vault backup: 2025-11-11 12:22:56
This commit is contained in:
Vendored
+2
-1
@@ -13,5 +13,6 @@
|
||||
"obsidian-latex-suite",
|
||||
"obsidian-pretty-bibtex",
|
||||
"obsidian-tikzjax",
|
||||
"lilypond"
|
||||
"lilypond",
|
||||
"novel-word-count"
|
||||
]
|
||||
+1
-1
@@ -32,7 +32,7 @@ today. They have absurdly large feet, moorso the juveniles.\*
|
||||
\*The common gallinule was formerly known as the common moorhen, only split from
|
||||
the Old World species (_Gallinula chloropus_) in July 2011. It may still be more
|
||||
widely known as "moorhen" , thus the pun.
|
||||
Today was a good day---I've been at this for a while, one second.
|
||||
Today was a good day---I've been at this for a while, one second...
|
||||
|
||||
## 2025-10-31 19:48 --- Late Friday Evening, Halloween btw
|
||||
|
||||
|
||||
+3
-5
@@ -29,15 +29,13 @@ Now I feel myself sour when I see the same warning signs.
|
||||
> is a fleeting vapor and a deadly snare
|
||||
|
||||
> [!quote] Robert Palmer, "Every Kinda People"
|
||||
> There is no profit in deceit
|
||||
>
|
||||
> Honest men know that
|
||||
>
|
||||
> There is no profit in deceit \
|
||||
> Honest men know that \
|
||||
> Revenge does not taste sweet
|
||||
|
||||
When you bill your customer to provide scope
|
||||
that they thought they already paid for,
|
||||
they don't say "Touche" and move on,
|
||||
they don't say "Touché" and move on,
|
||||
they ask themselves what they've done for you,
|
||||
what they're doing, and if you still deserve it.
|
||||
**You are cashing out on good will.**
|
||||
|
||||
+36
-8
@@ -4,8 +4,8 @@ aliases: []
|
||||
tags:
|
||||
- authorship/original
|
||||
- destiny/permanent
|
||||
- original-format/typewritten-print
|
||||
- original-format/digital-text
|
||||
- original-format/typewritten-print
|
||||
- type/daily
|
||||
title: 2025-11-10
|
||||
---
|
||||
@@ -55,19 +55,19 @@ when I noticed a strange paragraph:
|
||||
>
|
||||
> Drop down ceiling is technically "Exposed" (the real term should be accessable),
|
||||
> so Romex and SER is not permited. Will need to use MC.
|
||||
>
|
||||
>
|
||||
> > [!image]
|
||||
> > ### 334.12 Uses Not Permitted.
|
||||
> >
|
||||
> >
|
||||
> > #### 334.12(A) Types NM and NMC.
|
||||
> >
|
||||
> >
|
||||
> > Types NM and NMC cables shall not be permitted as follows:
|
||||
> >
|
||||
> >
|
||||
> > 1. In any dwelling or structure not specifically
|
||||
> > permitted in 334.10(1), (2), (3)
|
||||
> > permitted in 334.10(1), (2), (3)
|
||||
> >
|
||||
> > 2. ==Exposed in dropped or suspended ceilings==
|
||||
> > in other than one- and two-family and multifamily dwellings
|
||||
> > in other than one- and two-family and multifamily dwellings
|
||||
|
||||
This analysis of 334.12(A)(2) is flawed.
|
||||
|
||||
@@ -84,7 +84,7 @@ can be paraphrased as follows:
|
||||
> in accessible spaces above suspended ceilings,
|
||||
> _except in buildings containing one or more dwelling units._
|
||||
|
||||
The prohibition of 334.12(A)(2) *never* applies to apartments or condos,
|
||||
The prohibition of 334.12(A)(2) _never_ applies to apartments or condos,
|
||||
And only applies to hotels and dormitories on a basis of AHJ interpretation
|
||||
(See [[multi-family-dwellings#Are Hotels Multifamily Dwellings?]]).
|
||||
|
||||
@@ -106,3 +106,31 @@ I'm certain I misuse it frequently.
