@@ -12,6 +12,22 @@ All control methods are likely to appear in drawings.
> [!info] "Local Control"
> The term "local control only" is sometimes used to indicate no condiseration
> for *any* lighting control beyond standard devices,
> (with dimmers being the triac type)
> (with $Ds being the triac type)
> however, this phrasing is ambiguous and non-universal.
> Confirm with the bid team on what must be included.
## Custom Switch Boxes
For switch combinations not in `COMMON ASSEMBLIES`,
create heating designations based on the most similar.
### Naming
#### Format
```regex
<phase-abbr> - <assembly>(\: <subtype>)?( - <fixture-labor>)? \(<wiring-method>\)( <wm-descriptor>)* <branch-length>ft
```
> [!example]
> `A - Surface: Pendant - 2.0hrs (MC) LV 20ft`
+47 -21
View File
@@ -1,8 +1,34 @@
# Lighting Takeoff
# Lighting Takeoff (Fixtures)
## Fixtures
## Naming
### Fixture Labor
### Format
```regex
<phase-abbr> - <assembly>(\: <subtype>)?( - <fixture-labor>)? \(<wiring-method>\)( <wm-descriptor>)* <branch-length>ft
```
> [!example]
> `A - Surface: Pendant - 2.0hrs (MC) LV 20ft`
### Order
Use empty designations to separate phases.
> [!example]
> ```
> *** Hotel Units ***
> HU - Surface (MC) LV 20ft
> HU - Surface - 1.5hrs (MC) LV 20ft
> HU - Surface: Pendant - 2.0hrs (MC) LV 20ft
> HU - Surface: J-Box For Future Fixture (MC) LV 20ft
> HU - Recessed (MC) LV 20ft
> *** Condo Units ***
> CU - Surface: Tape - 1.0hrs (MC) LV 25ft
> CU - Surface: Wall (MC) LV 25ft
> ```
## Fixture Labor
> | Fixture Type | Labor |
> | ------------ | -------------- |
@@ -15,7 +41,7 @@
>
> [^1]: Determine exact labor from fixture and size.
### Fixture Branch Length
## Fixture Branch Length
> | Case | Standard Length |
> | ------------- | --------------- |
@@ -32,7 +58,7 @@
>
> [^2]: See fixture types below for special cases.
### Fixture Branch Wire size
## Fixture Branch Wire size
> | Case | Wire Size |
> | -------------- | --------- |
@@ -45,9 +71,9 @@
>
> [^2]: Kitchen and bathroom fixtures shall be #12 (NOT #14) on wood frame (NM) projects.
### Garage
## Garage
#### Fixtures
### Fixtures
Use ENT Assembly unless spec requires otherwise.
@@ -61,7 +87,7 @@ If PVC, use following assemblies:
| Ceiling | `PVC/ENT ASSEMBLIES`/`... - SLAB BOX / 45 DEG STUBBY` |
| Wall | `PVC/ENT ASSEMBLIES`/`... - STL BOX & TILE RING / 45 DEG STUBBY/ ENT DROP` |
#### Homeruns
### Homeruns
> `System` = "EL - Electrical"
@@ -69,7 +95,7 @@ Use 1 Homerun for every 3 circuits in Garage
Use assembly `Common Assemblies`/`Device Homeruns in Slab/Deck`
### Surface Mount
## Surface Mount
* Wall Mount (Sconce)
* Pendant
@@ -88,7 +114,7 @@ Use assembly `Common Assemblies`/`Device Homeruns in Slab/Deck`
> [!note]
> Use lighting control cable assemblies in Amenity areas
#### Tape Lighting
### Tape Lighting
Also called "cove" or "strip",
however those terms are less specific
@@ -128,7 +154,7 @@ A - Tape 9.5hr (109-114ft) - MC #12 40ft
A - Tape 10.0hr (115-120ft) - MC #12 40ft
```
### Recessed
## Recessed
* recessed downlight
* recessed linear
@@ -147,7 +173,7 @@ round up to the nearest 5ft
> [!note]
> "HI HAT" refers to a recessed can fixture.
### Undercabinet Fixtures
## Undercabinet Fixtures
| Wiring Method | Assembly Path |
| ------------- | ------------------------------------- |
@@ -159,7 +185,7 @@ round up to the nearest 5ft
Use 10ft #12/2 for MC & NM
### Paddle Fans
## Paddle Fans
| Wiring Method | Assembly Path |
| ------------- | ----------------------------------------------------- |
@@ -167,11 +193,11 @@ Use 10ft #12/2 for MC & NM
| MC Cable | `MC ASSEMBLIES`/`FAN RATED OCT BOX W/ BAR HNGR - ...` |
| PVC | `PVC/ENT ASSEMBLIES`/`... - SLAB BOX / 45 DEG STUBBY` |
### Stairwells & Elevators
## Stairwells & Elevators
`PVC/ENT ASSEMBLIES`/`... - SLAB BOX / 45 DEG STUBBY`
### Facade
## Facade
> `Phase` = "Facade"
@@ -185,24 +211,24 @@ Length and Labor will be more than a normal fixture in BOH/Amenity
> 1. `3/4" PVC W/ 3#10 - STL BOX & TILE RING / 45 DEG STUBBY/ ENT DROP`
> * `Length per Unit` = Distance to panel
### Porte Cochere (Drive up Area)
## Porte Cochere (Drive up Area)
Create its own breakout in WBS, and phase in Accubid
This is not technically exposed or drop ceiling, but still use PVC
### FAA Lighting
## FAA Lighting
> 1. `FIXTURE LABOR`/`FIXTURE LABOR 1HR`
> 2. `FESTOON & ROOF ASSEMBLIES`/`Aircraft Warning, 3/4" Conduit GRC/PVC 2#10, 1#10G`
## Site & Courtyard
# Site & Courtyard
### Breakdowns
## Breakdowns
> `System` = "FML - Site Fixtures Material & Labor"
### Fixture Assemblies
## Fixture Assemblies
> | Fixture Type | Assembly Path |
> | ------------------------------------ | -------------------------------------------------------------------------------- |
@@ -217,7 +243,7 @@ This is not technically exposed or drop ceiling, but still use PVC
>
> [^2]: Per Corwin: Hand rail lights should have a rigid 90 stub up and some flex
#### Festoon Lighting
### Festoon Lighting
AKA "string" or "market" lights