@@ -12,6 +12,22 @@ All control methods are likely to appear in drawings.
|
||||
> [!info] "Local Control"
|
||||
> The term "local control only" is sometimes used to indicate no condiseration
|
||||
> for *any* lighting control beyond standard devices,
|
||||
> (with dimmers being the triac type)
|
||||
> (with $Ds being the triac type)
|
||||
> however, this phrasing is ambiguous and non-universal.
|
||||
> Confirm with the bid team on what must be included.
|
||||
|
||||
## Custom Switch Boxes
|
||||
|
||||
For switch combinations not in `COMMON ASSEMBLIES`,
|
||||
create heating designations based on the most similar.
|
||||
|
||||
### Naming
|
||||
|
||||
#### Format
|
||||
|
||||
```regex
|
||||
<phase-abbr> - <assembly>(\: <subtype>)?( - <fixture-labor>)? \(<wiring-method>\)( <wm-descriptor>)* <branch-length>ft
|
||||
```
|
||||
|
||||
> [!example]
|
||||
> `A - Surface: Pendant - 2.0hrs (MC) LV 20ft`
|
||||
|
||||
@@ -1,8 +1,34 @@
|
||||
# Lighting Takeoff
|
||||
# Lighting Takeoff (Fixtures)
|
||||
|
||||
## Fixtures
|
||||
## Naming
|
||||
|
||||
### Fixture Labor
|
||||
### Format
|
||||
|
||||
```regex
|
||||
<phase-abbr> - <assembly>(\: <subtype>)?( - <fixture-labor>)? \(<wiring-method>\)( <wm-descriptor>)* <branch-length>ft
|
||||
```
|
||||
|
||||
> [!example]
|
||||
> `A - Surface: Pendant - 2.0hrs (MC) LV 20ft`
|
||||
|
||||
### Order
|
||||
|
||||
Use empty designations to separate phases.
|
||||
|
||||
> [!example]
|
||||
> ```
|
||||
> *** Hotel Units ***
|
||||
> HU - Surface (MC) LV 20ft
|
||||
> HU - Surface - 1.5hrs (MC) LV 20ft
|
||||
> HU - Surface: Pendant - 2.0hrs (MC) LV 20ft
|
||||
> HU - Surface: J-Box For Future Fixture (MC) LV 20ft
|
||||
> HU - Recessed (MC) LV 20ft
|
||||
> *** Condo Units ***
|
||||
> CU - Surface: Tape - 1.0hrs (MC) LV 25ft
|
||||
> CU - Surface: Wall (MC) LV 25ft
|
||||
> ```
|
||||
|
||||
## Fixture Labor
|
||||
|
||||
> | Fixture Type | Labor |
|
||||
> | ------------ | -------------- |
|
||||
@@ -15,7 +41,7 @@
|
||||
>
|
||||
> [^1]: Determine exact labor from fixture and size.
|
||||
|
||||
### Fixture Branch Length
|
||||
## Fixture Branch Length
|
||||
|
||||
> | Case | Standard Length |
|
||||
> | ------------- | --------------- |
|
||||
@@ -32,7 +58,7 @@
|
||||
>
|
||||
> [^2]: See fixture types below for special cases.
|
||||
|
||||
### Fixture Branch Wire size
|
||||
## Fixture Branch Wire size
|
||||
|
||||
> | Case | Wire Size |
|
||||
> | -------------- | --------- |
|
||||
@@ -45,9 +71,9 @@
|
||||
>
|
||||
> [^2]: Kitchen and bathroom fixtures shall be #12 (NOT #14) on wood frame (NM) projects.
|
||||
|
||||
### Garage
|
||||
## Garage
|
||||
|
||||
#### Fixtures
|
||||
### Fixtures
|
||||
|
||||
Use ENT Assembly unless spec requires otherwise.