|
||||
It _does not_ include power conductors to
|
||||
[[nfpa-70_100_definitions#Utilization Equipment.|utilization equipment]],
|
||||
those are a [[nfpa-70_100_definitions#Branch Circuit.|branch circuit]]
|
||||
|
||||
## 2025-11-10 20:00 --- Monday Evening, Before Bed
|
||||
|
||||
Today while (a peer) and I were walking, he asked
|
||||
me what I thought of his qualities as an estimator.
|
||||
I told him I think he has the right of it, that having beliefs
|
||||
about what's correct that don't change just because
|
||||
a senior says they should, is a good sign.
|
||||
|
||||
I can't remember now if I knew it before today,
|
||||
but my relationship with Dale, my former manager,
|
||||
while never "good", was much improved when I started
|
||||
pushing back on his direction and feedback. I became
|
||||
an estimator where before I was just someone who
|
||||
could estimate for him. He hated it, and let me know,
|
||||
but I never felt more sure of my position.
|
||||
|
||||
Estimating is not a field where you get ahead
|
||||
by being more technically skilled or efficient.
|
||||
|
||||
You distinguish yourself by convincing your superiors
|
||||
that you understand the objective and how to achieve
|
||||
it. The best estimators---as measured by compensation
|
||||
package---are not doing takeoff, they're
|
||||
telling other estimators what to take off and how.
|
||||
|
||||
Conquer your self-doubt. Tell your boss they're
|
||||
wrong and stupid and they should feel bad. Profit.
|
||||
|
||||
@@ -0,0 +1,35 @@
|
||||
---
|
||||
id:
|
||||
aliases: []
|
||||
tags:
|
||||
- authorship/original
|
||||
- destiny/permanent
|
||||
- original-format/typewritten-print
|
||||
- type/daily
|
||||
title: 2025-11-11
|
||||
---
|
||||
# 2025-11-11
|
||||
|
||||
## 2025-11-11 06:06 --- Tuesday Morning, Before Work
|
||||
|
||||
One of the most appealing aspects of estimating
|
||||
to me is the dynamic we have with our employers.
|
||||
my experience was at Ace that estimators act like,
|
||||
and are treated like good artists, like loveable
|
||||
little-scamps who always get into trouble, but
|
||||
you keep them around because they do good work.
|
||||
There was no other position with a similar reputation.
|
||||
|
||||
I attribute this strange relationship to two
|
||||
facts of our role:
|
||||
|
||||
1. Estimating provides executives with a service,
|
||||
one that they could almost do without, but that they
|
||||
understand the value of paying for.
|
||||
|
||||
2. Estimating is just math-heavy enough that it
|
||||
seems like magic to the uninitiated.
|
||||
|
||||
In these ways we're actually more like court
|
||||
wizards than artists, which is an understandably
|
||||
desirable position.
|
||||
+34
-24
@@ -45,7 +45,22 @@ Include [[sleeving-takeoff]] as necessary.
|
||||
|
||||
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`FIRE PUMP ROOM ...`
|
||||
|
||||
### FACR to Elevator Shafts
|
||||
### Elevator Control Rooms
|
||||
|
||||
> Also "Elevator Machine Room"
|
||||
|
||||
For each Elevator Control Room (ECR):
|
||||
|
||||
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`ELEV CONTROL ROOM ...`
|
||||
|
||||
* **Count** = 1
|
||||
|
||||
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`FACR TO ELEV CONTROL RM ...`
|
||||
|
||||
* **Length** = Length measured from the most distant points of the FACR and ECR.
|
||||
* Input adder length to reach the level of the ECR (Minimum 15ft).
|
||||
|
||||
### Elevator Shafts
|
||||
|
||||
`Area` = Same as FACR
|
||||
|
||||
@@ -73,19 +88,6 @@ For each elevator shaft:
|
||||
> | 1 shaft | 2 shafts |
|
||||
> ```
|
||||
|
||||
### FACR to Elevator Control Rooms
|
||||
|
||||
For each Elevator Control Room (ECR):
|
||||
|
||||
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`ELEV CONTROL ROOM ...`
|
||||
|
||||
* **Count** = 1
|
||||
|
||||
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`FACR TO ELEV CONTROL RM ...`
|
||||
|
||||
* **Length** = Length measured from the most distant points of the FACR and ECR.
|
||||
* Input adder length to reach the level of the ECR (Minimum 15ft).
