# Unit Takeoff
|
|
|
|
> [!important]
|
|
> Complete [[pre-takeoff-research]],
|
|
> including [[wiring-method-selection]] and [[wiring-device-research]],
|
|
> before beginning takeoff.
|
|
|
|
> [!info]
|
|
> See [[multi-family-dwellings]].
|
|
|
|
[[pdi-building-types]]
|
|
|
|
> [!tip] Preparing for Unit Takeoff
|
|
> Units generally have very little variation.
|
|
> It is usually best to copy-paste takeoffs
|
|
> rather than re-build them for each unit.
|
|
|
|
1. Kitchen and Bath
|
|
2. General assemblies
|
|
3. Low Voltage
|
|
4. Lighting Fixtures
|
|
5. Lighting Control
|
|
|
|
> [!tip]
|
|
> It may be more efficient and neat to not copy switches,
|
|
> instead keeping the switch assembly list open
|
|
> and creating them new for each unit,
|
|
> since the types required can vary greatly between units.
|
|
|
|
## Load Centers
|
|
|
|
| Rating | Assembly |
|
|
| ------- | ---------------------------------------------------------------------------------- |
|
|
| <= 100A | `DIST PANELS & UNIT LOAD CENTERS`/`UNIT LOAD CENTERS - ...`/`... UNIT LOAD CENTER` |
|
|
| > 100A | `DIST PANELS & UNIT LOAD CENTERS`/`UNIT LOAD CENTERS - ...`/`... BREAKER PNL` |
|
|
|
|
Include terminations per [[switchgear]].
|
|
|
|
## Fixtures
|
|
|
|
[[fixtures-takeoff]]
|
|
|
|
## Shade Control
|
|
|
|
## VTAC Units
|
|
|
|
Used in lieu of individual split systems.
|
|
|
|
## Dedicated Circuit Receptacles
|
|
|
|
> [!quote] Joel Jansen 2025-11-11, pp.
|
|
>
|
|
> For N5-15R/N5-20R receptacles serving fixed equipment such as:
|
|
>
|
|
> * refrigerators
|
|
> * gas ranges
|
|
> * microwaves
|
|
> * clothes washers
|
|
> * hood fans
|
|
>
|
|
> match the receptacle configuration shown on the plans
|
|
> (i.e. simplex to simplex, duplex to duplex).
|
|
|
|
## Air Sealing
|
|
|
|
* LEED Silver
|
|
* Mid-Atlantic jobs
|
|
* "Draft Proof Box"
|
|
|
|
`ITEM DATABASE`/`BOXES & CABINETS`/`BOXES - VAPOR`/`...`
|
|
|
|
`COMMON ASSEMBLIES`/`UNITS - MC CABLE ASSEMBLIES`/`GENERAL ASSEMBLIES - METAL STUD`/`UNIT MISC ITEMS - MC - ADJUST ACCORDINGLY`
|
|
|
|
## Islands
|
|
|
|
Use 1 "SLAB / DECK" receptacle for every 2 circuits in the island.
|
|
|
|
`COMMON ASSEMBLIES`/`UNITS - MC CABLE ASSEMBLIES`/`... RECEPTACLE TAMPER RESISTANT ...`/`... (METAL STUD) - 20' 3/4" PVC, ENT, 3#12 THHN`
|
|
|
|
Use standard MC assemblies for remaining devices.
|
|
|
|
## Bidet Toilets, Whirlpool Baths, etc.
|
|
|
|
`COMMON ASSEMBLIES`/`MECHANICAL CONNECTIONS (UP TO 100A)`/`PVC - LT NM FLEX (CARFLEX)`/`20A 1PH MECH CONN (100') 3/4" PVC 3#12 - CARFLEX`
|
|
|
|
## "High-Lows"
|
|
|
|
Empty in-wall pass through
|
|
from credenza location to behind television location.
|
|
|
|
`COMMON ASSEMBLIES`/`TELECOM SYSTEMS`/`UNIT DATA - TELECOM`/`HIGH-LOW - TV SCOOP 1 1/2" ENT - NO CABLE`
|
|
|
|
> 
|
|
> Eaton 35M2W
|
|
|
|
## Telecom Homeruns
|
|
|
|
### Residential
|
|
|
|
Included in MSDE.
|
|
### Key
|
|
|
|
`COMMON ASSEMBLIES`/`TELECOM SYSTEMS`/`BOH AMENITY ASSEMBLIES`/...
|
|
|
|
Adjust cable length as needed.
|
|
|
|
## Fire Alarm Devices
|
|
|
|
### Residential
|
|
|
|
* `System` = "EL - Electrical"
|
|
#### Smoke Detectors & CO Detectors
|
|
|
|
For smoke detectors and CO detectors where 120V (most common):
|
|
|
|
`COMMON ASSEMBLIES`/`UNITS - MC CABLE ASSEMBLIES`/`GENERAL ASSEMBLIES - METAL STUD`/`UNIT SMOKE DETECTOR W/ CO DETECTOR ...`
|
|
|
|
For ADA units:
|
|
|
|
`COMMON ASSEMBLIES`/`UNITS - MC CABLE ASSEMBLIES`/`GENERAL ASSEMBLIES - METAL STUD`/`UNIT SMOKE DETECTOR / VISUAL SIGNAL ...`
|
|
|
|
#### Additional Signaling Devices
|
|
|
|
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`INDICATING DEVICES WITH WIRE - ...`/`UNIT HORN/STROBE - ...`
|
|
|
|
### Key
|
|
|
|
* `System` = "FA - Fire Alarm"
|
|
|
|
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`... DEVICES WITH WIRE - FREE AIR`
|
|
|
|
[[fire-alarm-takeoff]]
|