@@ -12,6 +12,22 @@ All control methods are likely to appear in drawings.
|
|||||||
> [!info] "Local Control"
|
> [!info] "Local Control"
|
||||||
> The term "local control only" is sometimes used to indicate no condiseration
|
> The term "local control only" is sometimes used to indicate no condiseration
|
||||||
> for *any* lighting control beyond standard devices,
|
> for *any* lighting control beyond standard devices,
|
||||||
> (with dimmers being the triac type)
|
> (with $Ds being the triac type)
|
||||||
> however, this phrasing is ambiguous and non-universal.
|
> however, this phrasing is ambiguous and non-universal.
|
||||||
> Confirm with the bid team on what must be included.
|
> Confirm with the bid team on what must be included.
|
||||||
|
|
||||||
|
## Custom Switch Boxes
|
||||||
|
|
||||||
|
For switch combinations not in `COMMON ASSEMBLIES`,
|
||||||
|
create heating designations based on the most similar.
|
||||||
|
|
||||||
|
### Naming
|
||||||
|
|
||||||
|
#### Format
|
||||||
|
|
||||||
|
```regex
|
||||||
|
<phase-abbr> - <assembly>(\: <subtype>)?( - <fixture-labor>)? \(<wiring-method>\)( <wm-descriptor>)* <branch-length>ft
|
||||||
|
```
|
||||||
|
|
||||||
|
> [!example]
|
||||||
|
> `A - Surface: Pendant - 2.0hrs (MC) LV 20ft`
|
||||||
|
|||||||
@@ -1,8 +1,34 @@
|
|||||||
# Lighting Takeoff
|
# Lighting Takeoff (Fixtures)
|
||||||
|
|
||||||
## Fixtures
|
## Naming
|
||||||
|
|
||||||
### Fixture Labor
|
### Format
|
||||||
|
|
||||||
|
```regex
|
||||||
|
<phase-abbr> - <assembly>(\: <subtype>)?( - <fixture-labor>)? \(<wiring-method>\)( <wm-descriptor>)* <branch-length>ft
|
||||||
|
```
|
||||||
|
|
||||||
|
> [!example]
|
||||||
|
> `A - Surface: Pendant - 2.0hrs (MC) LV 20ft`
|
||||||
|
|
||||||
|
### Order
|
||||||
|
|
||||||
|
Use empty designations to separate phases.
|
||||||
|
|
||||||
|
> [!example]
|
||||||
|
> ```
|
||||||
|
> *** Hotel Units ***
|
||||||
|
> HU - Surface (MC) LV 20ft
|
||||||
|
> HU - Surface - 1.5hrs (MC) LV 20ft
|
||||||
|
> HU - Surface: Pendant - 2.0hrs (MC) LV 20ft
|
||||||
|
> HU - Surface: J-Box For Future Fixture (MC) LV 20ft
|
||||||
|
> HU - Recessed (MC) LV 20ft
|
||||||
|
> *** Condo Units ***
|
||||||
|
> CU - Surface: Tape - 1.0hrs (MC) LV 25ft
|
||||||
|
> CU - Surface: Wall (MC) LV 25ft
|
||||||
|
> ```
|
||||||
|
|
||||||
|
## Fixture Labor
|
||||||
|
|
||||||
> | Fixture Type | Labor |
|
> | Fixture Type | Labor |
|
||||||
> | ------------ | -------------- |
|
> | ------------ | -------------- |
|
||||||
@@ -15,7 +41,7 @@
|
|||||||
>
|
>
|
||||||
> [^1]: Determine exact labor from fixture and size.
|
> [^1]: Determine exact labor from fixture and size.
|
||||||
|
|
||||||
### Fixture Branch Length
|
## Fixture Branch Length
|
||||||
|
|
||||||
> | Case | Standard Length |
|
> | Case | Standard Length |
|
||||||
> | ------------- | --------------- |
|
> | ------------- | --------------- |
|
||||||
@@ -32,7 +58,7 @@
|
|||||||
>
|
>
|
||||||
> [^2]: See fixture types below for special cases.
|
> [^2]: See fixture types below for special cases.
