@@ -31,19 +31,19 @@ Include [[sleeving-takeoff]] as necessary.
### Fire Command Center
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`HEAD END EQUIP`/`... HEAD END`
1. `COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`HEAD END EQUIP`/`... HEAD END`
### Generator Room
`Area` = Same as FACR
1. `Area` = Same as FACR
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`GENERATOR ROOM ...`
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`GENERATOR ROOM ...`
### Fire Pump Room
`Area` = Same as FACR
1. `Area` = Same as FACR
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`FIRE PUMP ROOM ...`
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`FIRE PUMP ROOM ...`
### Elevator Control Rooms
@@ -51,29 +51,23 @@ Include [[sleeving-takeoff]] as necessary.
For each Elevator Control Room (ECR):
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`ELEV CONTROL ROOM ...`
1. `COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`ELEV CONTROL ROOM ...`
* **Count** = 1
* **Count** = 1
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`FACR TO ELEV CONTROL RM ...`
* **Length** = Length measured from the most distant points of the FACR and ECR.
* Input adder length to reach the level of the ECR (Minimum 15ft).
2. `COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`FACR TO ELEV CONTROL RM ...`
* **Length** = Length measured from the most distant points of the FACR and ECR.
* Input adder length to reach the level of the ECR (Minimum 15ft).
### Elevator Shafts
`Area` = Same as FACR
For each elevator shaft:
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`ELEV SHAFT ...`
1. `COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`ELEV SHAFT ...`
* **Count** = 1
* **Count** = 1
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`FACR TO ELEV SHAFT ...`
* **Length** = Length measured from the most distant points of the FACR and elevator shaft.
* Input adder length to reach the level of the shaft (Minimum 15ft).
2. `COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`FACR TO ELEV SHAFT ...`
* **Length** = Length measured from the most distant points of the FACR and elevator shaft.
* Input adder length to reach the level of the shaft (Minimum 15ft).
> [!important] Counting Elevator Shafts
> Adjacent elevators may be in the same or parallel shafts.
@@ -95,10 +89,9 @@ For each elevator shaft:
For each stairwell:
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`FACR TO STAIRWELLS 1" CONDUIT ...`
* **Length** = Length measured from the most distant points of the FACR and stairwell.
* Input adder length to reach the level of the stairwell (Minimum 15ft).
1. `COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`GEN, ELEV, FIRE PUMP & FA ROOM ASSEMBLIES`/`FACR TO STAIRWELLS 1" CONDUIT ...`
* **Length** = Length measured from the most distant points of the FACR and stairwell.
* Input adder length to reach the level of the stairwell (Minimum 15ft).
## Terminal Cabinets
@@ -107,15 +100,19 @@ For each stairwell:
* _Garden Style, High Density:_ (2) 1"C
* _High Rise:_ (2) 2"C
Horizontal:
1. Horizontal:
> * `Area` = Same as FACR
> * **Length** = Length measured from FACR to all electrical rooms
* `Area` = Same as FACR
`... HORIZONTAL RUN`
* **Length** = Length measured from FACR to all electrical rooms
Vertical:
2. Vertical:
> * `Area` = "Typical - Building All Levels"
> * **Length** = 10ft
* `Area` = "Typical - Building All Levels"
`... RISER`
* **Length** = 10ft
## Annunciator Panels
@@ -123,13 +120,13 @@ Vertical:
> * Fire Alarm Annunciator (FAA)
> * Fire Alarm Annunciator Panel (FAAP)
> `COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`ANNUNCIATORS`/`REMOTE SERIAL ANNUNCIATOR ...`
> * **Length** = Length measured from the FACR to FAA or Lobby
1. `COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`ANNUNCIATORS`/`REMOTE SERIAL ANNUNCIATOR ...`
* **Length** = Length measured from the FACR to FAA or Lobby
## Central Monitoring Loop
> [!important]
> Garden Style only.
> Garden Style only.
> Fire Alarm Control Panels from each building will send a signal to a central location.
>
@@ -141,14 +138,14 @@ Vertical:
### Smoke Detectors
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`INITIATING DEVICES WITH WIRE - ...`/`SMOKE DETECTOR W/ BASE - ...`
1. `COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`INITIATING DEVICES WITH WIRE - ...`/`SMOKE DETECTOR W/ BASE - ...`
_Design Build:_
Count every stairwell at every level.
### Pull Stations
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`INITIATING DEVICES WITH WIRE - ...`/`PULL STATION - ...`
1. `COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`INITIATING DEVICES WITH WIRE - ...`/`PULL STATION - ...`
_Design Build:_
Count every stairwell at every level
@@ -163,7 +160,7 @@ Count every stairwell at every level.
### Magnetic Door Holders
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`INDICATING DEVICES WITH WIRE - ...`/`MAGNETIC DOOR HOLDER - ...`
1. `COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`INDICATING DEVICES WITH WIRE - ...`/`MAGNETIC DOOR HOLDER - ...`
_Design Build:_
Count 2 for every set of double doors.
@@ -171,9 +168,9 @@ Count 2 for every set of double doors.
### Horns, Speakers, and Strobes
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`INDICATING DEVICES WITH WIRE - ...`/`INDOOR HORN STROBE - ...`
1. `COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`INDICATING DEVICES WITH WIRE - ...`/`INDOOR HORN STROBE - ...`
_Design Build:_
_Design Build (method 1):_
* Count every 75 ft,
* measure with circles on Bluebeam
* or divide relevant SF area by 4415
@@ -181,29 +178,18 @@ _Design Build:_
* every elevator lobby,
* and every BOH room on the first floor and garage levels.
_Design Build (alt):_
_Design Build (alternative method):_
* 15ft from end of corridor,
* then every 50ft
## Firefighter Phone System
* firefighter phone jacks
* fire warden station
* fire phone cabinet
Communicates directly with FACR.
Not related to responder radio.
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`COMMUNICATION DEVICES ...`/`...`
## Fire Smoke Dampers (FSD's)
For each damper, take off both
`System` = "FA - Fire Alarm"
1. * `System` = "FA - Fire Alarm"
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`INITIATING DEVICES ...`/`ADDRESSABLE OUTPUT RELAY MODULE ...`
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`INITIATING DEVICES ...`/`ADDRESSABLE OUTPUT RELAY MODULE ...`
and `System` = "EL - Electrical"
2. * `System` = "EL - Electrical"
`COMMON ASSEMBLIES`/`MISC ASSEMBLIES`/`FSD ...`
`COMMON ASSEMBLIES`/`MISC ASSEMBLIES`/`FSD ...`