vault backup: 2025-10-08 18:16:15

This commit is contained in:
2025-10-08 18:16:15 -04:00
parent 8e1caca4ad
commit a45d3674e3
6 changed files with 219 additions and 93 deletions
+20 -20
View File
@@ -1,9 +1,29 @@
{ {
"recentFiles": [ "recentFiles": [
{
"basename": "fire-alarm",
"path": "fire-alarm.md"
},
{
"basename": "hvac-calculations",
"path": "hvac-calculations.md"
},
{
"basename": "alternating-current",
"path": "alternating-current.md"
},
{ {
"basename": "conductor-sizing", "basename": "conductor-sizing",
"path": "conductor-sizing.md" "path": "conductor-sizing.md"
}, },
{
"basename": "full-takeoff",
"path": "full-takeoff.md"
},
{
"basename": "electrical",
"path": "electrical.md"
},
{ {
"basename": "README", "basename": "README",
"path": "README.md" "path": "README.md"
@@ -12,14 +32,6 @@
"basename": "stochastic-branch-takeoff", "basename": "stochastic-branch-takeoff",
"path": "stochastic-branch-takeoff.md" "path": "stochastic-branch-takeoff.md"
}, },
{
"basename": "electrical",
"path": "electrical.md"
},
{
"basename": "full-takeoff",
"path": "full-takeoff.md"
},
{ {
"basename": "nfpa-70_314_boxes", "basename": "nfpa-70_314_boxes",
"path": "nfpa-70_314_boxes.md" "path": "nfpa-70_314_boxes.md"
@@ -52,10 +64,6 @@
"basename": "nfpa-70_110_requirements-for-electrical-installations", "basename": "nfpa-70_110_requirements-for-electrical-installations",
"path": "nfpa-70_110_requirements-for-electrical-installations.md" "path": "nfpa-70_110_requirements-for-electrical-installations.md"
}, },
{
"basename": "alternating-current",
"path": "alternating-current.md"
},
{ {
"basename": "construction-estimating", "basename": "construction-estimating",
"path": "construction-estimating.md" "path": "construction-estimating.md"
@@ -191,14 +199,6 @@
{ {
"basename": "functional-labor-factoring", "basename": "functional-labor-factoring",
"path": "functional-labor-factoring.md" "path": "functional-labor-factoring.md"
},
{
"basename": "gold-plating",
"path": "gold-plating.md"
},
{
"basename": "functional-estimating",
"path": "functional-estimating.md"
} }
], ],
"omittedPaths": [], "omittedPaths": [],
+23 -31
View File
@@ -36,27 +36,32 @@ The voltage measured between any line and neutral is called phase voltage.
208Y/120V 208Y/120V
480Y/277V 480Y/277V
In a 3-phase wye connected system,
ignoring the difference in voltage,
is voltage drop calculated differently
between a line to line load and a line to neutral load
### Voltage Systems ### Voltage Systems
120/240V 1-Phase 3-Wire: 120/240V 1-Phase 3-Wire:
- 120V 1-Phase 2-Wire # Line to Neutral * 120V 1-Phase 2-Wire # Line to Neutral
- 240V 1-Phase 2-Wire # Line to Line * 240V 1-Phase 2-Wire # Line to Line
120/208V 3-Phase 4-Wire: 120/208V 3-Phase 4-Wire:
- 120V 1-Phase 2-Wire # Line to Neutral * 120V 1-Phase 2-Wire # Line to Neutral
- 208V 1-Phase 2-Wire # Line to Line * 208V 1-Phase 2-Wire # Line to Line
- 208V 3-Phase 3-Wire # Line to Lines * 208V 3-Phase 3-Wire # Line to Lines
277/480V 3-Phase 4-Wire: 277/480V 3-Phase 4-Wire:
- 277V 1-Phase 2-Wire # Line to Neutral * 277V 1-Phase 2-Wire # Line to Neutral
- 480V 1-Phase 2-Wire # Line to Line * 480V 1-Phase 2-Wire # Line to Line
- 480V 3-Phase 3-Wire # Line to Lines * 480V 3-Phase 3-Wire # Line to Lines
wiring-configurations: wiring-configurations:
- 1-Phase 2-Wire # Line to Neutral or Line to Line * 1-Phase 2-Wire # Line to Neutral or Line to Line
- 1-Phase 3-Wire # Line to Line and Line to Neutral * 1-Phase 3-Wire # Line to Line and Line to Neutral
- 3-Phase 3-Wire # Line to Lines * 3-Phase 3-Wire # Line to Lines
- 3-Phase 4-Wire # Line to Lines and Line to Neutral * 3-Phase 4-Wire # Line to Lines and Line to Neutral
## Active and Reactive Power ## Active and Reactive Power
@@ -65,27 +70,27 @@ and the electromagnetic "inertia" of inductance and capacitance,
inherent of all matter, inherent of all matter,
the power in an AC circuit is divided into two components: the power in an AC circuit is divided into two components:
- **Active Power** * **Active Power**
(abbreviated $P$, measured in watts) (abbreviated $P$, measured in watts)
also known as real power, is power that *does work*. also known as real power, is power that _does work_.
