vault backup: 2026-01-12 11:18:59

This commit is contained in:
2026-01-12 11:18:59 -05:00
parent 76479bcedd
commit f811d9ac91
42 changed files with 169 additions and 119 deletions
+7 -1
View File
@@ -1,7 +1,7 @@
--- ---
id: id:
aliases: [] aliases: []
title: "2026-01-08" title: 2026-01-08
tags: tags:
- authorship/original - authorship/original
- destiny/permanent - destiny/permanent
@@ -46,3 +46,9 @@ $$
$10,000 per [[heavy-equipment#Swing Stage Scaffolding|swing stage]] $10,000 per [[heavy-equipment#Swing Stage Scaffolding|swing stage]]
[[temp-power-takeoff]] [[temp-power-takeoff]]
#### Unit Typicals
I asked Joel about using unit typicals as described in
[[2025-12-19#2025-12-19 10:44]].
He stated that would be acceptable.
+1 -2
View File
@@ -104,8 +104,7 @@ Attributed to William of Ockham, 14th-century English philosopher and theologian
> _Entia non sunt multiplicanda praeter necessitatem_ > _Entia non sunt multiplicanda praeter necessitatem_
> ("Entities must not be multiplied beyond necessity") > ("Entities must not be multiplied beyond necessity")
> Of two competing theories, > "Of two competing theories, the simpler explanation is to be preferred."
> the simpler explanation of an entity is to be preferred."
> [!quote] [[klugman-et-al_2019_loss-models#4.2 The Role of Parameters]] > [!quote] [[klugman-et-al_2019_loss-models#4.2 The Role of Parameters]]
> The principle of parsimony states that the simplest model > The principle of parsimony states that the simplest model
+31
View File
@@ -0,0 +1,31 @@
---
id:
aliases: []
title: "2026-01-12"
tags:
- authorship/original
- destiny/permanent
- status/draft
- type/daily
---
# 2026-01-12
## 2026-01-12 10:00
### ECH3 Executed Contract Revision WBS
For Executed Contract Revisions, Bid GP% must be maintained.
In this case a negative variance was added to the buyout budget
in order to compensate for an increase in permit fee coverage.
## 2026-01-12 10:42
### Woodbrook Executed Contract Revision Takeoff Check
#### Unit Dishwasher/Disposal
Drawings show 2 separate duplex receptacles for dishwasher and disposal
Takeoff used `DW & DISPOSAL DUAL CIR - ...`,
which includes only one receptacle.
According to Joel this takeoff is correct for the scenario.
+2 -2
View File
@@ -52,7 +52,7 @@ Upload extracted drawings to LiveCount
> [!important] > [!important]
> The LiveCount project must be created **before** creating the Accubid job. > The LiveCount project must be created **before** creating the Accubid job.
* Create a new Accubid job: * Create a new Accubid job -
Path: "\\EgnyteDrive\Shared\Trimble\Accubid\Bid\{Project Name} - ConEst.es16" Path: "\\EgnyteDrive\Shared\Trimble\Accubid\Bid\{Project Name} - ConEst.es16"
### Add Drawings to Accubid Job ### Add Drawings to Accubid Job
@@ -71,7 +71,7 @@ Replace the `Area`s with those created in [[project-setup#Setup WBS]]
##### Create Unit Typicals ##### Create Unit Typicals
%% TODO: %% `Area` Typicals for each unit type with quantities by level.
##### Create Helper Typicals ##### Create Helper Typicals
+1 -1
View File
@@ -7,7 +7,7 @@ tags:
- topic/estimating - topic/estimating
- topic/math - topic/math
- type/idea - type/idea
- authorship/original - authorship/llm
title: Functional Estimating title: Functional Estimating
--- ---
# Functional Estimating # Functional Estimating
+16 -2
View File
@@ -1,16 +1,19 @@
--- ---
id: id:
aliases: [] aliases: []
title: Unit Takeoff
tags: tags:
- authorship/original - authorship/original
- destiny/permanent - destiny/permanent
- occupational/takeoff - occupational/takeoff
- status/draft - status/draft
- type/guide - type/guide
title: Unit Takeoff
--- ---
# Unit Takeoff # Unit Takeoff
[[project-setup#Create Unit Matrix|Create Unit Matrix]]
[[accubid-setup#Create Unit Typicals|Create Unit Typicals]]
> [!important] > [!important]
> Complete [[pre-takeoff-research]], > Complete [[pre-takeoff-research]],
> including [[wiring-method-selection]] and [[wiring-device-research]], > including [[wiring-method-selection]] and [[wiring-device-research]],
@@ -82,9 +85,18 @@ Used in lieu of individual split systems.
`COMMON ASSEMBLIES`/`UNITS - MC CABLE ASSEMBLIES`/`GENERAL ASSEMBLIES - METAL STUD`/`UNIT MISC ITEMS - MC - ADJUST ACCORDINGLY` `COMMON ASSEMBLIES`/`UNITS - MC CABLE ASSEMBLIES`/`GENERAL ASSEMBLIES - METAL STUD`/`UNIT MISC ITEMS - MC - ADJUST ACCORDINGLY`
## Dishwasher/Disposal Receptacles
> [!quote] Joel Jansen 2026-01-12 in Reference to Woodbrook (pp.)[^1]
> Even when drawings show 2 separate duplex receptacles,
> use `DW & DISPOSAL DUAL CIR - ...`,
> which includes only one receptacle.
[^1]: [[2026-01-12#Unit Diskwasher/Disposal]]
## Islands ## Islands
Use 1 "SLAB / DECK" receptacle for every 2 circuits in the island. Use 1 `SLAB / DECK` receptacle for every 2 circuits in the island.
`COMMON ASSEMBLIES`/`UNITS - MC CABLE ASSEMBLIES`/`... RECEPTACLE TAMPER RESISTANT ...`/`... (METAL STUD) - 20' 3/4" PVC, ENT, 3#12 THHN` `COMMON ASSEMBLIES`/`UNITS - MC CABLE ASSEMBLIES`/`... RECEPTACLE TAMPER RESISTANT ...`/`... (METAL STUD) - 20' 3/4" PVC, ENT, 3#12 THHN`
@@ -109,6 +121,7 @@ from credenza location to behind television location.
### Residential ### Residential
Included in MSDE. Included in MSDE.
### Key ### Key
`COMMON ASSEMBLIES`/`TELECOM SYSTEMS`/`BOH AMENITY ASSEMBLIES`/... `COMMON ASSEMBLIES`/`TELECOM SYSTEMS`/`BOH AMENITY ASSEMBLIES`/...
@@ -120,6 +133,7 @@ Adjust cable length as needed.
### Residential ### Residential
* `System` = "EL - Electrical" * `System` = "EL - Electrical"
#### Smoke Detectors & CO Detectors #### Smoke Detectors & CO Detectors
For smoke detectors and CO detectors where 120V (most common): For smoke detectors and CO detectors where 120V (most common):