# Distribution Designations
|
|
|
|
## Naming
|
|
|
|
> [!example]
|
|
> ```
|
|
> Generator - 350kW, Diesel
|
|
> Generator - 2000kW, Diesel
|
|
> ATS - 200A
|
|
> ATS - 250A
|
|
> ATS - 400A
|
|
> ATS - 600A
|
|
> ATS - 800A
|
|
> ATS - 1000A
|
|
> Panelboard - 50A, 1-Section
|
|
> Panelboard - 100A, 1-Section
|
|
> Panelboard - 125A, 1-Section
|
|
> Panelboard - 150A, 1-Section
|
|
> Panelboard - 225A, 1-Section
|
|
> Panelboard - 225A, 2-Section
|
|
> Panelboard - 400A, 1-Section
|
|
> Panelboard - 400A, 2-Section
|
|
> Panelboard - 400A, 3-Section
|
|
> Panelboard - 600A, 2-Section
|
|
> Panelboard - 800A, 1-Section
|
|
> Panelboard - 1200A, 1-Section
|
|
> Panelboard - 1200A, 2-Section
|
|
> Panelboard - 3000A, 1-Section
|
|
> CT Cabinet
|
|
> Power Monitor
|
|
> SPD/TVSS
|
|
> ```
|
|
|
|
## Content
|
|
|
|
### Terminations
|
|
|
|
When building
|
|
* [[#Panelboards]]
|
|
* [[#Switchboards]]
|
|
add **branch terminations** according to an example from the schedules.
|
|
**Do not include feeder terminations.**
|
|
|
|
## By Equipment Type
|
|
|
|
> [!tip] When in Doubt
|
|
> If the equipment is not listed below,
|
|
> use a distribution panel of equal amps.
|
|
|
|
### CT Cabinets
|
|
|
|
???
|
|
|
|
### SPD's/TVSS's
|
|
|
|
> Name = "SPD"
|
|
|
|
Labor only.
|
|
|
|
Specific item is not important, but I use
|
|
`SPLITTERS / SOCKETS / CABINETS`/`METER SOCKETS & CABINETS`/`METERING CURRENT TRANSFORMER`
|
|
(Labor = 1.5hrs)
|
|
for consistency.
|
|
|
|
### Submeters/Power Monitors
|
|
|
|
> Name = "Power Monitor"
|
|
|
|
See [[switchgear#SPD's/TVSS's]]
|
|
|
|
### Switchboards
|
|
|
|
> Name = "Switchboard - 2000A, 4-Section"
|
|
|
|
### Panelboards
|
|
|
|
> Name = "Panelboard - 600A, 2-Section"
|
|
|
|
`DISTRIBUTION`/`DIST PANELS & UNIT LOAD CENTERS`/...
|
|
|
|
### Disconnects and Enclosed Circuit Breakers
|
|
|
|
`COMMON ASSEMBLIES`/`DISTRIBUTION`/`MANUAL DISCONNECTS`/...
|
|
|
|
### Generators
|
|
|
|
> Name = "Generator - 250kW, Diesel"
|
|
|
|
Add `DISTRIBUTION FITTINGS`/`GENERATOR SET UP`.
|
|
|
|
### Generator Connection Cabinets
|
|
|
|
> Name = "GCC - 200A"
|
|
|
|
Use a Distribution Panel of equal amps.
|
|
Or a transfer switch.
|
|
|
|
### Transfer Switches
|
|
|
|
> Name = "Transfer Switch - 400A"
|
|
|
|
#### Transfer Switches 1200A+
|
|
|
|
Use 1200A and add an additional `TRANSFER SWITCH` item
|
|
to make up the remaining amps.
|
|
|
|
### Meter Centers
|
|
|
|
> Name = "Meter Center - 800A, 16-Can"
|
|
|
|
`SWITCHGEAR & METER CENTERS`/`METER CENTERS`/`... METERING SECTION`
|
|
|
|
Adjust Factor 1 for meter stacks, delete zeroed items.
|