|
||||||
|
|
||||||
### Fixture Branch Wire size
|
## Fixture Branch Wire size
|
||||||
|
|
||||||
> | Case | Wire Size |
|
> | Case | Wire Size |
|
||||||
> | -------------- | --------- |
|
> | -------------- | --------- |
|
||||||
@@ -45,9 +71,9 @@
|
|||||||
>
|
>
|
||||||
> [^2]: Kitchen and bathroom fixtures shall be #12 (NOT #14) on wood frame (NM) projects.
|
> [^2]: Kitchen and bathroom fixtures shall be #12 (NOT #14) on wood frame (NM) projects.
|
||||||
|
|
||||||
### Garage
|
## Garage
|
||||||
|
|
||||||
#### Fixtures
|
### Fixtures
|
||||||
|
|
||||||
Use ENT Assembly unless spec requires otherwise.
|
Use ENT Assembly unless spec requires otherwise.
|
||||||
|
|
||||||
@@ -61,7 +87,7 @@ If PVC, use following assemblies:
|
|||||||
| Ceiling | `PVC/ENT ASSEMBLIES`/`... - SLAB BOX / 45 DEG STUBBY` |
|
| Ceiling | `PVC/ENT ASSEMBLIES`/`... - SLAB BOX / 45 DEG STUBBY` |
|
||||||
| Wall | `PVC/ENT ASSEMBLIES`/`... - STL BOX & TILE RING / 45 DEG STUBBY/ ENT DROP` |
|
| Wall | `PVC/ENT ASSEMBLIES`/`... - STL BOX & TILE RING / 45 DEG STUBBY/ ENT DROP` |
|
||||||
|
|
||||||
#### Homeruns
|
### Homeruns
|
||||||
|
|
||||||
> `System` = "EL - Electrical"
|
> `System` = "EL - Electrical"
|
||||||
|
|
||||||
@@ -69,7 +95,7 @@ Use 1 Homerun for every 3 circuits in Garage
|
|||||||
|
|
||||||
Use assembly `Common Assemblies`/`Device Homeruns in Slab/Deck`
|
Use assembly `Common Assemblies`/`Device Homeruns in Slab/Deck`
|
||||||
|
|
||||||
### Surface Mount
|
## Surface Mount
|
||||||
|
|
||||||
* Wall Mount (Sconce)
|
* Wall Mount (Sconce)
|
||||||
* Pendant
|
* Pendant
|
||||||
@@ -88,7 +114,7 @@ Use assembly `Common Assemblies`/`Device Homeruns in Slab/Deck`
|
|||||||
> [!note]
|
> [!note]
|
||||||
> Use lighting control cable assemblies in Amenity areas
|
> Use lighting control cable assemblies in Amenity areas
|
||||||
|
|
||||||
#### Tape Lighting
|
### Tape Lighting
|
||||||
|
|
||||||
Also called "cove" or "strip",
|
Also called "cove" or "strip",
|
||||||
however those terms are less specific
|
however those terms are less specific
|
||||||
@@ -128,7 +154,7 @@ A - Tape 9.5hr (109-114ft) - MC #12 40ft
|
|||||||
A - Tape 10.0hr (115-120ft) - MC #12 40ft
|
A - Tape 10.0hr (115-120ft) - MC #12 40ft
|
||||||
```
|
```
|
||||||
|
|
||||||
### Recessed
|
## Recessed
|
||||||
|
|
||||||
* recessed downlight
|
* recessed downlight
|
||||||
* recessed linear
|
* recessed linear
|
||||||
@@ -147,7 +173,7 @@ round up to the nearest 5ft
|
|||||||
> [!note]
|
> [!note]
|
||||||
> "HI HAT" refers to a recessed can fixture.
|
> "HI HAT" refers to a recessed can fixture.