- **Reactive Power** * **Reactive Power**
(abbreviated $Q$, measured in volt-amperes reactive (VAR)) (abbreviated $Q$, measured in volt-amperes reactive (VAR))
transfers no net energy to the load. transfers no net energy to the load.
derived from these components are others: derived from these components are others:
- **Complex Power** * **Complex Power**
(abbreviated $S$, measured in volt-amperes (VA)) (abbreviated $S$, measured in volt-amperes (VA))
is the vector sum of the active and reactive components. is the vector sum of the active and reactive components.
It is "complex" because it exists on the real and imaginary axes It is "complex" because it exists on the real and imaginary axes
of active and reactive power respectively. of active and reactive power respectively.
- **Apparent Power** * **Apparent Power**
(abbreviated $|S|$, measured in volt-amperes (VA)) (abbreviated $|S|$, measured in volt-amperes (VA))
is the magnitude of the complex power vector. is the magnitude of the complex power vector.
- **Power Factor** * **Power Factor**
(abbreviated $\text{PF}$, unitless) (abbreviated $\text{PF}$, unitless)
is the ratio of active power to apparent power. is the ratio of active power to apparent power.
@@ -97,16 +102,3 @@ $$
Capacitance and inductance can both be measured in VAR, Capacitance and inductance can both be measured in VAR,
but their effects cancel each other out rather than add. but their effects cancel each other out rather than add.
## Motors
1hp = 746 watts
full-load current (FLC) / full-load amperes (FLA)
minimum circuit ampacity (MCA)
$$
\text{MCA} = 1.25 \times \text{FLC}
$$
+54 -26
View File
@@ -116,28 +116,45 @@ either for spec requirements or conduit fill considerations.
## Voltage Drop ## Voltage Drop
$$ $$
V_d = I \times R \times L \times M Z = R \cos(\theta) + X \sin(\theta)
$$ $$
where where
* $V_d$ = Voltage Drop in volts ($V$) * $Z$ = Effective impedance
* $I$ = Current in Amperes ($A$) * $R$ = AC resistance
* $R$ = Feeder linear resistance in ohms per foot ($VA^{-1}\text{ft}^{-1}$) * $X$ = Reactance
* $\theta$ = Power factor angle = $\arccos(PF)$
> [!info] 1-Phase, Line to Neutral Voltage Drop
>
> $$
> \Delta V_{LN} = I \times Z \times 2L
> $$
> [!info] 1-Phase, Line to Line Voltage Drop
>
> $$
> \Delta V_{LL} = \sqrt{3} \times I \times Z \times 2L
> $$
> [!info] 3-Phase Voltage Drop
>
> $$
> \Delta V_{3\phi} = \sqrt{3} \times I \times Z \times L
> $$
where
* $\Delta V$ = Voltage drop in volts ($V$)
* $I$ = Current in amperes ($A$)
* $L$ = Length of wire one way in feet ($\text{ft}$) * $L$ = Length of wire one way in feet ($\text{ft}$)
* $M$ = Multiplier
* $2$ for 1-phase
* $\sqrt{3}$ for 3-phase
It is often more useful to know the maximum length It is often more useful to know the maximum length
a certain wiring configuration is suitable for. a certain wiring configuration is suitable for.
$$ $$
L = \frac{ V_d }{ I \times M } \times \frac{1}{R} L = \frac{ \Delta V }{ I \times M } \times \frac{1}{Z}
$$ $$
* $L$ = Max length of wire one way in feet ($\text{ft}$)
* $\frac{ V_d }{ I \times M }$ = Max circuit resistance in ohms ($VA^{-1}$)
> [!info] Ohm's Law > [!info] Ohm's Law
> >
> $$ > $$
@@ -148,6 +165,24 @@ $$
> "Current" is not the OCPD rating, > "Current" is not the OCPD rating,
> but the actual load. > but the actual load.
