vault backup: 2026-01-12 11:18:59
This commit is contained in:
+7
-1
@@ -1,7 +1,7 @@
|
||||
---
|
||||
id:
|
||||
aliases: []
|
||||
title: "2026-01-08"
|
||||
title: 2026-01-08
|
||||
tags:
|
||||
- authorship/original
|
||||
- destiny/permanent
|
||||
@@ -46,3 +46,9 @@ $$
|
||||
$10,000 per [[heavy-equipment#Swing Stage Scaffolding|swing stage]]
|
||||
|
||||
[[temp-power-takeoff]]
|
||||
|
||||
#### Unit Typicals
|
||||
|
||||
I asked Joel about using unit typicals as described in
|
||||
[[2025-12-19#2025-12-19 10:44]].
|
||||
He stated that would be acceptable.
|
||||
|
||||
+1
-2
@@ -104,8 +104,7 @@ Attributed to William of Ockham, 14th-century English philosopher and theologian
|
||||
> _Entia non sunt multiplicanda praeter necessitatem_
|
||||
> ("Entities must not be multiplied beyond necessity")
|
||||
|
||||
> Of two competing theories,
|
||||
> the simpler explanation of an entity is to be preferred."
|
||||
> "Of two competing theories, the simpler explanation is to be preferred."
|
||||
|
||||
> [!quote] [[klugman-et-al_2019_loss-models#4.2 The Role of Parameters]]
|
||||
> The principle of parsimony states that the simplest model
|
||||
|
||||
@@ -0,0 +1,31 @@
|
||||
---
|
||||
id:
|
||||
aliases: []
|
||||
title: "2026-01-12"
|
||||
tags:
|
||||
- authorship/original
|
||||
- destiny/permanent
|
||||
- status/draft
|
||||
- type/daily
|
||||
---
|
||||
# 2026-01-12
|
||||
|
||||
## 2026-01-12 10:00
|
||||
|
||||
### ECH3 Executed Contract Revision WBS
|
||||
|
||||
For Executed Contract Revisions, Bid GP% must be maintained.
|
||||
In this case a negative variance was added to the buyout budget
|
||||
in order to compensate for an increase in permit fee coverage.
|
||||
|
||||
## 2026-01-12 10:42
|
||||
|
||||
### Woodbrook Executed Contract Revision Takeoff Check
|
||||
|
||||
#### Unit Dishwasher/Disposal
|
||||
|
||||
Drawings show 2 separate duplex receptacles for dishwasher and disposal
|
||||
Takeoff used `DW & DISPOSAL DUAL CIR - ...`,
|
||||
which includes only one receptacle.
|
||||
|
||||
According to Joel this takeoff is correct for the scenario.
|
||||
+2
-2
@@ -52,7 +52,7 @@ Upload extracted drawings to LiveCount
|
||||
> [!important]
|
||||
> The LiveCount project must be created **before** creating the Accubid job.
|
||||
|
||||
* Create a new Accubid job:
|
||||
* Create a new Accubid job -
|
||||
Path: "\\EgnyteDrive\Shared\Trimble\Accubid\Bid\{Project Name} - ConEst.es16"
|
||||
|
||||
### Add Drawings to Accubid Job
|
||||
@@ -71,7 +71,7 @@ Replace the `Area`s with those created in [[project-setup#Setup WBS]]
|
||||
|
||||
##### Create Unit Typicals
|
||||
|
||||
%% TODO: %%
|
||||
`Area` Typicals for each unit type with quantities by level.
|
||||
|
||||
##### Create Helper Typicals
|
||||
|
||||
|
||||
@@ -7,7 +7,7 @@ tags:
|
||||
- topic/estimating
|
||||
- topic/math
|
||||
- type/idea
|
||||
- authorship/original
|
||||
- authorship/llm
|
||||
title: Functional Estimating
|
||||
---
|
||||
# Functional Estimating
|
||||
|
||||
+16
-2
@@ -1,16 +1,19 @@
|
||||
---
|
||||
id:
|
||||
aliases: []
|
||||
title: Unit Takeoff
|
||||
tags:
|
||||
- authorship/original
|
||||
- destiny/permanent
|
||||
- occupational/takeoff
|
||||
- status/draft
|
||||
- type/guide
|
||||
title: Unit Takeoff
|
||||
---
|
||||
# Unit Takeoff
|
||||
|
||||
[[project-setup#Create Unit Matrix|Create Unit Matrix]]
|
||||
[[accubid-setup#Create Unit Typicals|Create Unit Typicals]]
|
||||
|
||||
> [!important]
|
||||
> Complete [[pre-takeoff-research]],
|
||||
> including [[wiring-method-selection]] and [[wiring-device-research]],
|
||||
@@ -82,9 +85,18 @@ Used in lieu of individual split systems.
|
||||
|
||||
`COMMON ASSEMBLIES`/`UNITS - MC CABLE ASSEMBLIES`/`GENERAL ASSEMBLIES - METAL STUD`/`UNIT MISC ITEMS - MC - ADJUST ACCORDINGLY`
|
||||
|
||||
## Dishwasher/Disposal Receptacles
|
||||
|
||||
> [!quote] Joel Jansen 2026-01-12 in Reference to Woodbrook (pp.)[^1]
|
||||
> Even when drawings show 2 separate duplex receptacles,
|
||||
> use `DW & DISPOSAL DUAL CIR - ...`,
|
||||
> which includes only one receptacle.
|
||||
|
||||
[^1]: [[2026-01-12#Unit Diskwasher/Disposal]]
|
||||
|
||||
## Islands
|
||||
|
||||
Use 1 "SLAB / DECK" receptacle for every 2 circuits in the island.
|
||||
Use 1 `SLAB / DECK` receptacle for every 2 circuits in the island.
|
||||
|
||||
`COMMON ASSEMBLIES`/`UNITS - MC CABLE ASSEMBLIES`/`... RECEPTACLE TAMPER RESISTANT ...`/`... (METAL STUD) - 20' 3/4" PVC, ENT, 3#12 THHN`
|
||||
|
||||
@@ -109,6 +121,7 @@ from credenza location to behind television location.
|
||||
### Residential
|
||||
|
||||
Included in MSDE.
|
||||
|
||||
### Key
|
||||
|
||||
`COMMON ASSEMBLIES`/`TELECOM SYSTEMS`/`BOH AMENITY ASSEMBLIES`/...
|
||||
@@ -120,6 +133,7 @@ Adjust cable length as needed.
|
||||
### Residential
|
||||
|
||||
* `System` = "EL - Electrical"
|
||||
|
||||
#### Smoke Detectors & CO Detectors
|
||||
|
||||
For smoke detectors and CO detectors where 120V (most common):
|
||||
|
||||
Reference in New Issue
Block a user