102 lines
2.1 KiB
Markdown
102 lines
2.1 KiB
Markdown
---
|
|
id: electrical
|
|
aliases: []
|
|
title: Electrical Takeoff
|
|
tags:
|
|
- authorship/original
|
|
- destiny/permanent
|
|
- occupational/takeoff
|
|
- status/draft
|
|
- type/guide
|
|
---
|
|
# Electrical Takeoff
|
|
|
|
> [!important]
|
|
> Complete [[pre-takeoff-research]],
|
|
> including [[wiring-method-selection]] and [[wiring-device-research]],
|
|
> before beginning takeoff.
|
|
|
|
> [!tip]
|
|
> Use [[heating-designations]] for uncertain scope.
|
|
|
|
## Garage
|
|
|
|
In conventional slab garages,
|
|
use ENT and PVC as permitted.
|
|
|
|
In precast slab garages, use EMT.
|
|
|
|
## Receptacles
|
|
|
|
## Floor Boxes
|
|
|
|
`COMMON ASSEMBLIES`/`FLOOR BOXES`/...
|
|
|
|
### Poke-Thru's
|
|
|
|
Use suitable floor box assembly,
|
|
delete floor box items,
|
|
add `ITEM DATABASE`/`WIRING & SYSTEM DEVICES`/`FLOOR BOXES & FITTTINGS`/`GENERIC - FLOOR BOXES & ACCESS`/`POKE-THRU W/ DUPLEX RECEPTACLE`
|
|
|
|
## Homeruns
|
|
|
|
### Lighting
|
|
|
|
* `Area` = "XX - Level XX Building"
|
|
* `Phase` = "Building - Back of House (BOH)"
|
|
|
|
Takeoff homeruns in Building breakdowns,
|
|
even where serving Amenity spaces.
|
|
|
|
## Mechanical Connections
|
|
|
|
`COMMON ASSEMBLIES`/`MECHANICAL CONNECTIONS ...`/...
|
|
|
|
### Stair Pressurization Fans
|
|
|
|
Assume branch circuit conductors must be protected
|
|
per [[fire-resistive-wiring-methods-takeoff]].
|
|
|
|
### Roof Mounted Equipment
|
|
|
|
#### Unit Condensing Units
|
|
|
|
Put homeruns on the `Area` of the dwelling unit.
|
|
Put connections on the `Area` of the CU.
|
|
|
|
.../`CONDENSOR HOME RUNS`
|
|
|
|
.../`CU CONDENSER SLEEVE W/ FLEX - NO HMRN WIRE`
|
|
|
|
`NO SLEEVE`:
|
|
Routed through a "doghouse"
|
|
(a large weatherproof opening)
|
|
with several other feeds.
|
|
Used where drilling openings for individual sleeves
|
|
would be impractical.
|
|
|
|
`PVC SLEEVE`, `EMT SLEEVE`:
|
|
Routed up through the roof,
|
|
(optionally through a disconnect)
|
|
with flex to the equipment.
|
|
|
|
#### Equipment Racks
|
|
|
|
Max 20 disconnects per rack
|
|
|
|
`DISTRIBUTIION`/`TRAPEZE RACK SUPPORT ...`/`...`
|
|
|
|
### Trash Chute
|
|
|
|
1. **Horizontal:**
|
|
|
|
`COMMON ASSEMBLIES`/`MECHANICAL CONNECTIONS ...`/...
|
|
* **Length** = Length per drawings, 100ft if not shown.
|
|
|
|
2. **Vertical (Riser):**
|
|
|
|
* `Area` = "Typical - Building All Levels"
|
|
|
|
Takeoff: `COMMON ASSEMBLIES`/`MISC ASSEMBLIES`/`TRASH CHUTE RISER CIRCUIT...`
|
|
* Length = average floor to floor height
|