vault backup: 2025-10-09 13:25:21
This commit is contained in:
+64
-64
@@ -1,33 +1,81 @@
|
||||
{
|
||||
"recentFiles": [
|
||||
{
|
||||
"basename": "fire-alarm",
|
||||
"path": "fire-alarm.md"
|
||||
},
|
||||
{
|
||||
"basename": "hvac-calculations",
|
||||
"path": "hvac-calculations.md"
|
||||
},
|
||||
{
|
||||
"basename": "alternating-current",
|
||||
"path": "alternating-current.md"
|
||||
},
|
||||
{
|
||||
"basename": "conductor-sizing",
|
||||
"path": "conductor-sizing.md"
|
||||
"basename": "windows-setup",
|
||||
"path": "windows-setup.md"
|
||||
},
|
||||
{
|
||||
"basename": "full-takeoff",
|
||||
"path": "full-takeoff.md"
|
||||
},
|
||||
{
|
||||
"basename": "electrical",
|
||||
"path": "electrical.md"
|
||||
"basename": "favorite-quotes",
|
||||
"path": "favorite-quotes.md"
|
||||
},
|
||||
{
|
||||
"basename": "README",
|
||||
"path": "README.md"
|
||||
},
|
||||
{
|
||||
"basename": "me",
|
||||
"path": "me.md"
|
||||
},
|
||||
{
|
||||
"basename": "strategy",
|
||||
"path": "strategy.md"
|
||||
},
|
||||
{
|
||||
"basename": "ai-in-estimating",
|
||||
"path": "ai-in-estimating.md"
|
||||
},
|
||||
{
|
||||
"basename": "alternating-current",
|
||||
"path": "alternating-current.md"
|
||||
},
|
||||
{
|
||||
"basename": "area-of-refuge",
|
||||
"path": "area-of-refuge.md"
|
||||
},
|
||||
{
|
||||
"basename": "assembly-objects",
|
||||
"path": "assembly-objects.md"
|
||||
},
|
||||
{
|
||||
"basename": "assembly-philosophy",
|
||||
"path": "assembly-philosophy.md"
|
||||
},
|
||||
{
|
||||
"basename": "automating-estimating-project-creation",
|
||||
"path": "automating-estimating-project-creation.md"
|
||||
},
|
||||
{
|
||||
"basename": "automating-pdf-annotation",
|
||||
"path": "automating-pdf-annotation.md"
|
||||
},
|
||||
{
|
||||
"basename": "conductor-sizing",
|
||||
"path": "conductor-sizing.md"
|
||||
},
|
||||
{
|
||||
"basename": "gold-plating",
|
||||
"path": "gold-plating.md"
|
||||
},
|
||||
{
|
||||
"basename": "accubid-setup",
|
||||
"path": "accubid-setup.md"
|
||||
},
|
||||
{
|
||||
"basename": "hvac-calculations",
|
||||
"path": "hvac-calculations.md"
|
||||
},
|
||||
{
|
||||
"basename": "fire-alarm",
|
||||
"path": "fire-alarm.md"
|
||||
},
|
||||
{
|
||||
"basename": "electrical",
|
||||
"path": "electrical.md"
|
||||
},
|
||||
{
|
||||
"basename": "stochastic-branch-takeoff",
|
||||
"path": "stochastic-branch-takeoff.md"
|
||||
@@ -108,14 +156,6 @@
|
||||
"basename": "this-notebook",
|
||||
"path": "this-notebook.md"
|
||||
},
|
||||
{
|
||||
"basename": "accubid-setup",
|
||||
"path": "accubid-setup.md"
|
||||
},
|
||||
{
|
||||
"basename": "me",
|
||||
"path": "me.md"
|
||||
},
|
||||
{
|
||||
"basename": "material-pricing",
|
||||
"path": "material-pricing.md"
|
||||
@@ -136,14 +176,6 @@
|
||||
"basename": "feeders",
|
||||
"path": "feeders.md"
|
||||
},
|
||||
{
|
||||
"basename": "assembly-objects",
|
||||
"path": "assembly-objects.md"
|
||||
},
|
||||
{
|
||||
"basename": "automating-estimating-project-creation",
|
||||
"path": "automating-estimating-project-creation.md"
