vault backup: 2025-12-10 16:47:02
This commit is contained in:
@@ -55,6 +55,8 @@ and costed a job half a million in profit,
|
||||
what I took away was that we sold high-risk scope
|
||||
without knowing what was required _and without qualification_.
|
||||
|
||||
***
|
||||
|
||||
Others have suggested creating new assemblies grouped by manufacturer,
|
||||
which I'm not a fan of.
|
||||
While it's true that similar implementations
|
||||
|
||||
+2
-2
@@ -77,9 +77,9 @@ then quickly release the first, letting the second ring.
|
||||
}
|
||||
```
|
||||
|
||||
It is possible to add "H" and "Po." markers,
|
||||
It is _possible_ to add "H" and "Po." markers,
|
||||
but the syntax is ugly.
|
||||
They are not ubiquitous anyway.
|
||||
They are not ubiquitous or especially helpful anyway.
|
||||
|
||||
### String Bending
|
||||
|
||||
|
||||
+3
-23
@@ -1,34 +1,14 @@
|
||||
---
|
||||
id:
|
||||
aliases: []
|
||||
title: Conduit Sizing
|
||||
tags:
|
||||
- authorship/original
|
||||
- destiny/fleeting
|
||||
- status/incomplete
|
||||
- topic/construction/electrical
|
||||
- type/encyclopedia
|
||||
- authorship/original
|
||||
title: Conductor Sizing
|
||||
---
|
||||
# Conduit Sizing
|
||||
|
||||
Table 1 Percent of Cross Section of Conduit and Tubing for Conductors and Cables
|
||||
|
||||
| Number of Conductors and/or Cables | Cross-Sectional Area (%) |
|
||||
| ---------------------------------- | ------------------------ |
|
||||
| 1 | 53 |
|
||||
| 2 | 31 |
|
||||
| Over 2 | 40 |
|
||||
|
||||
> [!info] Informational Note No. 1:
|
||||
> Table 1 is based on common conditions of proper cabling and alignment of conductors
|
||||
> where the length of the pull and the number of bends are within reasonable limits.
|
||||
> It should be recognized that, for certain conditions,
|
||||
> a larger size conduit or a lesser conduit fill should be considered.
|
||||
|
||||
> [!info] Informational Note No. 2:
|
||||
> When pulling three conductors or cables into a raceway,
|
||||
> if the ratio of the raceway (inside diameter)
|
||||
> to the conductor or cable (outside diameter)
|
||||
> is between 2.8 and 3.2, jamming can occur.
|
||||
> While jamming can occur when pulling four or more conductors or cables into a raceway,
|
||||
> the probability is very low.
|
||||
![[nfpa-70_ch09#Table 1 Percent of Cross Section of Conduit and Tubing for Conductors and Cables|Table 1 Percent of Cross Section of Conduit and Tubing for Conductors and Cables]]
|
||||
|
||||
@@ -0,0 +1,36 @@
|
||||
---
|
||||
id:
|
||||
aliases:
|
||||
- nec-ch9
|
||||
title: Chapter 9 Tables
|
||||
tags:
|
||||
- authorship/other
|
||||
- destiny/permanent
|
||||
- exclude-from-word-count
|
||||
- status/incomplete
|
||||
- topic/construction/electrical
|
||||
- type/media/reference
|
||||
---
|
||||
# Chapter 9 Tables
|
||||
|
||||
## Table 1 Percent of Cross Section of Conduit and Tubing for Conductors and Cables
|
||||
|
||||
| Number of Conductors and/or Cables | Cross-Sectional Area (%) |
|
||||
| ---------------------------------- | ------------------------ |
|
||||
| 1 | 53 |
|
||||
| 2 | 31 |
|
||||
| Over 2 | 40 |
|
||||
|
||||
> [!info] Informational Note No. 1:
|
||||
> Table 1 is based on common conditions of proper cabling and alignment of conductors
|
||||
> where the length of the pull and the number of bends are within reasonable limits.
|
||||
> It should be recognized that, for certain conditions,
|
||||
> a larger size conduit or a lesser conduit fill should be considered.
|
||||
|
||||
> [!info] Informational Note No. 2:
|
||||
> When pulling three conductors or cables into a raceway,
|
||||
> if the ratio of the raceway (inside diameter)
|
||||
> to the conductor or cable (outside diameter)
|
||||
> is between 2.8 and 3.2, jamming can occur.
|
||||
> While jamming can occur when pulling four or more conductors or cables into a raceway,
|
||||
> the probability is very low.
|
||||
@@ -195,7 +195,9 @@ title: "NFPA 70: National Electric Code"
|
||||
* [[nfpa-70_830|830 Network-Powered Broadband Communications Systems]]
|
||||
* [[nfpa-70_840|840 Premises-Powered Broadband Communications Systems]]
|
||||
|
||||
## Chapter 9 Tables
|
||||
***
|
||||
|
||||
* [[nfpa-70_ch09|Chapter 9 Tables]]
|
||||
|
||||
* [[nfpa-70_anx-a|Annex A: Product Safety Standards]]
|
||||
* [[nfpa-70_anx-b|Annex B: Application Information for Ampacity Calculation]]
|
||||
|
||||
Reference in New Issue
Block a user