## Mechanical Connection Selection
|
||||
|
||||
Relevant to [[electrical-takeoff]],
|
||||
sourced from Joel Jansen's OneNote Takeoff Notes "Mechanical Connections".
|
||||
|
||||
Ben says he has never used any PVC assembly except .../`PVC - ...`.
|
||||
|
||||
### NM Connections
|
||||
|
||||
* .../`NM CABLE ASSEMBLIES`
|
||||
|
||||
Type III, IV, and V construction.
|
||||
Usually only 6 AWG and smaller;
|
||||
EMT is expected to be cheaper for larger sizes.
|
||||
|
||||
### MC Connections
|
||||
|
||||
* .../`MC CABLE ASSEMBLIES`
|
||||
|
||||
Type I and II construction.
|
||||
|
||||
> [!quote] Paraphrased from Source
|
||||
> Usually only short runs,
|
||||
> otherwise use PVC if possible.
|
||||
|
||||
> [!important]
|
||||
> Note that MC cable may be forbidden for this application.
|
||||
> > [!quote] Hampton Roads Navy UH - Newport News, Project Specifications
|
||||
> > MC cable shall not be allowed for wiring to mechanical equipment
|
||||
> > except for within the dwelling units.
|
||||
|
||||
### EMT Connections
|
||||
|
||||
* .../`EMT SS - ...`
|
||||
* .../`EMT COMP - ...`
|
||||
|
||||
May be preferred for equipment in the same electrical room
|
||||
as the panel feeding it,
|
||||
otherwise treat as last resort,
|
||||
preferring MC or PVC.
|
||||
|
||||
### PVC Connections
|
||||
|
||||
* .../`PVC - ...`
|
||||
|
||||
Use where equipment disconnect is not integral.
|
||||
|
||||
* .../`PVC - ... - PVC CEILING BOX`
|
||||
|
||||
J-box in the ceiling for mechanical connections,
|
||||
or where a motor-rated switch is shown.
|
||||
|
||||
* .../`PVC - ... - STL BOX & EXT RING`
|
||||
|
||||
Use for equipment powered from a wall mount j-box
|
||||
|
||||
* .../`PVC - ... - EMT DROP`
|
||||
|
||||
> Assembly Note: Does not include j-box
|
||||
|
||||
Use in lieu of .../`PVC - ...`
|
||||
where drop would be exposed
|
||||
if PVC is not permitted to be exposed.
|
||||
|
||||
> Also use for J-Boxes for Heaters.
|
||||
|
||||
> [!example]
|
||||
> directional unit heater shown with connection to a flush wall mount j-box
|
||||
|
||||
* .../`PVC - ... - EMT RISE`
|
||||
|
||||
> Assembly Note: Does not include j-box
|
||||
|
||||
> Use if panels are located on level below panel.
|
||||
> EMT covers vertical transition for exposed conduit
|
||||
|
||||
* .../`PVC - MECH CONNECTION - SGL REC`
|
||||
|
||||
* .../`PVC - STL BOX W/ EXT RING & COVER`
|
||||
|
||||
> For garage heaters, no labor/power term
|
||||