id: electrical
|
|
aliases: []
|
|
tags:
|
|
- destiny/permanent
|
|
- occupational/systems/electrical
|
|
- status/draft
|
|
- type/guide
|
|
title: Electrical
|
|
---
|
|
# Electrical
|
|
|
|
## Info
|
|
|
|
### Lighting Control
|
|
|
|
By PDI convention, [[lighting-controls]] are generally "Electrical", not "Lighting".
|
|
|
|
## Sequence
|
|
|
|
### 1. Preparation
|
|
|
|
[[pre-takeoff-research#Wiring Device Selection]]
|
|
|
|
1. Read about the project specifications and construction type
|
|
2. Locate Equipment Schedules
|
|
|
|
### 2. Takeoff
|
|
|
|
1. Takeoff all equipment that is not #12
|
|
2. Go by Drawing in chronological order
|
|
3. Takeoff Enlarged Drawings
|
|
4. Do final checklist in electrical takeoff notes
|
|
|
|
> [!tip]
|
|
> It is sometimes easier to rebuild a designation than to modify it.
|
|
> For designations with existing takeoffs, Right-Click > `Empty Designation`.
|
|
> The build process can then be completed anew.
|
|
|
|
#### Receptacles
|
|
|
|
#### Floor Boxes
|
|
|
|
##### Poke-Thru's
|
|
|
|
#### Mechanical Connections
|
|
|
|
`COMMON ASSEMBLIES`/`MECHANICAL CONNECTIONS ...`/
|
|
|
|
##### Roof Mounted Equipment
|
|
|
|
Unit condensing units
|
|
|
|
Put homeruns on the `Area` of the dwelling unit.
|
|
Put connections on the `Area` of the CU.
|
|
|
|
.../`CONDENSOR HOME RUNS`
|
|
|
|
.../`CU CONDENSER SLEEVE W/ FLEX - NO HMRN WIRE`
|
|
|
|
`NO SLEEVE`:
|
|
Routed through a "doghouse"
|
|
(a large weatherproof opening)
|
|
with several other feeds.
|
|
Used where drilling openings for individual sleeves
|
|
would be impractical.
|
|
|
|
`PVC SLEEVE`, `EMT SLEEVE`:
|
|
Routed up through the roof,
|
|
(optionally through a disconnect)
|
|
with flex to the equipment.
|
|
|
|
Equipment Racks: Max 20 disconnects per rack
|
|
|
|
`DISTRIBUTIION`/`TRAPEZE RACK SUPPORT ...`/`...`
|
|
|
|
##### Trash Chute
|
|
|
|
**Horizontal:**
|
|
* Check if shown on power drawings as mech connection
|
|
* If not, use 100ft length
|
|
|
|
**Vertical (Riser):**
|
|
* Takeoff: `COMMON ASSEMBLIES`/`MISC ASSEMBLIES`/`TRASH CHUTE RISER CIRCUIT...`
|
|
* Uncheck Link 'Enable Livecount'
|
|
* Takeoff in Typical
|
|
* Length = average floor to floor height
|
|
|
|
#### Homeruns
|
|
|
|
##### Lighting
|
|
|
|
Takeoff homeruns in Building breakdowns,
|
|
even serving Amenity spaces.
|
|
|
|
> [!info] Breakdowns
|
|
> * `Area` = "... Building"
|
|
> * `System` = "Building - BOH ..."
|
|
|
|
### 3. Review
|
|
|
|
1. Count Car chargers and location
|