|
||||
|
||||
### FACR to Stairwells
|
||||
|
||||
> [!info]
|
||||
@@ -98,7 +100,7 @@ For each stairwell:
|
||||
* **Length** = Length measured from the most distant points of the FACR and stairwell.
|
||||
* Input adder length to reach the level of the stairwell (Minimum 15ft).
|
||||
|
||||
### Terminal Cabinets
|
||||
## Terminal Cabinets
|
||||
|
||||
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`TERMINAL CABINET`/`ACE D ACCESSORY CABINET ENCLOSURE ...`
|
||||
|
||||
@@ -107,25 +109,33 @@ For each stairwell:
|
||||
|
||||
Horizontal:
|
||||
|
||||
`Area` = Same as FACR
|
||||
|
||||
* **Length** = Length measured from FACR to all electrical rooms
|
||||
> * `Area` = Same as FACR
|
||||
> * **Length** = Length measured from FACR to all electrical rooms
|
||||
|
||||
Vertical:
|
||||
|
||||
`Area` = "Typical - Building All Levels"
|
||||
> * `Area` = "Typical - Building All Levels"
|
||||
> * **Length** = 10ft
|
||||
|
||||
* **Length** = 10ft
|
||||
|
||||
### Annunciator Panels
|
||||
## Annunciator Panels
|
||||
|
||||
> [!info] Also Known As
|
||||
> * Fire Alarm Annunciator (FAA)
|
||||
> * Fire Alarm Annunciator Panel (FAAP)
|
||||
|
||||
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`ANNUNCIATORS`/`REMOTE SERIAL ANNUNCIATOR ...`
|
||||
> `COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`ANNUNCIATORS`/`REMOTE SERIAL ANNUNCIATOR ...`
|
||||
> * **Length** = Length measured from the FACR to FAA or Lobby
|
||||
|
||||
**Length** = Length measured from the FACR to FAA or Lobby
|
||||
## Central Monitoring Loop
|
||||
|
||||
> [!important]
|
||||
> Garden Style only.
|
||||
|
||||
> Fire Alarm Control Panels from each building will send a signal to a central location.
|
||||
>
|
||||
> In case of an emergency,
|
||||
> the fire department will go to the central fire alarm station
|
||||
> and find out what the issue is.
|
||||
|
||||
## Devices
|
||||
|
||||
|
||||
+21
-19
@@ -19,11 +19,11 @@ for use in [[fixtures-takeoff]].
|
||||
### Format
|
||||
|
||||
```regex
|
||||
<phase-abbr> - <assembly>(\: <subtype>)?( - <fixture-labor>)? \(<wiring-method>\)( <wm-descriptor>)* <branch-length>ft
|
||||
<phase-abbr> - <assembly>(\: <assembly-subtype>)?( = <fixture-labor>)? <wiring-method> <branch-length>ft
|
||||
```
|
||||
|
||||
> [!example]
|
||||
> `A - Surface: Pendant - 2.0hrs (MC) LV 20ft`
|
||||
> `A - Surface: Pendant = 2.0hrs - #12 MC+LV 20ft`
|
||||
|
||||
## Order
|
||||
|
||||
@@ -67,7 +67,7 @@ Use empty designations to separate phases.
|
||||
| Exterior Amenity | 50ft |
|
||||
| Units | 20ft |
|
||||
| Undercabinet Fixtures | 10ft |
|
||||
| Stairwells | ? |
|
||||
| Stairwells | 20ft |
|
||||
| Kitchen | ? |
|
||||
|
||||
Reduce as appropriate.
|
||||
@@ -89,26 +89,24 @@ Reduce as appropriate.
|
||||
|
||||
Use ENT assemblies unless forbidden by spec.
|
||||
|
||||
`FIXTURE ACCESSORIES`/`PVC/ENT ASSEMBLIES`/`GARAGE FIXTURE ENT W/#10 - STEEL OCT RING`
|
||||
|
||||
`FIXTURE ACCESSORIES`/`PVC/ENT ASSEMBLIES`/`GARAGE FIXTURE W/T ROD ENT W/#10 - STEEL OCT RING`
|
||||
|
||||
Use threaded rod assemblies in I-beam/precast garages.
