vault backup: 2026-03-09 16:50:11
This commit is contained in:
@@ -23,9 +23,15 @@ Policy Number: ATH1143034
|
|||||||
|
|
||||||
Flood Insurance:
|
Flood Insurance:
|
||||||
Insurer: [National General](https://eservice.nationalgeneral.com/)
|
Insurer: [National General](https://eservice.nationalgeneral.com/)
|
||||||
Policy Number: 0003457855]
|
Policy Number: 0003457855
|
||||||
|
|
||||||
## Contractors
|
## Resources
|
||||||
|
|
||||||
|
### Websites
|
||||||
|
|
||||||
|
[South Florida Plant Guide](https://www.south-florida-plant-guide.com/)
|
||||||
|
|
||||||
|
### Contractors
|
||||||
|
|
||||||
* **HVAC:** Agape Air (semiannual service)
|
* **HVAC:** Agape Air (semiannual service)
|
||||||
* **Plumbing:** Hafke Plumbing
|
* **Plumbing:** Hafke Plumbing
|
||||||
|
|||||||
@@ -0,0 +1,190 @@
|
|||||||
|
---
|
||||||
|
id: 2026-03-09T15:50:49-04:00
|
||||||
|
aliases: []
|
||||||
|
title: 2026-03-09 15:50:49
|
||||||
|
tags:
|
||||||
|
- authorship/original
|
||||||
|
- destiny/permanent
|
||||||
|
- status/draft
|
||||||
|
- type/timestamped
|
||||||
|
daily: "[[2026-03-09]]"
|
||||||
|
date-created: 2026-03-09T15:50:49-04:00
|
||||||
|
dg-publish: true
|
||||||
|
monthly: "[[2026-03]]"
|
||||||
|
quarterly: "[[2026-Q1]]"
|
||||||
|
weekly: "[[2026-W11]]"
|
||||||
|
yearly: "[[2026]]"
|
||||||
|
---
|
||||||
|
# 2026-03-09 15:50:49
|
||||||
|
|
||||||
|
%% Implementation of [[conest-pre-takeoff-email-template]] %%
|
||||||
|
|
||||||
|
Hello Team,
|
||||||
|
|
||||||
|
Below is a comprehensive list of means & methods for Charlotte South End Hotel.
|
||||||
|
Please confirm you have received this email and respond with any questions or comments.
|
||||||
|
|
||||||
|
* **Delivery Method:** Plans & Specs
|
||||||
|
* **Document Stage:** Issue for Permit
|
||||||
|
* **Drawings Date:** 2026-02-27
|
||||||
|
* **Project Manual Date:** 2026-02-27
|
||||||
|
* **Proposal Date:** 2025-12-12
|
||||||
|
* **Takeoff Request Stage:** Full Takeoff
|
||||||
|
|
||||||
|
### Project Specification Callouts
|
||||||
|
|
||||||
|
* **Conduit:**
|
||||||
|
%% GRC, coupling specs, etc. %%
|
||||||
|
|
||||||
|
* **Wire:**
|
||||||
|
* Material: Aluminum 100A and larger _---E021 "ALUMINUM FEEDER SCHEDULE" Note 1(b)_
|
||||||
|
* Acceptable Manufacturers: _---Spec 260510-2 (p. 2224)_
|
||||||
|
* Encore Wire
|
||||||
|
* General Cable
|
||||||
|
* Okonite
|
||||||
|
* Paranite
|
||||||
|
* Pirelli
|
||||||
|
* Senator
|
||||||
|
* Southwire
|
||||||
|
|
||||||
|
* **MC Cable:**
|
||||||
|
* Application: Concealed feeders and branch circuits _---Spec XXXXXX (p. XXXX)_
|
||||||
|