|
||||
|
||||
@@ -61,7 +87,7 @@ If PVC, use following assemblies:
|
||||
| Ceiling | `PVC/ENT ASSEMBLIES`/`... - SLAB BOX / 45 DEG STUBBY` |
|
||||
| Wall | `PVC/ENT ASSEMBLIES`/`... - STL BOX & TILE RING / 45 DEG STUBBY/ ENT DROP` |
|
||||
|
||||
#### Homeruns
|
||||
### Homeruns
|
||||
|
||||
> `System` = "EL - Electrical"
|
||||
|
||||
@@ -69,7 +95,7 @@ Use 1 Homerun for every 3 circuits in Garage
|
||||
|
||||
Use assembly `Common Assemblies`/`Device Homeruns in Slab/Deck`
|
||||
|
||||
### Surface Mount
|
||||
## Surface Mount
|
||||
|
||||
* Wall Mount (Sconce)
|
||||
* Pendant
|
||||
@@ -88,7 +114,7 @@ Use assembly `Common Assemblies`/`Device Homeruns in Slab/Deck`
|
||||
> [!note]
|
||||
> Use lighting control cable assemblies in Amenity areas
|
||||
|
||||
#### Tape Lighting
|
||||
### Tape Lighting
|
||||
|
||||
Also called "cove" or "strip",
|
||||
however those terms are less specific
|
||||
@@ -128,7 +154,7 @@ A - Tape 9.5hr (109-114ft) - MC #12 40ft
|
||||
A - Tape 10.0hr (115-120ft) - MC #12 40ft
|
||||
```
|
||||
|
||||
### Recessed
|
||||
## Recessed
|
||||
|
||||
* recessed downlight
|
||||
* recessed linear
|
||||
@@ -147,7 +173,7 @@ round up to the nearest 5ft
|
||||
> [!note]
|
||||
> "HI HAT" refers to a recessed can fixture.
|
||||
|
||||
### Undercabinet Fixtures
|
||||
## Undercabinet Fixtures
|
||||
|
||||
| Wiring Method | Assembly Path |
|
||||
| ------------- | ------------------------------------- |
|
||||
@@ -159,7 +185,7 @@ round up to the nearest 5ft
|
||||
|
||||
Use 10ft #12/2 for MC & NM
|
||||
|
||||
### Paddle Fans
|
||||
## Paddle Fans
|
||||
|
||||
| Wiring Method | Assembly Path |
|
||||
| ------------- | ----------------------------------------------------- |
|
||||
@@ -167,11 +193,11 @@ Use 10ft #12/2 for MC & NM
|
||||
| MC Cable | `MC ASSEMBLIES`/`FAN RATED OCT BOX W/ BAR HNGR - ...` |
|
||||
| PVC | `PVC/ENT ASSEMBLIES`/`... - SLAB BOX / 45 DEG STUBBY` |
|
||||
|
||||
### Stairwells & Elevators
|
||||
## Stairwells & Elevators
|
||||
|
||||
`PVC/ENT ASSEMBLIES`/`... - SLAB BOX / 45 DEG STUBBY`
|
||||
|
||||
### Facade
|
||||
## Facade
|
||||
|
||||
> `Phase` = "Facade"
|
||||
|
||||
@@ -185,24 +211,24 @@ Length and Labor will be more than a normal fixture in BOH/Amenity
|
||||
> 1. `3/4" PVC W/ 3#10 - STL BOX & TILE RING / 45 DEG STUBBY/ ENT DROP`
|
||||
> * `Length per Unit` = Distance to panel
|
||||
|
||||
### Porte Cochere (Drive up Area)
|
||||
## Porte Cochere (Drive up Area)
|
||||
|
||||
Create its own breakout in WBS, and phase in Accubid
|
||||
|
||||
This is not technically exposed or drop ceiling, but still use PVC
|
||||
|
||||
### FAA Lighting
|
||||
## FAA Lighting
|
||||
|
||||
> 1. `FIXTURE LABOR`/`FIXTURE LABOR 1HR`
|
||||
> 2. `FESTOON & ROOF ASSEMBLIES`/`Aircraft Warning, 3/4" Conduit GRC/PVC 2#10, 1#10G`
|
||||
|
||||
## Site & Courtyard
|
||||
# Site & Courtyard
|
||||
|
||||
### Breakdowns
|
||||
## Breakdowns
|
||||
|
||||
> `System` = "FML - Site Fixtures Material & Labor"
|
||||
|
||||
### Fixture Assemblies
|
||||
## Fixture Assemblies
|
||||
|
||||
> | Fixture Type | Assembly Path |
|
||||
> | ------------------------------------ | -------------------------------------------------------------------------------- |
|
||||
@@ -217,7 +243,7 @@ This is not technically exposed or drop ceiling, but still use PVC
|
||||
>
|
||||
> [^2]: Per Corwin: Hand rail lights should have a rigid 90 stub up and some flex
|
||||
|
||||
#### Festoon Lighting
|
||||
### Festoon Lighting
|
||||
|
||||
AKA "string" or "market" lights
|
||||
|
||||
|
||||