"basename": "open-problems-in-estimating", "basename": "open-problems-in-estimating",
"path": "open-problems-in-estimating.md" "path": "open-problems-in-estimating.md"
@@ -8,14 +28,6 @@
"basename": "portable-tools", "basename": "portable-tools",
"path": "portable-tools.md" "path": "portable-tools.md"
}, },
{
"basename": "README",
"path": "README.md"
},
{
"basename": "feeders",
"path": "feeders.md"
},
{ {
"basename": "low-voltage", "basename": "low-voltage",
"path": "low-voltage.md" "path": "low-voltage.md"
@@ -28,10 +40,6 @@
"basename": "electrical", "basename": "electrical",
"path": "electrical.md" "path": "electrical.md"
}, },
{
"basename": "full-takeoff",
"path": "full-takeoff.md"
},
{ {
"basename": "feeder-sizing", "basename": "feeder-sizing",
"path": "feeder-sizing.md" "path": "feeder-sizing.md"
@@ -60,10 +68,6 @@
"basename": "assembly-objects", "basename": "assembly-objects",
"path": "assembly-objects.md" "path": "assembly-objects.md"
}, },
{
"basename": "switchgear",
"path": "switchgear.md"
},
{ {
"basename": "bpm-award-analysis", "basename": "bpm-award-analysis",
"path": "bpm-award-analysis.md" "path": "bpm-award-analysis.md"
@@ -195,10 +199,6 @@
{ {
"basename": "blank-system", "basename": "blank-system",
"path": "blank-system.md" "path": "blank-system.md"
},
{
"basename": "subfeeds",
"path": "subfeeds.md"
} }
], ],
"omittedPaths": [], "omittedPaths": [],
+12 -6
View File
@@ -68,12 +68,14 @@ Locate:
> All takeoffs in Systems with names including "site" > All takeoffs in Systems with names including "site"
> should be in "Site" Area, Phase, and Bid Item breakdowns. > should be in "Site" Area, Phase, and Bid Item breakdowns.
For adjacent panels, use a minimum 10ft length.
#### Adders #### Adders
Use the difference in elevation between equipment Use the difference in elevation between equipment
or 10ft, whichever is greater. or 10ft, whichever is greater.
Add an additional 5ft for site runs Add an additional 5ft (total 15ft) for site runs
(primaries, secondaries, etc.). (primaries, secondaries, etc.).
#### Primaries #### Primaries
@@ -82,14 +84,18 @@ Empty conduit.
#### Secondaries #### Secondaries
> [!info] Vaults and Secondary Connections ##### Wiring on Vault Racks
> In utility vaults, secondary conductors sometimes run on racks,
> far past their entrance conduits, to their transformers. Where secondary conductors run on racks in utility vaults
> It is necessary to add this distance to the wire makeup, manually set the length of conduit,
> rather than simply measure the conduit assembly to the transformer. measure the wire length,
add 20ft in addition to previously mentioned adders.
#### Feeders #### Feeders
`Area` = "01 - Feeders/Risers Building"
for all feeders, no matter the location.
#### Bus Duct #### Bus Duct
`COMMON ASSEMBLIES`/`DISTRIBUTION`/`BUS DUCT` `COMMON ASSEMBLIES`/`DISTRIBUTION`/`BUS DUCT`
+2
View File
@@ -35,3 +35,5 @@ Complete [[project-setup]].
11. [[misc-budgets]] 11. [[misc-budgets]]
### 3. Extension (Review and Checking) ### 3. Extension (Review and Checking)
1. [[material-pricing]]
+43
View File
@@ -0,0 +1,43 @@
---
id:
aliases: []
tags:
- occupational
---
# Material Pricing
## Info
Use PDI and another vendor per the table below.
PDI pricing takes precedence where available.
| State | Vendor |
| ----- | ----------------------------- |
| AZ | QED INC - 12535 |
| CA | QED INC - 12535 |
| CO | QED INC - 12535 |
| DC | CAPITAL ELECTRIC - 14302 |
| DE | CAPITAL ELECTRIC - 14302 |
| FL | WORLD ELECTRIC SUPPLY - 45223 |
| GA | WORLD ELECTRIC SUPPLY - 34243 |
| MD | CAPITAL ELECTRIC - 14302 |
| NC | WORLD ELECTRIC SUPPLY - 34243 |
| NJ | COOPER ELECTRIC - 34860 |
| NY | COOPER ELECTRIC - 34860 |
| PA | CAPITAL ELECTRIC - 14302 |
| SC | WORLD ELECTRIC SUPPLY - 34243 |
| TN | WORLD ELECTRIC SUPPLY - 34243 |
| TX | QED INC - 12535 |
| VA | CAPITAL ELECTRIC - 14302 |
| WA | QED INC - 12535 |
> [!important]
> When updating, uncheck Update Supplier Code.
## Sequence
### 1. Estimate preparation
### 2. Takeoff
### 3. Extension (Review and Checking)
+9 -2
View File
@@ -14,7 +14,7 @@ tags:
2. In the drawings, locate: 2. In the drawings, locate:
* Riser Diagrams * Riser Diagrams
* House Panels * House Panels
3. Copy over default Temporary Assemblies from ? 3. Copy over default Temporary Assemblies from sandbox job
### 2. Takeoff ### 2. Takeoff
@@ -38,7 +38,6 @@ tags:
* Meter * Meter
* Fire Pump * Fire Pump
* Fire Pump Controller * Fire Pump Controller
* SPD/TVSS
When building panelboards/switchboards, When building panelboards/switchboards,
add terminations according to an example from the schedules. add terminations according to an example from the schedules.
@@ -52,6 +51,14 @@ Items to Avoid:
* Grounding * Grounding
* Elevator Room * Elevator Room
#### SPD's/TVSS's
Labor only: ~1.5hrs
#### Panelboards
`DISTRIBUTION`/`DIST PANELS & UNIT LOAD CENTERS`/...
#### Enclosed Circuit Breakers #### Enclosed Circuit Breakers
Treat as disconnect switch. Treat as disconnect switch.