# Distributed Antenna Systems (DAS) Takeoff
|
|
|
|
> [!important]
|
|
> Complete [[emergency-systems-research]] before beginning takeoff.
|
|
|
|
> [!info]
|
|
> See [[emergency-communications-systems]] for information
|
|
> about Emergency Responder Radio Communication Systems (ERRCS).
|
|
|
|
> [!info] Cellular Systems
|
|
> Less common than ERRCS are "cellular DAS" systems
|
|
|
|
`COMMON ASSEMBLIES`/`FIRE ALARM & DAS SYSTEMS`/`DAS ASSEMBLIES`/...
|
|
|
|
## Backbone
|
|
|
|
### FACR to Every Elevator Shaft
|
|
|
|
1. .../`FACR TO ELEV PIT = ...`
|
|
* **Length** = _Match Fire Alarm takeoff Length_
|
|
* **Count** = _Match Fire Alarm takeoff Count_
|
|
|
|
### FACR to Every Staircase
|
|
|
|
1. .../`FACR TO STAIRWELL = ...`
|
|
* **Length** = _Match Fire Alarm takeoff Length_
|
|
* **Count** = _Match Fire Alarm takeoff Count_
|
|
|
|
### Stairwell Riser Every 2 Floors
|
|
|
|
1. * `Area` = "Typical - Stairwells Building Even Levels"
|
|
|
|
.../`STAIRWELL RISER EVERY 2 FLRS = ...`
|
|
* **Count** = Each stairwell
|
|
|
|
### FACR to Electric Room
|
|
|
|
1. .../`FACR TO 2HR-RATED RM = ...`
|
|
* **Length** = _Match Fire Alarm Terminal Cabinet takeoff Length_
|
|
|
|
### Electric Room Riser to Every Floor
|
|
|
|
1. .../`2HR-RATED RM RISER TO EVERY FLR = ...`
|
|
* **Count** = Each Electric Room
|
|
|
|
### Top 2H Rated Room To Roof
|
|
|
|
1. .../`TOP 2HR RATED RM TO ROOF = ...`
|
|
* **Length** = Top level ceiling height to structure (minimum 15ft)
|
|
|
|
## Horizontal
|
|
|
|
> [!important]
|
|
> Usually only for cellular DAS.
|
|
> Confirm takeoff requirement with [[pdi-estimating#Bid Estimating|Bid]].
|
|
|
|
1. .../`CORRIDORS ...`
|
|
* **Length** = Length measured for every corridor/garage
|