124 lines
3.1 KiB
Markdown
124 lines
3.1 KiB
Markdown
---
|
|
tags:
|
|
- topic/construction
|
|
- type/encyclopedia
|
|
title: IBC Construction Types
|
|
---
|
|
# IBC Construction Types
|
|
|
|
[[ibc_s0602|IBC Section 602: Construction Classification]]
|
|
lists 5 major construction types based on fire ratings/materials.
|
|
|
|
> [!info] 5-Over-1 Construction ^5-over-1
|
|
>
|
|
> "5-over-1" construction denotes a building
|
|
> with levels of combustible construction
|
|
> above levels of non-combustible construction.
|
|
>
|
|
> buildings with two non-combustible levels (5-over-2)
|
|
> and Type III upper floors (3-over-1)
|
|
> are also common,
|
|
> though "5-over-1" denotes the general practice.
|
|
|
|
## Type I: Fire Resistive Non-Combustible
|
|
|
|
Building elements are noncombustible[^1]
|
|
|
|
[^1]: Defined as passing the test procedures
|
|
for defining combustibility of elementary materials
|
|
set forth in ASTM E 136
|
|
|
|
* Concrete, masonry, noncombustible steel
|
|
|
|
### Type I-A: Protected Fire-Resistive Non-Combustible
|
|
|
|
Common of [[pdi-building-types#High Rise|high-rise]]
|
|
and [[ibc-occupancy-classifications#Group I Institutional|Group I]] occupancies.
|
|
|
|
* 3hr Exterior Walls
|
|
* 3hr Structural Frame
|
|
* 2hr Floor/Ceiling Assembly
|
|
* 1.5hr Roof Protection
|
|
|
|
### Type I-B: Unprotected Fire-Resistive Non-Combustible
|
|
|
|
Common of [[pdi-building-types#Mid Rise|mid rise]] office
|
|
and [[ibc-occupancy-classifications#Group R Residential|Group R]] occupancies.
|
|
|
|
* 2hr Exterior Walls
|
|
* 2hr Structural Frame
|
|
* 2hr Ceiling/Floor Separation
|
|
* 1hr Ceiling/Roof Assembly
|
|
|
|
## Type II: Non-Combustible
|
|
|
|
Same materials as [[#Type I Fire-Resistive Non-Combustible|Type I]],
|
|
with reduced fire-resistance requirements.
|
|
|
|
Common of [[pdi-building-types#Mid Rise|mid rise]] buildings.
|
|
|
|
### Type II-A: Protected Non-Combustible
|
|
|
|
Common of [[pdi-building-types#High Density|high density]],
|
|
including dormitory buildings.
|
|
|
|
* 1hr Exterior Walls
|
|
* 1hr Structural Frame
|
|
* 1hr Floor/Ceiling/Roof Protection
|
|
|
|
### Type II-B: Unprotected Non-Combustible
|
|
|
|
Common of [[pdi-building-types#Commercial|commercial]].
|
|
|
|
## Type III: Combustible
|
|
|
|
Also known as "ordinary" construction.
|
|
|
|
Exterior walls are of noncombustible materials.
|
|
Interior building elements may be combustible.
|
|
|
|
### Type III-A: Protected Combustible
|
|
|
|
Common of [[pdi-building-types#High Density|high density]].
|
|
|
|
* 2hr Exterior Walls
|
|
* 1hr Structural Frame
|
|
* 1hr Floor/Ceiling/Roof Protection
|
|
|
|
### Type III-B: Unprotected Combustible
|
|
|
|
Common of "warehouse" districts of older cities.
|
|
|
|
* 2hr Exterior Walls
|
|
|
|
## Type IV: Heavy Timber
|
|
|
|
Also known as "mill" construction.
|
|
|
|
Exterior walls are of noncombustible materials.
|
|
Interior building elements are of solid or laminated wooden members
|
|
with a minimum nominal dimension of 8 inches
|
|
without concealed spaces.
|
|
|
|
* 2hr Exterior Walls
|
|
* 1hr Structural Frame or Heavy Timber Heavy Timber Floor/Ceiling/Roof Assemblies
|
|
|
|
## Type V: Wood Frame
|
|
|
|
Construction materials are of any allowed by code,
|
|
combustible or noncombustible.
|
|
|
|
Common of [[pdi-building-types#Garden Style|garden style]] or above podiums
|
|
|
|
### Type V-A: Protected Wood Frame
|
|
|
|
Commonly used in the construction of newer apartment buildings.
|
|
There is no exposed wood visible.
|
|
|
|
* 1hr Exterior Walls
|
|
* 1hr Structural Frame 1hr Floor/Ceiling/Roof
|
|
|
|
### Type V-B: Unprotected Wood Frame
|
|
|
|
Common of single family homes.
|