## Parallel Runs
The equivalent resistance of parallel resistances is given by
$$
\frac{1}{R_{\text{eq}}} = \frac{1}{R_1} + \frac{1}{R_2} + \frac{1}{R_3} + \dots
$$
For $P$ parallel resistances of value $R$
$$
\begin{align*}
\frac{1}{R_{\text{eq}}} &= P \times \left(\frac{1}{R}\right) \\
&= \frac{P}{R} \\
R_{\text{eq}} &= \frac{R}{P}
\end{align*}
$$
## Transformers ## Transformers
$$ $$
@@ -159,21 +194,14 @@ $$
* $V$ = feeder voltage * $V$ = feeder voltage
* $E$ = efficiency * $E$ = efficiency
## Parallel Runs ## Motors
1 electric horsepower = 746 watts
full-load current (FLC) / full-load amperes (FLA)
minimum circuit ampacity (MCA)
$$ $$
\frac{1}{R_{\text{eq}}} = \frac{1}{R_1} + \frac{1}{R_2} + \frac{1}{R_3} + \dots \text{MCA} = 1.25 \times \text{FLC}
$$ $$
where $R_1 = R_n$:
$$
\begin{align*}
\frac{1}{R_{\text{eq}}} &= P \times \left(\frac{1}{R_1}\right) \\
&= \frac{P}{R_1} \\
R_{\text{eq}} &= \frac{R_1}{P}
\end{align*}
$$
where
* $P$ = Number of parallel runs
+3
View File
@@ -52,6 +52,9 @@ Wiring devices and their wall plates are a common target of [[gold-plating]].
Unit condensing units Unit condensing units
Put homeruns on the `Area` of the dwelling unit.
Put connections on the `Area` of the CU.
.../`CONDENSOR HOME RUNS` .../`CONDENSOR HOME RUNS`
.../`CU CONDENSER SLEEVE W/ FLEX - NO HMRN WIRE` .../`CU CONDENSER SLEEVE W/ FLEX - NO HMRN WIRE`
+30 -16
View File
@@ -9,6 +9,13 @@ tags:
## Info ## Info
### Fire Command Center (FCC)
> [!info] Also Known As
> Emergency Command Center (ECC)
> Fire Alarm Command Center (FACC)
> Fire Alarm Command Room (FACR)
## Sequence ## Sequence
### 1. Preparation ### 1. Preparation
@@ -26,19 +33,24 @@ tags:
### 2. Takeoff ### 2. Takeoff
#### Fire Command Center #### Backbone
Put all backbone takeoff in the `Area` of the Fire Command Center.
Include [[sleeving]] as necessary.
##### Fire Command Center
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`HEAD END EQUIP`/`... HEAD END` `COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`HEAD END EQUIP`/`... HEAD END`
#### Generator Room ##### Generator Room
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`GENERATOR ROOM ...` `COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`GENERATOR ROOM ...`
#### Fire Pump Room ##### Fire Pump Room
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`FIRE PUMP ROOM ...` `COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`FIRE PUMP ROOM ...`
#### FACR to Elevator Shafts ##### FACR to Elevator Shafts
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`ELEV SHAFT ...` `COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`ELEV SHAFT ...`
@@ -57,7 +69,7 @@ Input adder length to reach the bottom of the pit
| | | | | |
``` ```
#### FACR to Elevator Control Rooms ##### FACR to Elevator Control Rooms
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`ELEV CONTROL ROOM ...` `COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`ELEV CONTROL ROOM ...`
@@ -67,7 +79,7 @@ Input adder length to reach the bottom of the pit
* Use Typicals for the vertical riser. (Ex// 10' per floor) * Use Typicals for the vertical riser. (Ex// 10' per floor)
* Add [[sleeving]] as necessary. * Add [[sleeving]] as necessary.
#### FACR to Stairwells ##### FACR to Stairwells
This is for the Flow/Tamper modules in the stairwells This is for the Flow/Tamper modules in the stairwells
@@ -75,7 +87,7 @@ This is for the Flow/Tamper modules in the stairwells
* Measure from the furthest end of FACR to the furthest end of the stairwell to find length * Measure from the furthest end of FACR to the furthest end of the stairwell to find length
#### Terminal Cabinets ##### Terminal Cabinets
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`TERMINAL CABINET`/`ACE D ACCESSORY CABINET ENCLOSURE (2) 2" ...` `COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`TERMINAL CABINET`/`ACE D ACCESSORY CABINET ENCLOSURE (2) 2" ...`
@@ -89,7 +101,7 @@ Vertical:
* Use 10ft Riser in Typical * Use 10ft Riser in Typical
* Add [[sleeving]] as necessary. * Add [[sleeving]] as necessary.