|
||||||
|
|
||||||
### Undercabinet Fixtures
|
## Undercabinet Fixtures
|
||||||
|
|
||||||
| Wiring Method | Assembly Path |
|
| Wiring Method | Assembly Path |
|
||||||
| ------------- | ------------------------------------- |
|
| ------------- | ------------------------------------- |
|
||||||
@@ -159,7 +185,7 @@ round up to the nearest 5ft
|
|||||||
|
|
||||||
Use 10ft #12/2 for MC & NM
|
Use 10ft #12/2 for MC & NM
|
||||||
|
|
||||||
### Paddle Fans
|
## Paddle Fans
|
||||||
|
|
||||||
| Wiring Method | Assembly Path |
|
| Wiring Method | Assembly Path |
|
||||||
| ------------- | ----------------------------------------------------- |
|
| ------------- | ----------------------------------------------------- |
|
||||||
@@ -167,11 +193,11 @@ Use 10ft #12/2 for MC & NM
|
|||||||
| MC Cable | `MC ASSEMBLIES`/`FAN RATED OCT BOX W/ BAR HNGR - ...` |
|
| MC Cable | `MC ASSEMBLIES`/`FAN RATED OCT BOX W/ BAR HNGR - ...` |
|
||||||
| PVC | `PVC/ENT ASSEMBLIES`/`... - SLAB BOX / 45 DEG STUBBY` |
|
| PVC | `PVC/ENT ASSEMBLIES`/`... - SLAB BOX / 45 DEG STUBBY` |
|
||||||
|
|
||||||
### Stairwells & Elevators
|
## Stairwells & Elevators
|
||||||
|
|
||||||
`PVC/ENT ASSEMBLIES`/`... - SLAB BOX / 45 DEG STUBBY`
|
`PVC/ENT ASSEMBLIES`/`... - SLAB BOX / 45 DEG STUBBY`
|
||||||
|
|
||||||
### Facade
|
## Facade
|
||||||
|
|
||||||
> `Phase` = "Facade"
|
> `Phase` = "Facade"
|
||||||
|
|
||||||
@@ -185,24 +211,24 @@ Length and Labor will be more than a normal fixture in BOH/Amenity
|
|||||||
> 1. `3/4" PVC W/ 3#10 - STL BOX & TILE RING / 45 DEG STUBBY/ ENT DROP`
|
> 1. `3/4" PVC W/ 3#10 - STL BOX & TILE RING / 45 DEG STUBBY/ ENT DROP`
|
||||||
> * `Length per Unit` = Distance to panel
|
> * `Length per Unit` = Distance to panel
|
||||||
|
|
||||||
### Porte Cochere (Drive up Area)
|
## Porte Cochere (Drive up Area)
|
||||||
|
|
||||||
Create its own breakout in WBS, and phase in Accubid
|
Create its own breakout in WBS, and phase in Accubid
|
||||||
|
|
||||||
This is not technically exposed or drop ceiling, but still use PVC
|
This is not technically exposed or drop ceiling, but still use PVC
|
||||||
|
|
||||||
### FAA Lighting
|
## FAA Lighting
|
||||||
|
|
||||||
> 1. `FIXTURE LABOR`/`FIXTURE LABOR 1HR`
|
> 1. `FIXTURE LABOR`/`FIXTURE LABOR 1HR`
|
||||||
> 2. `FESTOON & ROOF ASSEMBLIES`/`Aircraft Warning, 3/4" Conduit GRC/PVC 2#10, 1#10G`
|
> 2. `FESTOON & ROOF ASSEMBLIES`/`Aircraft Warning, 3/4" Conduit GRC/PVC 2#10, 1#10G`
|
||||||
|
|
||||||
## Site & Courtyard
|
# Site & Courtyard
|
||||||
|
|
||||||
### Breakdowns
|
## Breakdowns
|
||||||
|
|
||||||
> `System` = "FML - Site Fixtures Material & Labor"
|
> `System` = "FML - Site Fixtures Material & Labor"
|
||||||
|
|
||||||
### Fixture Assemblies
|
## Fixture Assemblies
|
||||||
|
|
||||||
> | Fixture Type | Assembly Path |
|
> | Fixture Type | Assembly Path |
|
||||||
> | ------------------------------------ | -------------------------------------------------------------------------------- |
|
> | ------------------------------------ | -------------------------------------------------------------------------------- |
|
||||||
@@ -217,7 +243,7 @@ This is not technically exposed or drop ceiling, but still use PVC
|
|||||||
>
|
>
|
||||||
> [^2]: Per Corwin: Hand rail lights should have a rigid 90 stub up and some flex
|
> [^2]: Per Corwin: Hand rail lights should have a rigid 90 stub up and some flex
|
||||||
|
|
||||||
#### Festoon Lighting
|
### Festoon Lighting
|
||||||
|
|
||||||
AKA "string" or "market" lights
|
AKA "string" or "market" lights
|
||||||
|
|
||||||
|
|||||||