|
||||
| Case | Assembly Path (`FIXTURE ACCESSORIES`/`PVC/ENT ASSEMBLIES`/...) |
|
||||
| ----------------- | -------------------------------------------------------------- |
|
||||
| Conventional Slab | .../`GARAGE FIXTURE ENT W/#10 - STEEL OCT RING` |
|
||||
| Precast/I-Beam | .../`GARAGE FIXTURE W/T ROD ENT W/#10 - STEEL OCT RING` |
|
||||
|
||||
If PVC is required, use following assemblies:
|
||||
|
||||
| Case | Assembly Path |
|
||||
| ------- | ------------------------------------------------------------------------------------------------ |
|
||||
| Ceiling | `FIXTURE ACCESSORIES`/`PVC/ENT ASSEMBLIES`/`... - SLAB BOX / 45 DEG STUBBY` |
|
||||
| Wall | `FIXTURE ACCESSORIES`/`PVC/ENT ASSEMBLIES`/`... - STL BOX & TILE RING / 45 DEG STUBBY/ ENT DROP` |
|
||||
| Case | Assembly Path (`FIXTURE ACCESSORIES`/`PVC/ENT ASSEMBLIES`/...) |
|
||||
| ------- | -------------------------------------------------------------- |
|
||||
| Ceiling | .../`... - SLAB BOX / 45 DEG STUBBY` |
|
||||
| Wall | .../`... - STL BOX & TILE RING / 45 DEG STUBBY/ ENT DROP` |
|
||||
|
||||
### Homeruns
|
||||
|
||||
> * `System` = "EL - Electrical"
|
||||
> `COMMON ASSEMBLIES`/`Device Homeruns in Slab/Deck`
|
||||
|
||||
Use 1 Homerun for every 3 circuits in Garage
|
||||
|
||||
Use assembly `COMMON ASSEMBLIES`/`Device Homeruns in Slab/Deck`
|
||||
Use 1 homerun for every 3 circuits in Garage
|
||||
|
||||
## Surface Mount
|
||||
|
||||
@@ -207,6 +205,10 @@ round up to the nearest 5ft
|
||||
| MC Cable | `MC ASSEMBLIES`/`FAN RATED OCT BOX W/ BAR HNGR - ...` |
|
||||
| PVC | `PVC/ENT ASSEMBLIES`/`... - SLAB BOX / 45 DEG STUBBY` |
|
||||
|
||||
## Guardrail Fixtures
|
||||
|
||||
`FIXTURE ACCESSORIES`/`COURTYARDS & LANDSCAPE`/`ALUM BOX W/ FLEX FIX, 3/4" CONDUIT - PVC40 - ...`
|
||||
|
||||
## Stairwells & Elevators
|
||||
|
||||
`PVC/ENT ASSEMBLIES`/`... - SLAB BOX / 45 DEG STUBBY`
|
||||
@@ -217,10 +219,10 @@ round up to the nearest 5ft
|
||||
|
||||
Length and Labor will be more than a normal fixture in BOH/Amenity
|
||||
|
||||
| Fixture Type | Labor (hrs) |
|
||||
| ------------ | ----------------------------------- |
|
||||
| Non-Linear | 2 |
|
||||
| Linear | [See tape lighting](#Tape Lighting) |
|
||||
| Fixture Type | Labor |
|
||||
| ------------ | ---------------------- |
|
||||
| Non-Linear | 2hrs |
|
||||
| Linear | See [[#Tape Lighting]] |
|
||||
|
||||
> 1. `3/4" PVC W/ 3#10 - STL BOX & TILE RING / 45 DEG STUBBY/ ENT DROP`
|
||||
> * `Length per Unit` = Distance to panel
|
||||
|
||||
+4
-1
@@ -26,7 +26,8 @@ title: Full Takeoff
|
||||
### 2. Takeoff
|
||||
|
||||
> [!important] Disclaimer
|
||||
> [[takeoff-strategy-comparison]]
|
||||
> These scripts are intended to cover all cases, but may not.
|
||||
> Variations should be corrected.
