292 lines
8.7 KiB
Markdown
292 lines
8.7 KiB
Markdown
---
|
|
id:
|
|
aliases: []
|
|
tags:
|
|
- authorship/original
|
|
- destiny/permanent
|
|
- occupational/takeoff
|
|
- status/draft
|
|
- type/guide
|
|
title: Fixture Designations
|
|
---
|
|
# Fixture Designations
|
|
|
|
This note details creation of fixture designations
|
|
for use in [[fixtures-takeoff]].
|
|
|
|
[[luminaire-types]]
|
|
|
|
## Naming
|
|
|
|
### Format
|
|
|
|
```regex
|
|
<phase-abbr> - <assembly>(\: <assembly-subtype>)?( = <fixture-labor>)? <wiring-method> <branch-length>ft
|
|
```
|
|
|
|
> [!example]
|
|
> `A - Surface: Pendant = 2.0hrs - #12 MC+LV 20ft`
|
|
|
|
## Order
|
|
|
|
Use empty designations to separate phases.
|
|
|
|
> [!example]
|
|
>
|
|
> ```
|
|
> *** Hotel Units ***
|
|
> HU - Surface = 1.0hrs - #12 MC+LV 20ft
|
|
> HU - Surface = 1.5hrs - #12 MC+LV 20ft
|
|
> HU - Surface: Pendant = 2.0hrs - #12 MC+LV 20ft
|
|
> HU - Surface: J-Box For Future Fixture = 1.0hrs - #12 MC+LV 20ft
|
|
> HU - Recessed = 1.0hrs - #12 MC+LV 20ft
|
|
> *** Condo Units ***
|
|
> CU - Surface: Tape = 1.0hrs - #12 MC+LV 25ft
|
|
> CU - Surface: Wall = 1.0hrs - #12 MC+LV 25ft
|
|
> ```
|
|
|
|
## Fixture Labor
|
|
|
|
| Fixture Type | Labor |
|
|
|:------------ | ----------:|
|
|
| Paddle Fan | 1.5 hr/ea. |
|
|
| Pendant | 1-4 hr/ea. |
|
|
| Tape | 0.5 hr/6ft |
|
|
| Site Poles | 1.5 hr/ea. |
|
|
| Festoon | 2.0 hr/ea. |
|
|
| All Others | 1.0 hr/ea. |
|
|
|
|
## Fixture Branch Length
|
|
|
|
| Case | Standard Length |
|
|
| --------------------- | --------------- |
|
|
| Site/Courtyard | 50ft |
|
|
| Garage | 50ft |
|
|
| BOH | 40ft |
|
|
| Corridors | 40ft |
|
|
| Interior Amenity | 40ft |
|
|
| Office/Retail | 50ft |
|
|
| Exterior Amenity | 50ft |
|
|
| Units | 20ft |
|
|
| Undercabinet Fixtures | 10ft |
|
|
| Stairwells | 20ft |
|
|
| Kitchen | ? |
|
|
|
|
Reduce as appropriate.
|
|
|
|
## Fixture Branch Wire size
|
|
|
|
| Case | Wire Size |
|
|
| -------------- | --------- |
|
|
| Site/Courtyard | #10 |
|
|
| Garage | #10 |
|
|
| NM Cable | #14[^1] |
|
|
| All Others | #12 |
|
|
|
|
[^1]: Minimum #12 in kitchens and bathrooms.
|
|
|
|
## Garage
|
|
|
|
### Fixtures
|
|
|
|
Use ENT assemblies unless forbidden by spec.
