vault backup: 2026-02-04 17:41:43

This commit is contained in:
2026-02-04 17:41:43 -05:00
parent 6bfae1f3ca
commit f37b555f4b
8 changed files with 109 additions and 7 deletions
+1 -1
View File
@@ -148,7 +148,7 @@
"enabled": true, "enabled": true,
"single-quote-enabled": true, "single-quote-enabled": true,
"single-quote-style": "''", "single-quote-style": "''",
"double-quote-enabled": true, "double-quote-enabled": false,
"double-quote-style": "\"\"" "double-quote-style": "\"\""
}, },
"remove-consecutive-list-markers": { "remove-consecutive-list-markers": {
+4 -4
View File
@@ -221,9 +221,9 @@
"clearSelectionAfterAutoPaste": true, "clearSelectionAfterAutoPaste": true,
"respectCursorPositionWhenAutoPaste": true, "respectCursorPositionWhenAutoPaste": true,
"blankLineAboveAppendedContent": true, "blankLineAboveAppendedContent": true,
"autoCopy": false, "autoCopy": true,
"autoFocus": false, "autoFocus": false,
"autoPaste": false, "autoPaste": true,
"autoFocusTarget": "last-active-and-open-then-last-paste", "autoFocusTarget": "last-active-and-open-then-last-paste",
"autoPasteTarget": "last-active-and-open-then-last-paste", "autoPasteTarget": "last-active-and-open-then-last-paste",
"openAutoFocusTargetIfNotOpened": true, "openAutoFocusTargetIfNotOpened": true,
@@ -234,11 +234,11 @@
"executeCommandWhenTargetNotIdentified": true, "executeCommandWhenTargetNotIdentified": true,
"commandToExecuteWhenTargetNotIdentified": "switcher:open", "commandToExecuteWhenTargetNotIdentified": "switcher:open",
"autoPasteTargetDialogTimeoutSec": 20, "autoPasteTargetDialogTimeoutSec": 20,
"autoCopyToggleRibbonIcon": true, "autoCopyToggleRibbonIcon": false,
"autoCopyIconName": "highlighter", "autoCopyIconName": "highlighter",
"autoFocusToggleRibbonIcon": true, "autoFocusToggleRibbonIcon": true,
"autoFocusIconName": "zap", "autoFocusIconName": "zap",
"autoPasteToggleRibbonIcon": true, "autoPasteToggleRibbonIcon": false,
"autoPasteIconName": "clipboard-paste", "autoPasteIconName": "clipboard-paste",
"viewSyncFollowPageNumber": true, "viewSyncFollowPageNumber": true,
"viewSyncPageDebounceInterval": 0.3, "viewSyncPageDebounceInterval": 0.3,
+72
View File
@@ -89,3 +89,75 @@ incentivize problematic (hare-hunting) behavior.
Has such behavior been observed, Has such behavior been observed,
or has chief strategy been organization-aligned or has chief strategy been organization-aligned
in spite of the incentive? in spite of the incentive?
## 2025-02-04
### T-Shirt Sizing
"T-shirt sizing" or "T-shirt size estimation"
is a method of project estimation
characterized by the use of T-shirt sizes
representing project scale buckets.
> [!example]
> * **XS (1-2 days):** Simple UI changes or minor bug fixes
>
> Example: "Update button color on checkout page"
>
> * **S (2-3 days):** Feature enhancements with minimal complexity
>
> Example: "Add product sorting by price"
>
> * **M (5-7 days):** Features requiring moderate integration
>
> Example: "Implement basic search filters"
>
> * **L (8-10 days):** Complex features affecting multiple components
>
> Example: "Create shopping cart functionality"
>
> * **XL (2+ weeks):** Major features requiring breaking down
>
> Example: "Implement payment gateway integration"
>
> --- [T-Shirt Sizing in Agile --- Project Management Pathways](https://www.projectmanagementpathways.com/project-management-articles/tshirt-sizing-in-agile-projects)
The buckets chosen should be wide enough
that scale can be confidently estimated
after minimal investigation.
## 2025-02-04 13:42
[[fire-alarm-takeoff]]
> [!quote] Art Baldwin 2026-02-04 (pp.)
> Fire, smoke, and combination fire/smoke dampers
> may require 120V power, and thus electrical takeoff,
> or only 24V, in which case mechanical will own the scope.
> Assuming 120V is a budget-conservative estimating convenience,
> which is generally considered acceptable
> in lieu of determining specified requirements,
> but further investigation may be expected
> if more than a few per floor are shown.
## 2025-02-04 17:02
While observing takeoff for
[[electrical-takeoff#Unit Condensing Units|unit condensing units]],
the project engineer expressed confusion
at the process of calculating average horizontal length,
expressing that it was more complicated than they expected
considering takeoff procedure for similar processes.
The PE asked why we would not simply use the maximum
so that we would not risk having too little overall.
Their expectation surprised me,
since it is intuitive to me
that there must be some limit to the logic of "covering it"
since it is always within our power to add contingency,
and especially because, if anything,
I feel that our procedures tend towards
the upper end of reasonable ECI.
(see [[value-of-information.jpg]])
My response was not well formulated.
+14
View File
@@ -0,0 +1,14 @@
---
id:
aliases: []
title: Advanced Tables
tags: []
---
# Advanced Tables
| One | Two | Three |
| ---:| ---:| -----:|
| 1 | -2 | |
| 1 | 3 | |
| -1 | -3 | 0 |
<!-- TBLFM: @>=(@2$3-@3) -->
+1 -1
View File
@@ -71,7 +71,7 @@ classDiagram
pie title Estimating Process pie title Estimating Process
"Estimate Preparation" : 15 "Estimate Preparation" : 15
"Takeoff" : 65 "Takeoff" : 65
"Estension & Review" : 10 "Extension & Review" : 10
"Bid Summary" : 10 "Bid Summary" : 10
``` ```
+11
View File
@@ -64,6 +64,13 @@ per [[fire-resistive-wiring-methods-takeoff]].
#### Unit Condensing Units #### Unit Condensing Units
| Level | Horizontal | Vertical | Length | Count |
|:-------- | ----------:| --------:| ------:| -----:|
| Level 01 | 150 | 40 | 190 | |
| Level 02 | 150 | 30 | 180 | |
| Level 03 | 150 | 20 | 170 | |
| Level 04 | 150 | 10 | 160 | |
Put homeruns on the `Area` of the dwelling unit. Put homeruns on the `Area` of the dwelling unit.
Put connections on the `Area` of the CU. Put connections on the `Area` of the CU.
@@ -102,3 +109,7 @@ Max 20 disconnects per rack
Takeoff: `COMMON ASSEMBLIES`/`MISC ASSEMBLIES`/`TRASH CHUTE RISER CIRCUIT...` Takeoff: `COMMON ASSEMBLIES`/`MISC ASSEMBLIES`/`TRASH CHUTE RISER CIRCUIT...`
* **Length** = average floor to floor height * **Length** = average floor to floor height
### Fire/Smoke Dampers
[[fire-alarm-takeoff#Fire/Smoke Dampers (FSD's)]]
+6 -1
View File
@@ -191,7 +191,12 @@ _Design Build (alternative method):_
* 15ft from end of corridor, * 15ft from end of corridor,
* then every 50ft * then every 50ft
## Fire Smoke Dampers (FSD's) ## Fire/Smoke Dampers (FSD's)
> [!info]
> Refers to fire, smoke, and combination fire/smoke dampers.
In [[pdi-building-types#High Rise|high rise construction]], In [[pdi-building-types#High Rise|high rise construction]],
usually found on every level with units. usually found on every level with units.