title: SECTION 1009---ACCESSIBLE MEANS OF EGRESS
|
||||
---
|
||||
# SECTION 1009---ACCESSIBLE MEANS OF EGRESS
|
||||
|
||||
%% TODO %%
|
||||
|
||||
## 1009.6 Areas of refuge.
|
||||
|
||||
Every required area of refuge
|
||||
shall be accessible from the space it serves
|
||||
by an accessible means of egress.
|
||||
|
||||
### 1009.6.5 Two-way communication.
|
||||
|
||||
Areas of refuge shall be provided with a two-way communication system
|
||||
complying with Sections [[#1009.8.1 System requirements.|1009.8.1]]
|
||||
and [[#1009.8.2 Directions.|1009.8.2]].
|
||||
|
||||
%% TODO %%
|
||||
|
||||
## 1009.8 Two-way communication.
|
||||
|
||||
A two-way communication system
|
||||
complying with Sections 1009.8.1 and 1009.8.2
|
||||
shall be provided at the landing serving each elevator or bank of elevators
|
||||
on each accessible floor that is one or more stories above or below
|
||||
the level of exit discharge.
|
||||
|
||||
> [!important] Exceptions:
|
||||
> 1. Two-way communication systems are not required
|
||||
> at the landing serving each elevator or bank of elevators
|
||||
> where the two-way communication system is provided
|
||||
> within areas of refuge in accordance with
|
||||
> [[#1009.6.5 Two-way communication.|Section 1009.6.5.]]
|
||||
>
|
||||
> 2. Two-way communication systems are not required
|
||||
> on floors provided with ramps
|
||||
> conforming to the provisions of Section 1012.
|
||||
>
|
||||
> 3. Two-way communication systems are not required
|
||||
> at the landings serving only service elevators
|
||||
> that are not designated as part of the accessible means of egress
|
||||
> or serve as part of the required accessible route into a facility.
|
||||
>
|
||||
> 4. Two-way communication systems are not required
|
||||
> at the landings serving only freight elevators.
|
||||
>
|
||||
> 5. Two-way communication systems are not required
|
||||
> at the landing serving a private residence elevator.
|
||||
>
|
||||
> 6. Two-way communication systems are not required
|
||||
> in Group I-2 or I-3 facilities.
|
||||
|
||||
### 1009.8.1 System requirements.
|
||||
|
||||
Two-way communication systems shall provide communication
|
||||
between each required location and the fire command center
|
||||
or a central control point location approved by the fire department.
|
||||
Where the central control point is not a constantly attended location,
|
||||
the two-way communication system
|
||||
shall have timed, automatic telephone dial-out capability
|
||||
that provides two-way communication
|
||||
with an approved supervising station or emergency services.
|
||||
The two-way communication system
|
||||
shall include both audible and visible signals.
|
||||
Systems shall be listed in accordance with UL 2525
|
||||
and installed in accordance with NFPA 72.
|
||||
|
||||
### 1009.8.2 Directions.
|
||||
|
||||
Directions for the use of the two-way communication system,
|
||||
instructions for summoning assistance
|
||||
via the two-way communication system
|
||||
and written identification of the location
|
||||
shall be posted adjacent to the two-way communication system.
|
||||
Signage shall comply with the ICC A117.1 requirements for visual characters.
|
||||
|
||||