%% Branch homeruns only; Not permitted %%
|
||||||
|
* Acceptable Manufacturers: _---Spec 260510-2 (p. 2224)_
|
||||||
|
* Alflex
|
||||||
|
* AFC
|
||||||
|
* America Metal Moulding
|
||||||
|
* Encore Wire
|
||||||
|
* Southwire
|
||||||
|
* ==Conductors: Copper _---Spec XXXXXX (p. XXXX)_==
|
||||||
|
* ==Armor: Steel _---Spec XXXXXX (p. XXXX)_==
|
||||||
|
* ==Jacket: PVC _---Spec XXXXXX (p. XXXX)_==
|
||||||
|
|
||||||
|
* **Steel Box Depth:**
|
||||||
|
* Telecom: 2-1/8" _---Spec XXXXXX (p. XXXX)_
|
||||||
|
* Security: 2-1/8" _---Spec XXXXXX (p. XXXX)_
|
||||||
|
* Other Applications: Not specified
|
||||||
|
%% 1-1/2", 2-1/8" %%
|
||||||
|
|
||||||
|
* **Floor Boxes:** Sheet metal with brass or aluminum covers _---Spec XXXXXX (p. XXXX)_
|
||||||
|
|
||||||
|
* **Wiring Devices:**
|
||||||
|
* Units:
|
||||||
|
* Current rating: Unspecified. Assuming 15A for takeoff.
|
||||||
|
* Standard/Decora: Unspecified. Assuming Toggle/Duplex for takeoff.
|
||||||
|
%% 15A Decora %%
|
||||||
|
* BOH/Common Areas:
|
||||||
|
* Current rating: Unspecified. Assuming 20A for takeoff.
|
||||||
|
* Standard/Decora: Unspecified. Assuming Toggle/Duplex for takeoff.
|
||||||
|
%% 20A Toggle/Duplex %%
|
||||||
|
|
||||||
|
* **Switchboards:**
|
||||||
|
* Acceptable Manufacturers: _---Spec XXXXXX (p. XXXX)_
|
||||||
|
* ???
|
||||||
|
* Bus Material: ??? _---Spec XXXXXX (p. XXXX)_
|
||||||
|
* Interrupting Current Rating: ???
|
||||||
|
|
||||||
|
* **Distribution Panelboards:**
|
||||||
|
* Acceptable Manufacturers: _---Spec XXXXXX (p. XXXX)_
|
||||||
|
* ???
|
||||||
|
* Bus Material: ??? _---Spec XXXXXX (p. XXXX)_
|
||||||
|
* Breaker Types: ??? _---Spec XXXXXX (p. XXXX)_
|
||||||
|
%% Snap-on, bolt on %%
|
||||||
|
* Interrupting Current Rating: ???
|
||||||
|
|
||||||
|
* **Load Centers:**
|
||||||
|
* Acceptable Manufacturers: _---Spec XXXXXX (p. XXXX)_
|
||||||
|
* ???
|
||||||
|
* Bus Material: ??? _---Spec XXXXXX (p. XXXX)_
|
||||||
|
* Breaker Types: ??? _---Spec XXXXXX (p. XXXX)_
|
||||||
|
%% Snap-on, bolt on %%
|
||||||
|
* Interrupting Current Rating: ???
|
||||||
|
|
||||||
|
* **Transformers:**
|
||||||
|
* Winding Material: ??? _---Spec XXXXXX (p. XXXX)_
|
||||||
|
* K-Rating: ???
|
||||||
|
%% Windings AL or CU, K-rating %%
|
||||||
|
|
||||||
|
* **Generator:** (1) 500kW Diesel
|
||||||
|
* Enclosure Specs: ??? _---Dwg. E014_
|
||||||
|
* Remote Tank: ???
|
||||||
|
* Tank Size: ??? _---Spec XXXXXX (p. XXXX)_
|
||||||
|
* Load Banks: ??? _---Spec XXXXXX (p. XXXX)_
|
||||||
|
* Acceptable Manufacturers: _---Spec 263213-3 (p. 2323)_
|
||||||
|
* Caterpillar Tractor Co.