|
|
|
|
| Case | Assembly Path (`FIXTURE ACCESSORIES`/`PVC/ENT ASSEMBLIES`/...) |
|
|
| ----------------- | -------------------------------------------------------------- |
|
|
| Conventional Slab | .../`GARAGE FIXTURE ENT W/#10 - STEEL OCT RING` |
|
|
| Precast/I-Beam | .../`GARAGE FIXTURE W/T ROD ENT W/#10 - STEEL OCT RING` |
|
|
|
|
If PVC is required, use following assemblies:
|
|
|
|
| Case | Assembly Path (`FIXTURE ACCESSORIES`/`PVC/ENT ASSEMBLIES`/...) |
|
|
| ------- | -------------------------------------------------------------- |
|
|
| Ceiling | .../`... - SLAB BOX / 45 DEG STUBBY` |
|
|
| Wall | .../`... - STL BOX & TILE RING / 45 DEG STUBBY/ ENT DROP` |
|
|
|
|
### Homeruns
|
|
|
|
> * `System` = "EL - Electrical"
|
|
> `COMMON ASSEMBLIES`/`Device Homeruns in Slab/Deck`
|
|
|
|
Use 1 homerun for every 3 circuits in Garage
|
|
|
|
## Surface Mount
|
|
|
|
> [!info] Surface Mount Fixtures
|
|
> * Wall Mount
|
|
> * Wall Pack
|
|
> * Sconce
|
|
> * Swing Arm
|
|
> * Pendant
|
|
> * Linear
|
|
> * Tape
|
|
> * Track
|
|
|
|
| Wiring Method | Assembly Path |
|
|
| -------------- | ----------------------------------------------------------- |
|
|
| NM Cable | `NM ASSEMBLIES`/`RND BOX BAR HNGR...` |
|
|
| MC Cable | `MC ASSEMBLIES`/`SQ BOX, ROUND P RING & MNTG BRKT...` |
|
|
| PVC in Ceiling | `PVC/ENT ASSEMBLIES`/`... - SLAB BOX / 45 DEG STUBBY` |
|
|
| PVC in Wall | `PVC/ENT ASSEMBLIES`/`3/4" PVC W/ 3#12 - STL BOX/TILE RING` |
|
|
| EMT | `EMT ASSEMBLIES`/`... - SQ BOX & ROUND P RING` |
|
|
|
|
> [!note]
|
|
> Use lighting control cable assemblies in Amenity areas
|
|
|
|
### Tape Lighting
|
|
|
|
Also called "cove" or "strip" lighting,
|
|
however those terms are less specific
|
|
and potentially confusing.
|
|
|
|
Use item `FIXTURE LABOR 1/2HR`
|
|
and change `Fct 1` to match the calculated labor
|
|
(1 hour per 12 feet).
|
|
|
|
> [!note]
|
|
> Tape lighting length is limited by the "max power length" of the model
|
|
> (usually measured in millimeters).
|
|
> Max power length is usually 5000-15000mm (~16-49ft)
|
|
> depending on luminous output and voltage.
|
|
>
|
|
> A reasonable [[heuristics|rule of thumb]] is
|
|
> * _12V strips:_ 5m (16.4ft)
|
|
> * _24V strips:_ 10m (32.8ft)
|
|
|
|
Separate these fixtures by labor, not length
|
|
|
|
```
|
|
*** Back of House ***
|
|
B - Surface: Tape = 0.5hr (01-06ft) - MC #12 40ft
|
|
B - Surface: Tape = 1.0hr (07-12ft) - MC #12 40ft
|
|
_
|
|
*** Interior Amenity ***
|
|
IA - Surface: Tape = 0.5hr (01-06ft) - MC+LV #12 40ft
|
|
IA - Surface: Tape = 1.0hr (07-12ft) - MC+LV #12 40ft
|
|
IA - Surface: Tape = 1.5hr (13-18ft) - MC+LV #12 40ft
|
|
IA - Surface: Tape = 2.0hr (19-24ft) - MC+LV #12 40ft
|
|
IA - Surface: Tape = 2.5hr (25-30ft) - MC+LV #12 40ft
|
|
IA - Surface: Tape = 3.0hr (31-36ft) - MC+LV #12 40ft
|
|
IA - Surface: Tape = 3.5hr (37-42ft) - MC+LV #12 40ft
|
|
IA - Surface: Tape = 4.0hr (43-48ft) - MC+LV #12 40ft
|
|
IA - Surface: Tape = 4.5hr (49-54ft) - MC+LV #12 40ft
|
|
```
|
|
|
|
## Recessed
|
|
|
|
> [!info] Recessed Fixtures
|
|
> * recessed downlight
|
|
> * recessed linear
|
|
> * wall grazer
|
|
> * troffer
|
|
|
|
| Wiring Method | Assembly Path |
|
|
| ------------- | ------------------------------ |
|
|
| NM Cable | `NM ASSEMBLIES`/`HI HAT - ...` |
|
|
| MC Cable | `MC ASSEMBLIES`/`HI HAT - ...` |
|
|
|
|
For crowded puck light areas:
|
|
measure length between fixtures,
|
|
round up to the nearest 5ft
|
|
|
|
> [!note]
|
|
> "HI HAT" refers to a recessed can fixture.