|
||||
},
|
||||
{
|
||||
"basename": "project-info",
|
||||
"path": "project-info.md"
|
||||
@@ -164,41 +196,9 @@
|
||||
"basename": "90-day-performance-review",
|
||||
"path": "90-day-performance-review.md"
|
||||
},
|
||||
{
|
||||
"basename": "favorite-quotes",
|
||||
"path": "favorite-quotes.md"
|
||||
},
|
||||
{
|
||||
"basename": "open-problems-in-estimating",
|
||||
"path": "open-problems-in-estimating.md"
|
||||
},
|
||||
{
|
||||
"basename": "location-vs-scope",
|
||||
"path": "Excalidraw/location-vs-scope.md"
|
||||
},
|
||||
{
|
||||
"basename": "company-switch",
|
||||
"path": "company-switch.png"
|
||||
},
|
||||
{
|
||||
"basename": "pathfinding",
|
||||
"path": "pathfinding.md"
|
||||
},
|
||||
{
|
||||
"basename": "gut-feel",
|
||||
"path": "gut-feel.md"
|
||||
},
|
||||
{
|
||||
"basename": "estimating-methodologies",
|
||||
"path": "estimating-methodologies.md"
|
||||
},
|
||||
{
|
||||
"basename": "getting-historical-pricing",
|
||||
"path": "getting-historical-pricing.md"
|
||||
},
|
||||
{
|
||||
"basename": "functional-labor-factoring",
|
||||
"path": "functional-labor-factoring.md"
|
||||
}
|
||||
],
|
||||
"omittedPaths": [],
|
||||
|
||||
@@ -28,3 +28,8 @@ Novel syntax implemented by Obsidian plugins should be avoided.
|
||||
|
||||
All notes are located in the main directory.
|
||||
[[tags]] are used for filtering.
|
||||
|
||||
## Setup from Scratch
|
||||
|
||||
For steps to clone this vault
|
||||
and setup Git see [[windows-setup]].
|
||||
|
||||
+68
-41
@@ -115,6 +115,14 @@ either for spec requirements or conduit fill considerations.
|
||||
|
||||
## Voltage Drop
|
||||
|
||||
> [!info] Ohm's Law
|
||||
>
|
||||
> $$
|
||||
> V = I \times R, \quad R = \frac{ V }{ I }, \quad I = \frac{ V }{ R }
|
||||
> $$
|
||||
|
||||
### Step 1: Effective Impedance $Z$
|
||||
|
||||
$$
|
||||
Z = R \cos(\theta) + X \sin(\theta)
|
||||
$$
|
||||
@@ -125,47 +133,7 @@ where
|
||||
* $X$ = Reactance
|
||||
* $\theta$ = Power factor angle = $\arccos(PF)$
|
||||
|
||||
> [!info] 1-Phase, Line to Neutral Voltage Drop
|
||||
>
|
||||
> $$
|
||||
> \Delta V_{LN} = I \times Z \times 2L
|
||||
> $$
|
||||
|
||||
> [!info] 1-Phase, Line to Line Voltage Drop
|
||||
>
|
||||
> $$
|
||||
> \Delta V_{LL} = \sqrt{3} \times I \times Z \times 2L
|
||||
> $$
|
||||
|
||||
> [!info] 3-Phase Voltage Drop
|
||||
>
|
||||
> $$
|
||||
> \Delta V_{3\phi} = \sqrt{3} \times I \times Z \times L
|
||||
> $$
|
||||
|
||||
where
|
||||
* $\Delta V$ = Voltage drop in volts ($V$)
|
||||
* $I$ = Current in amperes ($A$)
|
||||
* $L$ = Length of wire one way in feet ($\text{ft}$)
|
||||
|
||||
It is often more useful to know the maximum length
|
||||
a certain wiring configuration is suitable for.
|
||||
|
||||
$$
|
||||
L = \frac{ \Delta V }{ I \times M } \times \frac{1}{Z}
|
||||
$$
|
||||
|
||||
> [!info] Ohm's Law
|
||||
>
|
||||
> $$
|
||||
> V = I \times R, \quad R = \frac{ V }{ I }, \quad I = \frac{ V }{ R }
|
||||
> $$
|
||||
|
||||
> [!important]
|
||||
> "Current" is not the OCPD rating,
|
||||
> but the actual load.