#### Annunciator Panels ##### Annunciator Panels
> [!info] Also Known As > [!info] Also Known As
> * Fire Alarm Annunciator (FAA) > * Fire Alarm Annunciator (FAA)
@@ -99,25 +111,27 @@ Vertical:
* Measure from the Fire Command Room to FAA or Lobby * Measure from the Fire Command Room to FAA or Lobby
#### Smoke Detectors #### Devices
##### Smoke Detectors
_Design Build:_ _Design Build:_
Count every stairwell at every level. Count every stairwell at every level.
#### Pull Stations ##### Pull Stations
_Design Build:_ _Design Build:_
Count every stairwell at every level Count every stairwell at every level
and every exterior exit. and every exterior exit.
#### Flow-Tamper Switches ##### Flow-Tamper Switches
No free air. if wood frame, take off as EMT. No free air. if wood frame, take off as EMT.
_Design Build:_ _Design Build:_
Count every stairwell at every level. Count every stairwell at every level.
#### Magnetic Door Holders ##### Magnetic Door Holders
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`INDICATING DEVICES WITH WIRE - ...`/`MAGNETIC DOOR HOLDER - ...` `COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`INDICATING DEVICES WITH WIRE - ...`/`MAGNETIC DOOR HOLDER - ...`
@@ -125,7 +139,7 @@ _Design Build:_
Count every set of double doors. Count every set of double doors.
(Typical of elevator lobbies and corridors) (Typical of elevator lobbies and corridors)
#### Speaker Strobes ##### Speaker Strobes
_Design Build:_ _Design Build:_
* Count every 75 ft, * Count every 75 ft,
@@ -135,7 +149,7 @@ _Design Build:_
* every elevator lobby, * every elevator lobby,
* and every BOH room on the first floor and garage levels. * and every BOH room on the first floor and garage levels.
#### Firefighter Phone System ##### Firefighter Phone System
* firefighter phone jacks * firefighter phone jacks
* fire warden station * fire warden station
@@ -146,7 +160,7 @@ Not related to responder radio.
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`COMMUNICATION DEVICES ...`/`...` `COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`COMMUNICATION DEVICES ...`/`...`
#### Fire Smoke Dampers (FSD's) ##### Fire Smoke Dampers (FSD's)
Take off both FA Take off both FA
@@ -158,4 +172,4 @@ and Electrical
### 3. Review ### 3. Review
* Sleeving * [[sleeving]]
+89
View File
@@ -0,0 +1,89 @@
---
id:
aliases: []
tags: []
---
# HVAC Calculations
## Units
### British Thermal Unit
Unit of heat energy
There are several definitions of the Btu,
HVAC uses the IT definition,
abbreviated Btu<sub>IT</sub>
$$
\begin{align*}
1 \text{Btu}_\text{IT} &= \left( 4.1868 \times 453.59237 \times{\frac{5}{9}} \right) \text{J} \\
&\approx 1055.056 \text{J}
\end{align*}
$$
More common than Btu itself is
thousand British thermal units per hour (MBH),
a unit of power.
$$
\begin{align*}
1 \text{MBH} &= 1000 \text{Btu/hr} \\
&\approx 3.412 \text{W}
\end{align*}
$$
### Ton of Refrigeration (TR or TOR)
Unit of power
> [!info] Also Known As
> * refrigeration ton (RT)
> * ton (refrigeration)
$$
\begin{align*}
1 \text{TR} &= 12000 \text{Btu}_\text{IT}/\text{h} \\
&\approx 3516.853 \text{W}
\end{align*}
$$
### Cubic Feet per Minute (CFM)
Unit of volumetric flow
## Measures
### Airflow
* CFM
External static pressure (ESP)
measured in inches of water
### Heating/Cooling Capacity
* Tons (refrigeration)
* MBH
Entering air temperature (EAT)
Leaving air temperature (LAT)
Mixed air temperature (MAT)
Latent heat
Sensible heat
Sensible -> dry bulb
Latent -> wet bulb
#### ???
OSA EAT (F)
EXH EAT (F)
IN S.L.
OUT ALT.
### Efficiency
* η (eta)