# IBC Construction Types
The International Building Code (IBC)
lists 5 major construction types based on fire ratings/materials.
## 5-Over-1 Construction
"5-over-1" construction denotes a building
with levels of combustible construction
above levels of non-combustible construction.
buildings with two non-combustible levels (5-over-2)
and Type III upper floors (3-over-1)
are also common,
though "5-over-1" denotes the general practice.
## Type I: Fire Resistive Non-Combustible
Building elements are noncombustible[^1]
[^1]: Defined as passing the test procedures
for defining combustibility of elementary materials
set forth in ASTM E 136
* Concrete, masonry, noncombustible steel
### Type I-A: Protected Fire-Resistive Non-Combustible
Common of [[pdi-building-types#High Rise]] and Group I occupancies.
* 3hr Exterior Walls
* 3hr Structural Frame
* 2hr Floor/Ceiling Assembly
* 1.5hr Roof Protection
### Type I-B: Unprotected Fire-Resistive Non-Combustible
Common of mid-rise office & Group R buildings.
* 2hr Exterior Walls
* 2hr Structural Frame
* 2hr Ceiling/Floor Separation
* 1hr Ceiling/Roof Assembly
## Type II: Non-Combustible
Same materials as [[#Type I Fire-Resistive Non-Combustible]],
with reduced fire-resistance requirements.
Common of [[pdi-building-types#Mid Rise]] buildings.
### Type II-A: Protected Non-Combustible
Common of [[pdi-building-types#High Density]],
including dormitory buildings.
* 1hr Exterior Walls
* 1hr Structural Frame
* 1hr Floor/Ceiling/Roof Protection
### Type II-B: Unprotected Non-Combustible
Common of [[pdi-building-types#Commercial]].
## Type III: Combustible
Also known as "ordinary" construction.
Exterior walls are of noncombustible materials.
Interior building elements may be combustible.
### Type III-A: Protected Combustible
Common of [[pdi-building-types#High Density]].
* 2hr Exterior Walls
* 1hr Structural Frame
* 1hr Floor/Ceiling/Roof Protection
### Type III-B: Unprotected Combustible
Common of "warehouse" districts of older cities.
* 2hr Exterior Walls
## Type IV: Heavy Timber
Also known as "mill" construction.
Exterior walls are of noncombustible materials.
Interior building elements are of solid or laminated wooden members
with a minimum nominal dimension of 8 inches
without concealed spaces.
* 2hr Exterior Walls
* 1hr Structural Frame or Heavy Timber Heavy Timber Floor/Ceiling/Roof Assemblies
## Type V: Wood Frame
Construction materials are of any allowed by code,
combustible or noncombustible.
Common of garden or above podiums
### Type V-A: Protected Wood Frame
Commonly used in the construction of newer apartment buildings.
There is no exposed wood visible.
* 1hr Exterior Walls
* 1hr Structural Frame 1hr Floor/Ceiling/Roof
### Type V-B: Unprotected Wood Frame
Common of single family homes.