|
||||||
|
* Cummins/Power Generation
|
||||||
|
* Kohler Power Systems (MTU Engine Only)
|
||||||
|
* MTU On-Site Energy
|
||||||
|
|
||||||
|
### Project Drawing/Detail Callouts
|
||||||
|
|
||||||
|
* Describe conflicts between drawings / proposal:
|
||||||
|
%% "Plans show CU feeders, proposal calls for aluminum", Specification grade devices, etc. %%
|
||||||
|
|
||||||
|
* Cost drivers in details not shown elsewhere on plans:
|
||||||
|
|
||||||
|
### PDI System Execution Plan
|
||||||
|
|
||||||
|
* **Primaries:**
|
||||||
|
%% Installation only, (9) 6" PVC %%
|
||||||
|
|
||||||
|
* **Secondaries:**
|
||||||
|
*
|
||||||
|
%% PVC UG, GRC Stub-ups, AL %%
|
||||||
|
|
||||||
|
* **Feeders:**
|
||||||
|
PVC UG, EMT OH;
|
||||||
|
Size and material per E05-10 schedule
|
||||||
|
==(Transformer primaries and secondaries all copper)==
|
||||||
|
%% PVC UG, EMT OH, AL over 100A, 2% VD %%
|
||||||
|
%% Emergency Feeds MI Cable %%
|
||||||
|
|
||||||
|
* **Unit Subfeeds:** ???
|
||||||
|
%% MC OH AL, VD per Chart on E5.01 %%
|
||||||
|
|
||||||
|
* **Units:**
|
||||||
|
* ???
|
||||||
|
%% 15A Decora, Disposals, T-stat, Floor Boxes, Shade Control, Doorbells, Dimmer Switches, etc. %%
|
||||||
|
|
||||||
|
* **Telecom:**
|
||||||
|
* ???
|
||||||
|
%% 42" MSDE, No Cable Homeruns, (1) 1" Back to IDF, CAT6 with Stub-ups %%
|
||||||
|
|
||||||
|
* **EV Chargers:** ???
|
||||||
|
%% (42) Conduit only, (56) Conduit & Wire, (20) Conduit, Wire & Equipment %%
|
||||||
|
|
||||||
|
* **Fire Alarm:** ???
|
||||||
|
%% Free-air where allowed by code. EMT Risers. %%
|
||||||
|
|
||||||
|
* **DAS:** ???
|
||||||
|
%% Conduit only, Per PDI DAS Design %%
|
||||||
|
|
||||||
|
* **Low Voltage:** Free-air where allowed by code.
|
||||||
|
%% Free-air where allowed by code. Stub-ups to accessible ceilings. %%
|
||||||
|
|
||||||
|
### Lighting Control
|
||||||
|
|
||||||
|
* **Basis of Takeoff:** ??? _---???_
|
||||||
|
%% Code Minimum per Energy Code Assigned, P&S, PDI Design %%
|
||||||
|
|
||||||
|
* **Area:** _---Dwg. E06-01 "LIGHTING CONTROL NARRATIVE"_
|
||||||
|
*
|
||||||
|
%% Assign Method to Areas: Line Voltage, Low-Voltage Stand Alone or Centralized System %%
|
||||||
|
|
||||||
|
### Tasks/Quotes Needed for WBS
|
||||||
|
|
||||||
|
%% Delete any completed %%
|
||||||
|
|
||||||
|
* Electrical Constructability Review
|
||||||
|
* Electrical VDC
|
||||||
|
* Coordination Study
|
||||||
|
* DAS Public Safety Raceway Design
|
||||||
|
|
||||||
|
<!--
|
||||||
|
DAS Public Safety Raceway Design is necessary
|
||||||
|
if we own DAS pathways but not the system,
|
||||||
|
since if we own the system,
|
||||||
|
the raceway design will be included in the Systems quote.
|
||||||
|
-->
|
||||||
|
|
||||||
|
Thank you,
|
||||||
Reference in New Issue
Block a user