## Info
### Fire Command Center (FCC)
> [!info] Also Known As
> Emergency Command Center (ECC)
> Fire Alarm Command Center (FACC)
> Fire Alarm Command Room (FACR)
## Sequence
### 1. Preparation
@@ -26,19 +33,24 @@ tags:
### 2. Takeoff
#### Fire Command Center
#### Backbone
Put all backbone takeoff in the `Area` of the Fire Command Center.
Include [[sleeving]] as necessary.
##### Fire Command Center
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`HEAD END EQUIP`/`... HEAD END`
#### Generator Room
##### Generator Room
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`GENERATOR ROOM ...`
#### Fire Pump Room
##### Fire Pump Room
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`FIRE PUMP ROOM ...`
#### FACR to Elevator Shafts
##### FACR to Elevator Shafts
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`ELEV SHAFT ...`
@@ -57,7 +69,7 @@ Input adder length to reach the bottom of the pit
| | |
```
#### FACR to Elevator Control Rooms
##### FACR to Elevator Control Rooms
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`ELEV CONTROL ROOM ...`
@@ -67,7 +79,7 @@ Input adder length to reach the bottom of the pit
* Use Typicals for the vertical riser. (Ex// 10' per floor)
* Add [[sleeving]] as necessary.
#### FACR to Stairwells
##### FACR to Stairwells
This is for the Flow/Tamper modules in the stairwells
@@ -75,7 +87,7 @@ This is for the Flow/Tamper modules in the stairwells
* Measure from the furthest end of FACR to the furthest end of the stairwell to find length
#### Terminal Cabinets
##### Terminal Cabinets
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`TERMINAL CABINET`/`ACE D ACCESSORY CABINET ENCLOSURE (2) 2" ...`
@@ -89,7 +101,7 @@ Vertical:
* Use 10ft Riser in Typical
* Add [[sleeving]] as necessary.
#### Annunciator Panels
##### Annunciator Panels
> [!info] Also Known As
> * Fire Alarm Annunciator (FAA)
@@ -99,25 +111,27 @@ Vertical:
* Measure from the Fire Command Room to FAA or Lobby
#### Smoke Detectors
#### Devices
##### Smoke Detectors
_Design Build:_
Count every stairwell at every level.
#### Pull Stations
##### Pull Stations
_Design Build:_
Count every stairwell at every level
and every exterior exit.
#### Flow-Tamper Switches
##### Flow-Tamper Switches
No free air. if wood frame, take off as EMT.
_Design Build:_
Count every stairwell at every level.
#### Magnetic Door Holders
##### Magnetic Door Holders
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`INDICATING DEVICES WITH WIRE - ...`/`MAGNETIC DOOR HOLDER - ...`
@@ -125,7 +139,7 @@ _Design Build:_
Count every set of double doors.
(Typical of elevator lobbies and corridors)
#### Speaker Strobes
##### Speaker Strobes
_Design Build:_
* Count every 75 ft,
@@ -135,7 +149,7 @@ _Design Build:_
* every elevator lobby,
* and every BOH room on the first floor and garage levels.
#### Firefighter Phone System
##### Firefighter Phone System
* firefighter phone jacks
* fire warden station
@@ -146,7 +160,7 @@ Not related to responder radio.
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`COMMUNICATION DEVICES ...`/`...`
#### Fire Smoke Dampers (FSD's)
##### Fire Smoke Dampers (FSD's)
Take off both FA
@@ -158,4 +172,4 @@ and Electrical
### 3. Review
* Sleeving
* [[sleeving]]