|
||||
|
||||
#### Stage 1
|
||||
|
||||
@@ -45,6 +46,8 @@ title: Full Takeoff
|
||||
10. [[standalone-systems-takeoff]]
|
||||
11. [[misc-budgets-takeoff]]
|
||||
|
||||
[[general-takeoff]]
|
||||
|
||||
### 3. Review
|
||||
|
||||
1. [[takeoff-review]]
|
||||
|
||||
@@ -0,0 +1,19 @@
|
||||
---
|
||||
id:
|
||||
aliases: []
|
||||
tags:
|
||||
- authorship/original
|
||||
- destiny/permanent
|
||||
- occupational/takeoff
|
||||
- status/draft
|
||||
- type/guide
|
||||
title: General Takeoff
|
||||
---
|
||||
# General Takeoff
|
||||
|
||||
This note is for all takeoff sub-scripts
|
||||
intended to be referenced by multiple top-level systems.
|
||||
|
||||
* [[fire-resistive-wiring-methods-takeoff]]
|
||||
* [[heating-designations]]
|
||||
* [[sleeving-takeoff]]
|
||||
+33
-11
@@ -21,7 +21,7 @@ title: Switchgear
|
||||
* Generators
|
||||
* Transfer switches
|
||||
* Generator connection cabinets
|
||||
* CT cabinet
|
||||
* CT cabinets
|
||||
* Power monitor
|
||||
|
||||
2. Takeoff Common Assemblies:
|
||||
@@ -47,7 +47,15 @@ add terminations according to an example from the schedules.
|
||||
> * Grounding
|
||||
> * Elevator Room
|
||||
|
||||
## SPD's/TVSS's
|
||||
## By Equipment Type
|
||||
|
||||
> [!tip] When in Doubt
|
||||
> If the equipment is not listed below,
|
||||
> use a distribution panel of equal amps.
|
||||
|
||||
### SPD's/TVSS's
|
||||
|
||||
> Name = "SPD"
|
||||
|
||||
Labor only.
|
||||
|
||||
@@ -56,37 +64,51 @@ Specific item is not important, but I use
|
||||
(Labor = 1.5hrs)
|
||||
for consistency.
|
||||
|
||||
## Submeters/Power Monitors
|
||||
### Submeters/Power Monitors
|
||||
|
||||
> Name = "Power Monitor"
|
||||
|
||||
See [[switchgear#SPD's/TVSS's]]
|
||||
|
||||
## Panelboards
|
||||
### Switchboards
|
||||
|
||||
> Name = "Switchboard - 2000A, 4-Section"
|
||||
|
||||
### Panelboards
|
||||
|
||||
> Name = "Panelboard - 600A, 2-Section"
|
||||
|
||||
`DISTRIBUTION`/`DIST PANELS & UNIT LOAD CENTERS`/...
|
||||
|
||||
## Disconnects and Enclosed Circuit Breakers
|
||||
### Disconnects and Enclosed Circuit Breakers
|
||||
|
||||
`COMMON ASSEMBLIES`/`DISTRIBUTION`/`MANUAL DISCONNECTS`/...
|
||||
|
||||
## Generators
|
||||
### Generators
|
||||
|
||||
> Name = "Generator - 250kW, Diesel"
|
||||
|
||||
Add `DISTRIBUTION FITTINGS`/`GENERATOR SET UP`.
|
||||
|
||||
## Generator Connection Cabinets
|
||||
### Generator Connection Cabinets
|
||||
|
||||
> Name = "GCC - 200A"
|
||||
|
||||
Use a Distribution Panel of equal amps.
|
||||
Or a transfer switch.
|
||||
|
||||
## Transfer Switches
|
||||
### Transfer Switches
|
||||
|
||||
> "300A ATS"
|
||||
> Name = "Transfer Switch - 400A"
|
||||
|
||||
### Transfer Switches 1200A+
|
||||
#### Transfer Switches 1200A+
|
||||
|
||||
Use 1200A and add an additional `TRANSFER SWITCH` item
|
||||
to make up the remaining amps.
|
||||
|
||||
## Meter Centers
|
||||
### Meter Centers
|
||||
|
||||
> Name = "Meter Center - 800A, 16-Can"
|
||||
|
||||
`SWITCHGEAR & METER CENTERS`/`METER CENTERS`/`... METERING SECTION`
|
||||
|
||||
|
||||