vault backup: 2025-11-11 12:22:56

This commit is contained in:
2025-11-11 12:22:56 -05:00
parent 88b9c3b9b1
commit a07bc6c202
11 changed files with 188 additions and 83 deletions
+21 -19
View File
@@ -19,11 +19,11 @@ for use in [[fixtures-takeoff]].
### Format
```regex
<phase-abbr> - <assembly>(\: <subtype>)?( - <fixture-labor>)? \(<wiring-method>\)( <wm-descriptor>)* <branch-length>ft
<phase-abbr> - <assembly>(\: <assembly-subtype>)?( = <fixture-labor>)? <wiring-method> <branch-length>ft
```
> [!example]
> `A - Surface: Pendant - 2.0hrs (MC) LV 20ft`
> `A - Surface: Pendant = 2.0hrs - #12 MC+LV 20ft`
## Order
@@ -67,7 +67,7 @@ Use empty designations to separate phases.
| Exterior Amenity | 50ft |
| Units | 20ft |
| Undercabinet Fixtures | 10ft |
| Stairwells | ? |
| Stairwells | 20ft |
| Kitchen | ? |
Reduce as appropriate.
@@ -89,26 +89,24 @@ Reduce as appropriate.
Use ENT assemblies unless forbidden by spec.
`FIXTURE ACCESSORIES`/`PVC/ENT ASSEMBLIES`/`GARAGE FIXTURE ENT W/#10 - STEEL OCT RING`
`FIXTURE ACCESSORIES`/`PVC/ENT ASSEMBLIES`/`GARAGE FIXTURE W/T ROD ENT W/#10 - STEEL OCT RING`
Use threaded rod assemblies in I-beam/precast garages.
| Case | Assembly Path (`FIXTURE ACCESSORIES`/`PVC/ENT ASSEMBLIES`/...) |
| ----------------- | -------------------------------------------------------------- |
| Conventional Slab | .../`GARAGE FIXTURE ENT W/#10 - STEEL OCT RING` |
| Precast/I-Beam | .../`GARAGE FIXTURE W/T ROD ENT W/#10 - STEEL OCT RING` |
If PVC is required, use following assemblies:
| Case | Assembly Path |
| ------- | ------------------------------------------------------------------------------------------------ |
| Ceiling | `FIXTURE ACCESSORIES`/`PVC/ENT ASSEMBLIES`/`... - SLAB BOX / 45 DEG STUBBY` |
| Wall | `FIXTURE ACCESSORIES`/`PVC/ENT ASSEMBLIES`/`... - STL BOX & TILE RING / 45 DEG STUBBY/ ENT DROP` |
| Case | Assembly Path (`FIXTURE ACCESSORIES`/`PVC/ENT ASSEMBLIES`/...) |
| ------- | -------------------------------------------------------------- |
| Ceiling | .../`... - SLAB BOX / 45 DEG STUBBY` |
| Wall | .../`... - STL BOX & TILE RING / 45 DEG STUBBY/ ENT DROP` |
### Homeruns
> * `System` = "EL - Electrical"
> `COMMON ASSEMBLIES`/`Device Homeruns in Slab/Deck`
Use 1 Homerun for every 3 circuits in Garage
Use assembly `COMMON ASSEMBLIES`/`Device Homeruns in Slab/Deck`
Use 1 homerun for every 3 circuits in Garage
## Surface Mount
@@ -207,6 +205,10 @@ round up to the nearest 5ft
| MC Cable | `MC ASSEMBLIES`/`FAN RATED OCT BOX W/ BAR HNGR - ...` |
| PVC | `PVC/ENT ASSEMBLIES`/`... - SLAB BOX / 45 DEG STUBBY` |
## Guardrail Fixtures
`FIXTURE ACCESSORIES`/`COURTYARDS & LANDSCAPE`/`ALUM BOX W/ FLEX FIX, 3/4" CONDUIT - PVC40 - ...`
## Stairwells & Elevators
`PVC/ENT ASSEMBLIES`/`... - SLAB BOX / 45 DEG STUBBY`
@@ -217,10 +219,10 @@ round up to the nearest 5ft
Length and Labor will be more than a normal fixture in BOH/Amenity
| Fixture Type | Labor (hrs) |
| ------------ | ----------------------------------- |
| Non-Linear | 2 |
| Linear | [See tape lighting](#Tape Lighting) |
| Fixture Type | Labor |
| ------------ | ---------------------- |
| Non-Linear | 2hrs |
| Linear | See [[#Tape Lighting]] |
> 1. `3/4" PVC W/ 3#10 - STL BOX & TILE RING / 45 DEG STUBBY/ ENT DROP`
> * `Length per Unit` = Distance to panel