|
||||
|
||||
## Parallel Runs
|
||||
#### Parallel Runs
|
||||
|
||||
The equivalent resistance of parallel resistances is given by
|
||||
|
||||
@@ -183,6 +151,65 @@ $$
|
||||
\end{align*}
|
||||
$$
|
||||
|
||||
### Step 2: Voltage Drop
|
||||
|
||||
> [!important]
|
||||
> This section assumes a 3-phase
|
||||
> 208Y/120V or 480Y/277V voltage system
|
||||
|
||||
> [!info] 3-Phase Voltage
|
||||
> $$
|
||||
> V_{LL} = \sqrt{3} \times V_{LN}, \quad V_{LN} = \frac{V_{LL}}{\sqrt{3}}
|
||||
> $$
|
||||
|
||||
3% allowable voltage drop for a 120V line-to-neutral load:
|
||||
|
||||
$$
|
||||
\text{Max} \Delta V = 0.03 \times 120 \text{V}_{LN} = 3.6 \text{V}_{LN}
|
||||
$$
|
||||
|
||||
3% allowable voltage drop for a 208V line-to-line load:
|
||||
|
||||
$$
|
||||
\text{Max} \Delta V = 0.03 \times 208 \text{V}_{LL} = 6.24 \text{V}_{LL}
|
||||
$$
|
||||
|
||||
#### Line to Neutral Loads
|
||||
|
||||
$$
|
||||
\Delta V_{LN} = I \times Z \times 2L
|
||||
$$
|
||||
|
||||
#### Line to Line Loads
|
||||
|
||||
$$
|
||||
\Delta V_{LL} = \sqrt{3} \times \left( I \times Z \times 2L \right)
|
||||
$$
|
||||
|
||||
#### 3-Phase Loads
|
||||
|
||||
$$
|
||||
\Delta V_{3\phi} = \sqrt{3} \times \left( I \times Z \times L \right)
|
||||
$$
|
||||
|
||||
where
|
||||
* $\Delta V$ = Voltage drop in volts ($V$)
|
||||
* $I$ = Current in amperes ($A$)
|
||||
* $L$ = Length of wire one way in feet ($\text{ft}$)
|
||||
|
||||
> [!important]
|
||||
> "Current" is not the OCPD rating,
|
||||
> but the actual load.
|
||||
|
||||
***
|
||||
|
||||
It is often more useful to know the maximum length
|
||||
a certain wiring configuration is suitable for.
|
||||
|
||||
$$
|
||||
L = \frac{ \Delta V }{ I \times M } \times \frac{1}{Z}
|
||||
$$
|
||||
|
||||
## Transformers
|
||||
|
||||
$$
|
||||
|
||||
@@ -65,4 +65,4 @@ Others with as much free time as me tend to spend it exercising.
|
||||
I want to be involved construction estimating for the rest of my working life.
|
||||
Current discourse on the subject is self-similar and sanitized.
|
||||
I'd like to be known as an innovator in [[estimating-philosophy]],
|
||||
and for solving some of its [[open-problems-in-estimating]].
|
||||
and for solving some of its [[open-problems-in-estimating|open problems]].
|
||||
|
||||
@@ -0,0 +1,59 @@
|
||||
# Windows Setup
|
||||
|
||||
## Clone This Vault
|
||||
|
||||
1. Create a [GitHub](https://github.com/)
|
||||
account if you don't have one already.
|
||||
|
||||
2. Install [Git](https://git-scm.com/)
|
||||
|
||||
```
|
||||
winget install Git.Git
|
||||
```
|
||||
|
||||
3. Clone this repo
|
||||
|
||||
```
|
||||
git clone https://github.com/ZaneMeyers/zmVault
|
||||
```
|
||||
|
||||
> [!important]
|
||||
> If you're reading this,
|
||||
> you probably have push access to this repo.
|
||||
> Please do me a favor and don't use it.
|
||||
> It won't be destructive, but it may be annoying.
|
||||
|
||||
If you make unintended changes to this vault:
|
||||
|
||||
```
|
||||
cd zmVault
|
||||
git reset --hard
|
||||
```
|
||||
|
||||
## Setup Obsidian
|
||||
|
||||
1. Download and install [Obsidian](https://obsidian.md/)
|
||||
|
||||
## Create Your Own Vault
|
||||
|
||||
### Create a GitHub Repository
|
||||
|
||||
<!-- TODO: -->
|
||||
|
||||
### Create and Push your Vault
|
||||
|
||||
```
|
||||
mkdir myVault
|
||||
git init
|
||||
git add README.md
|
||||
git commit -m "first commit"
|
||||
git branch -M main
|
||||
git remote add origin https://github.com/ExampleName/myVault.git
|
||||
git push -u origin main
|
||||
```
|
||||
|
||||
### Set Up Your Vault
|
||||
|
||||
Add and enable the Git Community Plugin.
|
||||
|
||||
<!-- TODO: -->
|
||||
Reference in New Issue
Block a user