|
|
|
|
## Undercabinet Fixtures
|
|
|
|
| Wiring Method | Assembly Path |
|
|
| ------------- | ------------------------------------- |
|
|
| NM Cable | `NM ASSEMBLIES`/`UNDER CABINET - ...` |
|
|
| MC Cable | `MC ASSEMBLIES`/`UNDER CABINET - ...` |
|
|
|
|
> [!note]
|
|
> Takeoff 2 fixtures if jumping over oven
|
|
|
|
## Paddle Fans
|
|
|
|
| Wiring Method | Assembly Path |
|
|
| ------------- | ----------------------------------------------------- |
|
|
| NM Cable | `NM ASSEMBLIES`/`RND BOX BAR HNGR...` |
|
|
| MC Cable | `MC ASSEMBLIES`/`FAN RATED OCT BOX W/ BAR HNGR - ...` |
|
|
| PVC | `PVC/ENT ASSEMBLIES`/`... - SLAB BOX / 45 DEG STUBBY` |
|
|
|
|
## Guardrail Fixtures
|
|
|
|
`FIXTURE ACCESSORIES`/`COURTYARDS & LANDSCAPE`/`ALUM BOX W/ FLEX FIX, 3/4" CONDUIT - PVC40 - ...`
|
|
|
|
## Stairwells & Elevators
|
|
|
|
`PVC/ENT ASSEMBLIES`/`... - SLAB BOX / 45 DEG STUBBY`
|
|
|
|
## Facade
|
|
|
|
> * `Phase` = "Facade"
|
|
|
|
Length and Labor will be more than a normal fixture in BOH/Amenity
|
|
|
|
| Fixture Type | Labor |
|
|
| ------------ | ---------------------- |
|
|
| Non-Linear | 2hrs |
|
|
| Linear | See [[#Tape Lighting]] |
|
|
|
|
> 1. `3/4" PVC W/ 3#10 - STL BOX & TILE RING / 45 DEG STUBBY/ ENT DROP`
|
|
> * `Length per Unit` = Distance to panel
|
|
|
|
## Porte Cochere (Drive up Area)
|
|
|
|
Create its own breakout in WBS, and phase in Accubid
|
|
|
|
> [!quote]
|
|
> This is not technically exposed or drop ceiling, but still use PVC
|
|
|
|
## Site & Courtyard
|
|
|
|
> [!important]
|
|
> Coordinate with landscape drawings
|
|
|
|
### Breakdowns
|
|
|
|
> * `System` = "FML - Site Fixtures Material & Labor"
|
|
|
|
### Pole Lights
|
|
|
|
> [!info] Takeoff
|
|
> 1. `FIXTURE ACCESSORIES`/`SITE POLE ASSEMBLIES`/...
|
|
|
|
Add subassemblies for stub-outs, pole, base, and grounding as appropriate.
|
|
|
|
### Festoon Lighting
|
|
|
|
> [!info] Also Known As
|
|
> * string lighting
|
|
> * market lighting
|
|
> * catenary lighting
|
|
|
|
> [!info] Takeoff
|
|
> 1. `FIXTURE LABOR`/`FIXTURE LABOR 2HR`
|
|
>
|
|
> 2. `FESTOON & ROOF ASSEMBLIES`/`FESTOON CABLE HANGER & EYE BOLTS - LENGTH`
|
|
> * **Length per Unit** = Light string length
|
|
>
|
|
> 3. `COURTYARDS & LANDSCAPE`/`ALUM BOX W/ FLEX FIX, 3/4" CONDUIT - PVC40 - ...`
|
|
> * **Length per Unit** = Distance to panel + 15ft
|
|
|
|
### Other Fixture Types
|
|
|
|
| Fixture Type | Path (`FIXTURE ACCESSORIES`/`COURTYARDS & LANDSCAPE`/...) |
|
|
| ------------------------------------ | ------------------------------------------------------------------ |
|
|
| Step Light | .../`STEP FIX, 3/4" CONDUIT - PVC40 - ...` |
|
|
| Bollard | .../`BOLLARD, 3/4" CONDUIT - PVC40 - ...`[^2] |
|
|
| Up-light | .../`PERMA POST, 3/4" CONDUIT - PVC40 - ...` |
|
|
| In-grade up-light | .../`3/4" CONDUIT - PVC40, IMC Elbow, ...` |
|
|
| Fixtures built into cabanas/pergolas | .../`ALUM BOX W/ FLEX FIX, 3/4" CONDUIT - PVC40 - ...` |
|
|
| Handrail light | .../`ALUM BOX W/ FLEX FIX, 3/4" CONDUIT - PVC40, IMC ELBOW - ...` |
|
|
|
|
[^2]: If we don't own concrete, delete pre-cast bollard base from assembly
|
|
|
|
## FAA Lighting
|
|
|
|
> [!info] Takeoff
|
|
> 1. `FIXTURE LABOR`/`FIXTURE LABOR 1HR`
|
|
> 2. `FESTOON & ROOF ASSEMBLIES`/`Aircraft Warning, 3/4" Conduit GRC/PVC 2#10, 1#10G`
|