast bollard base from assembly
|
||||||
|
|
||||||
## FAA Lighting
|
## FAA Lighting
|
||||||
|
|
||||||
|
> [!info] Takeoff
|
||||||
> 1. `FIXTURE LABOR`/`FIXTURE LABOR 1HR`
|
> 1. `FIXTURE LABOR`/`FIXTURE LABOR 1HR`
|
||||||
> 2. `FESTOON & ROOF ASSEMBLIES`/`Aircraft Warning, 3/4" Conduit GRC/PVC 2#10, 1#10G`
|
> 2. `FESTOON & ROOF ASSEMBLIES`/`Aircraft Warning, 3/4" Conduit GRC/PVC 2#10, 1#10G`
|
||||||
|
|||||||
@@ -0,0 +1,29 @@
|
|||||||
|
---
|
||||||
|
id:
|
||||||
|
aliases: []
|
||||||
|
tags: []
|
||||||
|
title: Markup vs. Margin
|
||||||
|
---
|
||||||
|
# Markup vs. Margin
|
||||||
|
|
||||||
|
$$
|
||||||
|
\text{Profit} = \text{Sell Price} - \text{Cost}, \quad
|
||||||
|
\text{Markup} = \frac{\text{Profit}}{\text{Cost}}, \quad
|
||||||
|
\text{Margin} = \frac{\text{Profit}}{\text{Sell Price}}
|
||||||
|
$$
|
||||||
|
|
||||||
|
Suppose a product that
|
||||||
|
* costs $80 to produce
|
||||||
|
* is sold for $100
|
||||||
|
|
||||||
|
$$
|
||||||
|
\text{Profit} = 100 - 80 = 20, \quad
|
||||||
|
\text{Markup} = \frac{20}{80} = 25\%, \quad
|
||||||
|
\text{Margin} = \frac{20}{100} = 20\%
|
||||||
|
$$
|
||||||
|
|
||||||
|
Because of \*waves hands\* finance reasons,
|
||||||
|
contractors (and sellers of products and services in general)
|
||||||
|
almost exclusively talk about profit in terms of margin.
|
||||||
|
Even if someone says "15% _markup_"
|
||||||
|
they're still probably talking about margin.
|
||||||
@@ -0,0 +1,5 @@
|
|||||||
|
# Uncommon Syntax
|
||||||
|
|
||||||
|
* **i.e.** --- _id est_ ("that is")
|
||||||
|
|
||||||
|
* **e.g.** --- _exempli gratia_ ("for example")
|
||||||
+12
-11
@@ -55,17 +55,18 @@ Used in lieu of individual split systems.
|
|||||||
|
|
||||||
### Dedicated Circuit Receptacles
|
### Dedicated Circuit Receptacles
|
||||||
|
|
||||||
For N5-15R/N5-20R receptacles serving fixed equipment such as:
|
> [!quote] Joel Jansen 2025-11-11, pp.
|
||||||
|
>
|
||||||
* refrigerators
|
> For N5-15R/N5-20R receptacles serving fixed equipment such as:
|
||||||
* gas ranges
|
>
|
||||||
* microwaves
|
> * refrigerators
|
||||||
* clothes washers
|
> * gas ranges
|
||||||
* hood fans
|
> * microwaves
|
||||||
|
> * clothes washers
|
||||||
use single receptacle assemblies, even where shown as duplex.
|
> * hood fans
|
||||||
|
>
|
||||||
`COMMON ASSEMBLIES`/`UNITS - MC CABLE ASSEMBLIES`/`KITCHEN & BATH ASSEMBLIES - METAL STUD`/`SGL REC ...`
|
> match the receptacle configuration shown on the plans
|
||||||
|
> (i.e. simplex to simplex, duplex to duplex).
|
||||||
|
|
||||||
### Air Sealing
|
### Air Sealing
|
||||||
|
|
||||||
|
|||||||